How the estimate works
Every element of a building, whether wall, roof, window, door or floor, loses heat at a rate set by area times U-value. How much is lost across a season depends on the heating degree days of the climate. This is the textbook approach, shared with EN ISO 13790/52016 and national energy-rating software, and the calculator applies it element by element, before and after the upgrade.
- Fill in area and U-value before and after for walls, roof, windows and ground floor. Typical values are offered as hints.
- Heating degree days are taken from 1991–2020 normals for 16 preset cities, from NASA satellite climatology elsewhere, or from a number you enter.
- Yearly heat loss is computed for each element in both states. A performance gap reduces the difference, your heating system’s efficiency (or the heat pump’s SCOP) converts the saved heat into fuel saved, and the fuel is priced.
- Enter your installed cost per m² and every measure gets a payback, which shows the order in which to do the work.
Formula
Soil under a house is warmer than winter air, so ground floors carry a factor of 0.7. Ventilation and air leakage are excluded, as insulation leaves them unchanged (draught-proofing excepted).
Worked example: London semi-detached
The preset house is a typical inter-war or post-war London home (≈ 1,840 heating degree days to 15.5 °C). Heating is a 90% efficient gas boiler, gas costs 0.10 €/kWh, and three measures are priced.
| Measure | Area | U-value | Saves | Cost | Payback |
|---|---|---|---|---|---|
| Cavity wall fill | 110 m² | 1.50 → 0.55 | 4,369 kWh, 437 €/yr | 2,750 € | 6.3 years |
| Loft top-up to 270 mm | 60 m² | 0.70 → 0.15 | 1,380 kWh, 138 €/yr | 1,200 € | 8.7 years |
| Old double glazing swapped for new double | 22 m² | 2.80 → 1.20 | 1,472 kWh, 147 €/yr | 9,900 € | 67 years |
| Whole package | Result |
|---|---|
| Fabric loss | about 13,190 kWh → 6,690 kWh a year (298 W/K → 125 W/K), a 49% reduction |
| Saving after the 15% performance gap | about 7,220 kWh of gas and 722 € a year, plus 1.3 t of CO₂ |
| Cost and payback | 13,850 €, about 19 years |
| Walls and loft only | roughly 7 years |
| Windows only | 67 years |
| 30-year value, gas up 3% a year | about 34,000 € |
| Design heat loss | down by about 4.1 kW |
The lower design heat loss means the heat pump can be visibly smaller.
Reading the results
| Result | What to take from it |
|---|---|
| Savings per measure | Rank jobs by payback and do the quickest first. |
| Reduction in fabric loss | 40–60% is typical of a solid retrofit; 70–80% signals a deep one. |
| Design heat loss cut | Feeds directly into boiler or heat pump sizing. |
| Monthly fuel saving | Most of the gain arrives between November and March. |
| 30-year savings | Insulation often lasts 30–50 years with no upkeep, so lifetime value stays high even when payback is long. |
U-values to expect
| Element | Before | After (good practice) |
|---|---|---|
| Solid brick wall (225 mm) | 2.0–2.1 | 0.25–0.30 with 100 mm EWI |
| Unfilled cavity wall | 1.4–1.6 | 0.45–0.55 once filled |
| Timber frame (1970s) | 0.5–0.6 | 0.18–0.25 |
| Loft, no insulation | 2.0–2.5 | 0.12–0.16 at 270–300 mm |
| Loft with 50 mm | 0.6–0.7 | 0.12–0.16 |
| Single glazing | 4.8–5.8 | double 1.2–1.4, triple 0.7–0.9 |
| Old double glazing (pre-2000) | 2.8–3.1 | new double 1.2–1.4, triple 0.7–0.9 |
| Suspended timber floor | 0.7–1.0 | 0.20–0.25 |
Making the work count
- Start cheap. The quickest returns come from loft, cavity and draught-proofing.
- Ventilate. A sealed-up house needs trickle vents or mechanical ventilation against damp air.
- Combine jobs. If scaffolding is going up anyway for re-rendering or a new roof, external wall insulation costs least.
- Treat thermal bridges. Unprotected window reveals and junctions can eat 10–20% of a wall upgrade’s benefit.
- Then resize the heating. The heat pump calculator sizes the unit you need now; the heating cost comparison weighs one fuel against another.
What is not modelled
Calculations are steady-state and degree-day based. Solar gain through glazing, thermal mass and airtightness changes are all left out; including solar gain would trim the value of glazing upgrades on south façades and raise it on north ones. Degree days derived from monthly climate data land within about ±10% of station records. The “before” U-values drive every result, so commission a survey if they are uncertain. If your country offers grants or reduced VAT on insulation, enter the amount as a lump sum under advanced settings.
Method & assumptions
For each building element, annual fabric heat loss is Q = A × U × HDD × 24 / 1000 in kWh, with HDD the heating degree days to the base temperature. An upgrade is worth (Ubefore − Uafter) × A × HDD × 24/1000 × (1 − performance gap). To turn heat into fuel, divide by the efficiency of the heating system (or SCOP). The undiscounted payback is the installed cost divided by money saved per year.
Frequently asked questions
How much can insulation save on heating bills?
What does U-value mean?
Why do heating degree days matter?
What insulation upgrade repays itself soonest?
Why do measured savings fall short of the calculation?
Does insulation help when I fit a heat pump?
Sources & references
- ISO 6946:2017 — Building components and building elements: thermal resistance and thermal transmittance, calculation methods
- CIBSE TM41 (2006) — Degree-days: theory and application
- Degree Days.net — degree-day data and methodology
- UK DESNZ — Greenhouse gas reporting: conversion factors 2024
- Energy Saving Trust — Home insulation
Embed this calculator