Results

The pipe run of 150 m eats 2.54 m of head (1.69 m per 100 m). That equals 8.5% of gross head, so 27.5 m remains as net head. At 1.91 m/s the flow sits inside the normal 1–3 m/s band. Keep losses under 10% by choosing an inner diameter of at least 194 mm.
Total head loss
2.54m
8.5% of gross head
Net head
27.5m
from 30 m gross
Friction loss (Darcy)
2.07m
minor losses 0.46 m
Flow velocity
1.91m/s
velocity head 0.186 m
Reynolds number
293,849
turbulent
Friction factor f
0.0149
Colebrook · Swamee–Jain 0.0148
Hazen–Williams check
2.53m
C = 150 · Swamee–Jain 2.53 m
Power at turbine
11.3kW
1 kW lost to the pipe
Smallest diameter meeting the target
194mm
≤ 10% loss
Water-hammer surge
12m
Michaud (gradual closure) · wave speed 300 m/s, 2L/a = 1 s
Peak pressure: static plus surge
4.1bar
choose pipe pressure class above this
Head loss and power across a range of diameters

Diameter options

Inner Ø (mm)Velocity (m/s)Head loss (m)Loss %Net head (m)Power (kW)
978.1279.94100%00
1096.4345.5100%00
1225.1326.4888.3%3.51.5
1374.0715.2150.7%14.86.1
1533.268.9930%218.7
1722.585.1717.2%24.810.2
1932.05310%2711.1
2171.621.735.8%28.311.6
2431.291.023.4%2911.9
2731.030.592%29.412.1
3060.820.351.2%29.712.2
3430.650.210.7%29.812.3
3850.520.120.4%29.912.3

Pipe material reference

MaterialRoughness ε (mm)Hazen–Williams CWave speed (m/s)Loss for your pipe (m)
HDPE / PE1000.0071503002.54
PVC-U0.00151504002.5
GRP / fibreglass0.011455002.56
Steel, new welded0.0451301,1002.76
Steel, old / rusty0.51001,1004.01
Galvanised steel0.151201,1003.19
Ductile iron, cement-lined0.031401,1502.68
Cast iron, unlined0.261001,1003.5
Concrete (smooth–average)0.61201,0004.18
Riveted steel2951,0005.78
  • The roughness figures describe new pipe. Scale, biofilm and corrosion push ε upward with age, and an old steel line may lose double the head of a new one.
  • Treat Hazen–Williams as a rule of thumb: it was fitted to data, and fits only turbulent water flow at everyday temperatures. For a rigorous answer, use Darcy–Weisbach with the Colebrook friction factor.
  • Water-hammer figures rest on a typical pressure-wave speed for the pipe material. The actual speed varies with wall thickness and pipe class. For big schemes, a transient analysis should set the surge protection.