Expect to drill about 140 m (2 × 70 m) for a 8 kW ground-source heat pump in “Average soil / rock (λ ≈ 2 W/mK)”, assuming ~47 W/m. SCOP is ≈ 4.23, and running costs fall by 141 €/yr against an air-source unit. A yearly energy limit of ~100 kWh per metre, not peak power, fixes the length so the ground is not drained of heat over the years.
Total borehole length
140m
2 boreholes × 70 m · 47 W/m
Heat pump size
8kW
design heat loss 7 kW at -9 °C
Seasonal COP (SCOP)
4.23
air-source equivalent 3.79
Running cost
€1,216
Yearly electricity draw: 4,342 kWh
Saving vs air source
€141
Saving vs gas boiler
€825
gas 2,041 €/yr at 90% efficiency
Estimated installed cost
€21,818
ground loop 9,818 + unit 12,000
Heat drawn from the soil
14,026kWh/yr
100 kWh per m of borehole
Full-load hours
2,296h/yr
Annual heat delivered
18,368kWh
CO₂ per year
1.52t
vs 3.73 t with gas
Ground temperature
11.4°C
Berlin, Germany
Ground types and their VDI 4640 guide extraction rates
| Ground | Borehole W/m (1,800 h) | W/m (2,400 h) | Horizontal W/m² (1,800 h) | Borehole needed (m) | Loop area (m²) |
|---|---|---|---|---|---|
| Dry gravel / sand | 25 | 20 | 12 | 293 | 642 |
| Moist clay / loam | 45 | 35 | 28 | 166 | 265 |
| Gravel / sand saturated with water | 70 | 60 | 38 | 140 | 234 |
| Limestone (massive) | 62 | 52 | 30 | 140 | 244 |
| Sandstone | 72 | 60 | 30 | 140 | 244 |
| Granite / gneiss | 75 | 63 | 30 | 140 | 244 |
| Basalt | 52 | 45 | 30 | 140 | 244 |
| Average soil / rock (λ ≈ 2 W/mK) | 55 | 45 | 25 | 140 | 293 |
- The extraction rates come from VDI 4640 guide values, which suit small installations (< 30 kW) with no groundwater movement. For a final design, rely on a thermal response test plus an EED/GLHEPro-style simulation, or on the MCS MIS 3005 tables.
- The borehole length you see is whichever is greater: the figure from the peak-power rule (W/m) or the one from a yearly energy cap of 100 kWh/m (60 kWh/m² for horizontal loops). Keep boreholes at least 6 m apart as a rule. A horizontal loop wants free land of about 1.5–2× the heated floor area.
- Climate used: Berlin, Germany. During the heating season the brine circulates roughly 4–8 K colder than the undisturbed ground.