Results

Net efficiency of 55% (LHV) is the same as 6,874 Btu/kWh on an HHV basis, or 6,545 kJ/kWh on LHV. For each MWh you feed in 6.55 GJ of fuel, roughly 190 m³ (Natural gas); that costs 52.4 € and releases 0.367 t CO₂.
Heat rate (HHV)
6,874Btu/kWh
6,204 Btu/kWh on an LHV basis
Net efficiency (LHV)
55%
Net efficiency (HHV)
49.6%
Heat rate (LHV)
6,545kJ/kWh
1,563 kcal/kWh
Fuel energy per MWh (LHV)
6.55GJ/MWh
6.87 MMBtu/MWh HHV
Fuel per MWh (Natural gas)
190m³
Fuel cost per MWh
52.4€/MWh
CO₂ per MWh
0.367t
367 g/kWh
Annual generation
1,927GWh
Annual fuel use
365.6million m³
12.61 PJ of fuel
Yearly cost of fuel and carbon
101million €
Annual CO₂
0.71Mt
Heat rate against efficiency (LHV)
Usual net efficiency for each technology (LHV)

Heat rate in every unit

UnitLHV basisHHV basis
Btu/kWh6,2046,874
kJ/kWh6,5457,252
kcal/kWh1,5631,732
GJ/MWh6.5457.252
MMBtu/MWh6.2046.874

Typical technologies

TechnologyEfficiency (LHV)Heat rate (kJ/kWh, LHV)Heat rate (Btu/kWh, LHV)
Old subcritical coal33%10,90910,340
Supercritical coal39%9,2318,749
Ultra-supercritical coal44%8,1827,755
Lignite (modern)40%9,0008,530
Gas engine / recip44%8,1827,755
Aeroderivative OCGT40%9,0008,530
Heavy-duty OCGT37%9,7309,222
CCGT (F-class)57%6,3165,986
CCGT (H/J-class)62%5,8065,503
Oil steam plant36%10,0009,478
Diesel genset38%9,4748,979
Biomass steam30%12,00011,374
Nuclear LWR33%10,90910,340
  • To get the heat rate, divide 3,600 kJ/kWh (or 3,412 Btu/kWh) by the efficiency. Switching between HHV and LHV uses standard ratios per fuel: gas 1.108, bituminous coal 1.045, lignite 1.09, oil 1.06.
  • Default values from IPCC 2006 supply the calorific values and CO₂ factors. Your own fuel analysis will give other figures, most of all for coal and lignite.

Free calculator by Energy.com.info