Net efficiency of 55% (LHV) is the same as 6,874 Btu/kWh on an HHV basis, or 6,545 kJ/kWh on LHV. For each MWh you feed in 6.55 GJ of fuel, roughly 190 m³ (Natural gas); that costs 52.4 € and releases 0.367 t CO₂.
Heat rate (HHV)
6,874Btu/kWh
6,204 Btu/kWh on an LHV basis
Net efficiency (LHV)
55%
Net efficiency (HHV)
49.6%
Heat rate (LHV)
6,545kJ/kWh
1,563 kcal/kWh
Fuel energy per MWh (LHV)
6.55GJ/MWh
6.87 MMBtu/MWh HHV
Fuel per MWh (Natural gas)
190m³
Fuel cost per MWh
52.4€/MWh
CO₂ per MWh
0.367t
367 g/kWh
Annual generation
1,927GWh
Annual fuel use
365.6million m³
12.61 PJ of fuel
Yearly cost of fuel and carbon
101million €
Annual CO₂
0.71Mt
Heat rate in every unit
| Unit | LHV basis | HHV basis |
|---|---|---|
| Btu/kWh | 6,204 | 6,874 |
| kJ/kWh | 6,545 | 7,252 |
| kcal/kWh | 1,563 | 1,732 |
| GJ/MWh | 6.545 | 7.252 |
| MMBtu/MWh | 6.204 | 6.874 |
Typical technologies
| Technology | Efficiency (LHV) | Heat rate (kJ/kWh, LHV) | Heat rate (Btu/kWh, LHV) |
|---|---|---|---|
| Old subcritical coal | 33% | 10,909 | 10,340 |
| Supercritical coal | 39% | 9,231 | 8,749 |
| Ultra-supercritical coal | 44% | 8,182 | 7,755 |
| Lignite (modern) | 40% | 9,000 | 8,530 |
| Gas engine / recip | 44% | 8,182 | 7,755 |
| Aeroderivative OCGT | 40% | 9,000 | 8,530 |
| Heavy-duty OCGT | 37% | 9,730 | 9,222 |
| CCGT (F-class) | 57% | 6,316 | 5,986 |
| CCGT (H/J-class) | 62% | 5,806 | 5,503 |
| Oil steam plant | 36% | 10,000 | 9,478 |
| Diesel genset | 38% | 9,474 | 8,979 |
| Biomass steam | 30% | 12,000 | 11,374 |
| Nuclear LWR | 33% | 10,909 | 10,340 |
- To get the heat rate, divide 3,600 kJ/kWh (or 3,412 Btu/kWh) by the efficiency. Switching between HHV and LHV uses standard ratios per fuel: gas 1.108, bituminous coal 1.045, lignite 1.09, oil 1.06.
- Default values from IPCC 2006 supply the calorific values and CO₂ factors. Your own fuel analysis will give other figures, most of all for coal and lignite.