Two Scope 2 totals result. Location-based: 1,650 t CO₂e, using Germany at 330 kg/MWh. Market-based: 1,500 t CO₂e, because renewable PPAs or certificates back 50% of the electricity, and the remaining 2,500 MWh takes the 600 kg/MWh residual mix.
Market-based Scope 2
1,500t CO₂e
Location-based Scope 2
1,650t CO₂e
grid factor 330 kg/MWh
Difference
150t CO₂e
Renewable share (market-based)
50%
Covered by PPA
1,000MWh
Covered by certificates
1,500MWh
At residual mix
2,500MWh
1,500 t CO₂e
Market-based intensity
300kg CO₂e/MWh
Own solar (outside Scope 2)
300MWh
99 t avoided compared with the grid average
Market-based calculation
| Source | MWh | Factor (kg CO₂e/MWh) | t CO₂e |
|---|---|---|---|
| Renewable PPA | 1,000 | 0 | 0 |
| Certificates | 1,500 | 0 | 0 |
| Supplier tariff | 0 | 250 | 0 |
| Residual mix | 2,500 | 600 | 1,500 |
| Purchased heat / steam | 0 | 250 | 0 |
- The grid factors on the list are lifecycle averages in g CO₂e/kWh (OWID/Ember). Official reports call for the factor your scheme prescribes (such as IEA, a national inventory or US eGRID), paired with residual mixes like AIB (Europe) or Green-e (US).
- To qualify, market instruments need to meet GHG Protocol Scope 2 quality criteria: same market, same vintage, retired for you. Scope 2 guidance is under revision at the GHG Protocol, so look up the current edition.