Carbon & climate calculator

Scope 2 CO₂ calculator using the location and market methods

Convert bought-in power, heat and steam into Scope 2 emissions the GHG Protocol way, twice over. One result uses the average intensity of your grid; the other counts certificates, PPAs, green tariffs, supplier-specific factors and residual mix.

Editable share link Branded PDF report Free · no sign-up

Results

Two Scope 2 totals result. Location-based: 1,650 t CO₂e, using Germany at 330 kg/MWh. Market-based: 1,500 t CO₂e, because renewable PPAs or certificates back 50% of the electricity, and the remaining 2,500 MWh takes the 600 kg/MWh residual mix.
Market-based Scope 2
1,500t CO₂e
Location-based Scope 2
1,650t CO₂e
grid factor 330 kg/MWh
Difference
150t CO₂e
Renewable share (market-based)
50%
Covered by PPA
1,000MWh
Covered by certificates
1,500MWh
At residual mix
2,500MWh
1,500 t CO₂e
Market-based intensity
300kg CO₂e/MWh
Own solar (outside Scope 2)
300MWh
99 t avoided compared with the grid average
Scope 2 by method (t CO₂e)
How the electricity is sourced (MWh)

Market-based calculation

SourceMWhFactor (kg CO₂e/MWh)t CO₂e
Renewable PPA1,00000
Certificates1,50000
Supplier tariff02500
Residual mix2,5006001,500
Purchased heat / steam02500
  • The grid factors on the list are lifecycle averages in g CO₂e/kWh (OWID/Ember). Official reports call for the factor your scheme prescribes (such as IEA, a national inventory or US eGRID), paired with residual mixes like AIB (Europe) or Green-e (US).
  • To qualify, market instruments need to meet GHG Protocol Scope 2 quality criteria: same market, same vintage, retired for you. Scope 2 guidance is under revision at the GHG Protocol, so look up the current edition.

One purchase, two reported numbers

Reporting companies must cover Scope 2, the emissions behind purchased electricity, heat, steam and cooling. Under the 2015 GHG Protocol Scope 2 Guidance the answer is two figures, not one. The location-based number uses the regional grid’s mean emission factor. The market-based number follows your own procurement: renewable PPAs, energy attribute certificates (RECs in North America, Guarantees of Origin in Europe, I-RECs elsewhere), green tariffs and supplier-specific factors.

Type in annual consumption and your contracts to get both. The tool caps instruments at total consumption and prices the rest at the residual mix, then lays out every line in a table ready for a report.

Formulas used

Location-based = Σ MWh_grid × average grid factor (+ purchased heat × heat factor)

Market-based = MWh_PPA × 0 + MWh_certificates × 0 + MWh_supplier × supplier factor + MWh_uncovered × residual mix factor (+ purchased heat × heat factor)

MWh_uncovered = consumption − (PPA + certificates + supplier-specific), not below zero

The order is PPA first, certificates second, supplier tariff third. It only affects the answer if the three exceed consumption, because then the extra cannot be claimed.

Walk-through with the presets

Take a German organisation with 5,000 MWh of annual purchases. Contracts: a 1,000 MWh renewable PPA and 1,500 MWh of Guarantees of Origin. The residual-mix factor is 600 kg CO₂e/MWh. Its own rooftop solar supplies a further 300 MWh.

  • Location-based: 5,000 × 330 kg/MWh, the most recent German average in the dataset, comes to 1,650 t CO₂e.
  • Market-based: 2,500 MWh (PPA plus certificates) count as zero; The uncovered 2,500 MWh at 600 kg/MWh adds up to 1,500 t CO₂e. That is a 50% renewable share and an intensity of 300 kg/MWh.
  • The rooftop solar is not Scope 2. Those 300 MWh never bought from the grid represent roughly 99 t avoided.

Only 150 t separate the two totals although half the supply is covered. The residual mix is to blame. It runs well above the average, because other buyers have already taken the clean power. With certificates for all 5,000 MWh (second preset) market-based Scope 2 reaches zero and location-based remains 1,650 t.

