A string of 12 modules passes every check. Cold Voc is 515 V against a 1,100 V limit, and the 335–440 V operating range sits within the 160–1,000 V MPPT window. Permitted range: 6–25.
Modules allowed per string
6 – 25
set by the maximum DC voltage
String Voc at the coldest on record
515V
42.94 V/module at -20 °C (×1.113)
String Vmp, hot cells
335V
cells at 70 °C
String Vmp, cold
440V
MPPT window 160–1,000 V
Max modules (voltage)
25
1,100 V ÷ 42.94 V
Min modules (MPPT)
6
MPPT 6, start-up 5
Max circuit current
17.6A
1 string(s) × Isc × 1.25 vs 22 A
Array DC power
10.32kWp
12 × 1 × 2 MPPT = 24 modules
DC/AC ratio
1.03
healthy 0.9–1.5
Checks passed
6 / 6
all good
Design checks
| Check | Value | Result |
|---|---|---|
| Voc at the coldest temperature on record ≤ maximum DC voltage | 515 V ≤ 1,100 V | OK |
| Vmp with hot cells ≥ lower MPPT limit | 335 V ≥ 160 V | OK |
| Vmp at cold ≤ MPPT high | 440 V ≤ 1,000 V | OK |
| Voc on a hot morning ≥ start-up voltage | 446 V ≥ 180 V | OK |
| Isc × 1.25 ≤ inverter max Isc | 17.6 A ≤ 22 A | OK |
| Imp ≤ max input current | 13.6 A ≤ 16 A | OK |
String length options
| Modules | Voc cold (V) | Vmp hot (V) | Vmp cold (V) | kWp/string | Status |
|---|---|---|---|---|---|
| 4 | 172 | 112 | 147 | 1.72 | ✗ below MPPT |
| 5 | 215 | 140 | 183 | 2.15 | ✗ below MPPT |
| 6 | 258 | 168 | 220 | 2.58 | ✓ |
| 7 | 301 | 196 | 257 | 3.01 | ✓ |
| 8 | 344 | 224 | 293 | 3.44 | ✓ |
| 9 | 386 | 251 | 330 | 3.87 | ✓ |
| 10 | 429 | 279 | 367 | 4.3 | ✓ |
| 11 | 472 | 307 | 403 | 4.73 | ✓ |
| 12 ◀ | 515 | 335 | 440 | 5.16 | ✓ |
| 13 | 558 | 363 | 477 | 5.59 | ✓ |
| 14 | 601 | 391 | 513 | 6.02 | ✓ |
| 15 | 644 | 419 | 550 | 6.45 | ✓ |
| 16 | 687 | 447 | 587 | 6.88 | ✓ |
| 17 | 730 | 475 | 623 | 7.31 | ✓ |
| 18 | 773 | 503 | 660 | 7.74 | ✓ |
| 19 | 816 | 531 | 697 | 8.17 | ✓ |
| 20 | 859 | 559 | 733 | 8.6 | ✓ |
| 21 | 902 | 587 | 770 | 9.03 | ✓ |
| 22 | 945 | 615 | 807 | 9.46 | ✓ |
| 23 | 988 | 643 | 843 | 9.89 | ✓ |
| 24 | 1,031 | 671 | 880 | 10.32 | ✓ |
| 25 | 1,074 | 698 | 917 | 10.75 | ✓ |
| 26 | 1,117 | 726 | 953 | 11.18 | ✗ over max V |
| 27 | 1,159 | 754 | 990 | 11.61 | ✗ over max V |
- Cold-day Voc = Voc × [1 + β × (T_min − 25)], where β = -0.25 %/°C. No sunshine heating is assumed, so cells match the air temperature at dawn.
- Vmp drift uses the Pmax coefficient as a stand-in, since datasheets rarely give the Vmp one (the real value is usually 0.02–0.05 %/°C lower). Leave a few percent of headroom under the maximum DC voltage.
- Current rises with module tolerance, bifacial gain and irradiance beyond 1,000 W/m² from cloud-edge effects. An inverter limits what it draws, yet a module Isc higher than the stated input rating is a violation.