Heating & gas calculator

How much will better insulation save? U-value upgrades, energy and payback

Give the area and U-value of the walls, roof, windows and floor as they are now and after insulating. The tool applies the heating degree days of your climate and reports heat loss avoided, energy and money saved, CO₂ and the payback of each measure.

Editable share link Branded PDF report Free · no sign-up

Results

With the upgrades, fabric heat loss falls 49% and about 7,220 kWh of fuel (722 €) is saved each year, so they repay themselves in ~19.2 years. Walls gives the best value, with a 6.3-year payback.
Money saved per year
€722
7,220 kWh of fuel per year
Payback (all measures)
19 yr 2 mo
cost 13,850 €
Heat loss before
13,192kWh/yr
fabric only, 298 W/K
Heat loss after
6,693kWh/yr
125 W/K
Drop in fabric heat loss
49.3%
CO₂ saved per year
1.32t
30-year savings
€34,350
with 3%/yr price growth
Design heat loss cut
4.14kW
with 21 °C inside and −3 °C outside, which lets you fit a smaller boiler or heat pump
Heating degree days
1,844K·d (base 15.5 °C)
London, UK
Heat lost each year, by element
Monthly fuel saving

Savings per measure

ElementArea (m²)U before → afterkWh fuel savedSaved (€/yr)Cost (€)Payback
Walls1101.5 → 0.554,3694372,7506.3 yrs
Roof / loft600.7 → 0.151,3801381,2008.7 yrs
Windows & doors222.8 → 1.21,4721479,90067.3 yrs
Ground floor600.7 → 0.7000—
  • Degree days: London, UK (approximate 1991–2020 normals) with base 15.5 °C.
  • Ground-floor losses are scaled by 0.7, since the soil stays warmer than outside air in winter. Ventilation and air leakage losses are left out of this calculation.
  • All savings are reduced by a 15% performance gap, which stands for thermal bridges, workmanship and the warmer indoor temperatures people choose after insulating.

How the estimate works

Every element of a building, whether wall, roof, window, door or floor, loses heat at a rate set by area times U-value. How much is lost across a season depends on the heating degree days of the climate. This is the textbook approach, shared with EN ISO 13790/52016 and national energy-rating software, and the calculator applies it element by element, before and after the upgrade.

  1. Fill in area and U-value before and after for walls, roof, windows and ground floor. Typical values are offered as hints.
  2. Heating degree days are taken from 1991–2020 normals for 16 preset cities, from NASA satellite climatology elsewhere, or from a number you enter.
  3. Yearly heat loss is computed for each element in both states. A performance gap reduces the difference, your heating system’s efficiency (or the heat pump’s SCOP) converts the saved heat into fuel saved, and the fuel is priced.
  4. Enter your installed cost per m² and every measure gets a payback, which shows the order in which to do the work.

Formula

Heat loss coefficient H = A × U (W/K) Annual heat loss Q = H × HDD × 24 / 1000 (kWh/yr) Fuel saved = (U_before − U_after) × A × HDD × 24/1000 × (1 − gap) / η_heating Money saved = fuel saved × price Payback = installed cost / money saved Design heat-loss reduction = ΔH × (21 °C − T_design)

Soil under a house is warmer than winter air, so ground floors carry a factor of 0.7. Ventilation and air leakage are excluded, as insulation leaves them unchanged (draught-proofing excepted).

Worked example: London semi-detached

The preset house is a typical inter-war or post-war London home (≈ 1,840 heating degree days to 15.5 °C). Heating is a 90% efficient gas boiler, gas costs 0.10 €/kWh, and three measures are priced.

Measure Area U-value Saves Cost Payback
Cavity wall fill 110 m² 1.50 → 0.55 4,369 kWh, 437 €/yr 2,750 € 6.3 years
Loft top-up to 270 mm 60 m² 0.70 → 0.15 1,380 kWh, 138 €/yr 1,200 € 8.7 years
Old double glazing swapped for new double 22 m² 2.80 → 1.20 1,472 kWh, 147 €/yr 9,900 € 67 years
Whole package Result
Fabric loss about 13,190 kWh → 6,690 kWh a year (298 W/K → 125 W/K), a 49% reduction
Saving after the 15% performance gap about 7,220 kWh of gas and 722 € a year, plus 1.3 t of CO₂
Cost and payback 13,850 €, about 19 years
Walls and loft only roughly 7 years
Windows only 67 years
30-year value, gas up 3% a year about 34,000 €
Design heat loss down by about 4.1 kW

The lower design heat loss means the heat pump can be visibly smaller.

