With the upgrades, fabric heat loss falls 49% and about 7,220 kWh of fuel (722 €) is saved each year, so they repay themselves in ~19.2 years. Walls gives the best value, with a 6.3-year payback.
Money saved per year
€722
7,220 kWh of fuel per year
Payback (all measures)
19 yr 2 mo
cost 13,850 €
Heat loss before
13,192kWh/yr
fabric only, 298 W/K
Heat loss after
6,693kWh/yr
125 W/K
Drop in fabric heat loss
49.3%
CO₂ saved per year
1.32t
30-year savings
€34,350
with 3%/yr price growth
Design heat loss cut
4.14kW
with 21 °C inside and −3 °C outside, which lets you fit a smaller boiler or heat pump
Heating degree days
1,844K·d (base 15.5 °C)
London, UK
Savings per measure
| Element | Area (m²) | U before → after | kWh fuel saved | Saved (€/yr) | Cost (€) | Payback |
|---|---|---|---|---|---|---|
| Walls | 110 | 1.5 → 0.55 | 4,369 | 437 | 2,750 | 6.3 yrs |
| Roof / loft | 60 | 0.7 → 0.15 | 1,380 | 138 | 1,200 | 8.7 yrs |
| Windows & doors | 22 | 2.8 → 1.2 | 1,472 | 147 | 9,900 | 67.3 yrs |
| Ground floor | 60 | 0.7 → 0.7 | 0 | 0 | 0 | — |
- Degree days: London, UK (approximate 1991–2020 normals) with base 15.5 °C.
- Ground-floor losses are scaled by 0.7, since the soil stays warmer than outside air in winter. Ventilation and air leakage losses are left out of this calculation.
- All savings are reduced by a 15% performance gap, which stands for thermal bridges, workmanship and the warmer indoor temperatures people choose after insulating.