Reading the results

Result What to take from it
Savings per measure Rank jobs by payback and do the quickest first.
Reduction in fabric loss 40–60% is typical of a solid retrofit; 70–80% signals a deep one.
Design heat loss cut Feeds directly into boiler or heat pump sizing.
Monthly fuel saving Most of the gain arrives between November and March.
30-year savings Insulation often lasts 30–50 years with no upkeep, so lifetime value stays high even when payback is long.

U-values to expect

Element Before After (good practice)
Solid brick wall (225 mm) 2.0–2.1 0.25–0.30 with 100 mm EWI
Unfilled cavity wall 1.4–1.6 0.45–0.55 once filled
Timber frame (1970s) 0.5–0.6 0.18–0.25
Loft, no insulation 2.0–2.5 0.12–0.16 at 270–300 mm
Loft with 50 mm 0.6–0.7 0.12–0.16
Single glazing 4.8–5.8 double 1.2–1.4, triple 0.7–0.9
Old double glazing (pre-2000) 2.8–3.1 new double 1.2–1.4, triple 0.7–0.9
Suspended timber floor 0.7–1.0 0.20–0.25

Making the work count

  • Start cheap. The quickest returns come from loft, cavity and draught-proofing.
  • Ventilate. A sealed-up house needs trickle vents or mechanical ventilation against damp air.
  • Combine jobs. If scaffolding is going up anyway for re-rendering or a new roof, external wall insulation costs least.
  • Treat thermal bridges. Unprotected window reveals and junctions can eat 10–20% of a wall upgrade’s benefit.
  • Then resize the heating. The heat pump calculator sizes the unit you need now; the heating cost comparison weighs one fuel against another.

What is not modelled

Calculations are steady-state and degree-day based. Solar gain through glazing, thermal mass and airtightness changes are all left out; including solar gain would trim the value of glazing upgrades on south façades and raise it on north ones. Degree days derived from monthly climate data land within about ±10% of station records. The “before” U-values drive every result, so commission a survey if they are uncertain. If your country offers grants or reduced VAT on insulation, enter the amount as a lump sum under advanced settings.

Method & assumptions

For each building element, annual fabric heat loss is Q = A × U × HDD × 24 / 1000 in kWh, with HDD the heating degree days to the base temperature. An upgrade is worth (Ubefore − Uafter) × A × HDD × 24/1000 × (1 − performance gap). To turn heat into fuel, divide by the efficiency of the heating system (or SCOP). The undiscounted payback is the installed cost divided by money saved per year.

Frequently asked questions

How much can insulation save on heating bills?
Climate, treated area and the size of the U-value gain decide it. For a gas-heated semi-detached in the UK or Germany, ballpark yearly savings are 250–450 for cavity wall fill, 400–700 for external insulation on solid brick, 100–200 for a loft top-up (50 mm to 270 mm) and 100–200 for new glazing over old double. Cavity and loft jobs repay in 2–5 years; windows take over 30.
What does U-value mean?
Lower is better. A U-value (W/m²K) gives the heat passing through 1 m² of construction per degree of indoor-outdoor temperature difference. Typical values are about 2.0 for uninsulated solid brick, about 0.5 for filled cavity, 0.15–0.25 for a new-build wall, 4.8–5.8 for single glazing and 0.7–0.9 for modern triple.
Why do heating degree days matter?
A wall loses heat in step with this figure. Count, day by day, the degrees by which mean outdoor temperature falls below a base (commonly 15.5 °C, allowing for internal gains), and add them up over the year. London comes to about 1,800–2,000, Berlin 2,400–2,700 and Stockholm 3,200–3,600.
What insulation upgrade repays itself soonest?
Loft (attic) insulation and filling the cavity walls, with draught-proofing next. Each is cheap per m² and plugs a big leak. Solid-wall insulation (outside or inside) and new windows save a lot too, but they cost much more per m², so payback is slow.
Why do measured savings fall short of the calculation?
This is known as the 'performance gap'. Thermal bridges at junctions, imperfect workmanship and households turning the heating up once the house is warmer (comfort take-back) all play a part. In studies, measured savings often come out 10–50% under the engineering estimate. The calculator deducts an adjustable 15% by default.
Does insulation help when I fit a heat pump?
Yes, twice over. You use fewer kWh a year and the design heat loss shrinks too. That allows a smaller, cheaper heat pump, run at a lower flow temperature, which raises its efficiency.

Sources & references

  1. ISO 6946:2017 — Building components and building elements: thermal resistance and thermal transmittance, calculation methods
  2. CIBSE TM41 (2006) — Degree-days: theory and application
  3. Degree Days.net — degree-day data and methodology
  4. UK DESNZ — Greenhouse gas reporting: conversion factors 2024
  5. Energy Saving Trust — Home insulation

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.