Sources for each factor

Factor Where to find it
Grid average, location-based IEA emission factors, a national inventory, the US eGRID subregion, or the averages built into this tool
Residual mix, Europe AIB European Residual Mixes (yearly publication)
Residual mix, US Green-e Residual Mix
Supplier-specific Your supplier’s fuel-mix disclosure for the tariff you are on
Bought heat or steam Your district heating or steam provider

Built-in grid factors are lifecycle averages from Our World in Data / Ember, which suit estimates. Official disclosures often ask for combustion-only factors from a named source. Type that value into the custom factor box.

Using the outputs

  • Market-based: the one most firms use for targets and RE100 claims, as long as the instruments satisfy the quality criteria.
  • Location-based: the physical effect on the grid. Bringing it down means consuming less or moving consumption to cleaner times or places.
  • Gap between them: the reported value of your contracts.
  • Market-based intensity: handy for ranking sites or suppliers.

Scope of the model

It handles one site for one year. A company present in several countries has to run every location separately, using local factors and instruments. Neither hourly matching (“24/7 carbon-free energy”) nor the GHG Protocol’s planned Scope 2 changes are reflected. Grid transmission and distribution losses are usually Scope 3 (category 3) items. The electricity CO₂ calculator converts kWh to CO₂ by country in seconds, and the grid emission factor calculator builds a factor from a generation mix.

Method & assumptions

The location-based figure is grid MWh × the average grid emission factor, plus purchased heat × its factor. For the market-based figure, add up each contractual instrument's covered MWh × its factor (renewable PPAs and certificates are 0; a supplier-specific factor is used as stated), then add the uncovered MWh × the residual mix factor, plus heat. No instrument can cover more than total consumption. Power you generate yourself is never purchased, so Scope 2 does not include it.

Frequently asked questions

What falls under Scope 2?
Scope 2 is a company's indirect climate impact from energy it buys: electricity, steam, heat and cooling. The gases leave a power or heating plant elsewhere, but the GHG Protocol Corporate Standard books them to whoever uses the energy.
Location-based or market-based Scope 2: what separates them?
One looks at geography, the other at contracts. Location-based takes your kWh and applies the typical factor for the regional grid. Market-based mirrors your buying decisions: certificates, PPAs, green tariffs and supplier factors. Consumption those do not cover is valued at the residual mix. The GHG Protocol asks for both figures (dual reporting).
What is the way to work out location-based Scope 2?
Take the electricity used at each site, multiply by the grid's average emission factor and add the sites together. Sample: 5,000 MWh used where the grid averages 330 kg CO₂e/MWh results in 1,650 t CO₂e. Heat or steam you buy is added at the supplier's factor.
Define the residual mix factor.
Strip every certificate and other claim out of the grid mix and what is left carries the residual mix factor. Since other buyers already took the cleaner MWh, this factor normally sits above the grid average. AIB issues European residual mixes every year; in the US the source is Green-e.
Can buying RECs or Guarantees of Origin reduce Scope 2?
They can lower the market-based figure, but only if they pass the GHG Protocol quality tests. They must come from the market where you consume, relate to a similar period, and be retired for you. Location-based Scope 2 does not move. Experts disagree about whether unbundled certificates build new renewable capacity, and that debate is one driver of the GHG Protocol's Scope 2 revision.
Is power from solar panels I own part of Scope 2?
No. Nothing was bought, so nothing is reported under Scope 2, and solar burns no fuel, so Scope 1 is clear as well. It just shrinks your grid purchases. If a third party owns the rooftop system and sells you its output under a PPA, that power is Scope 2, at a market-based factor of zero when the certificates are included.

Sources & references

  1. GHG Protocol — Scope 2 Guidance (2015, amendment to the Corporate Standard)
  2. Association of Issuing Bodies (AIB) — European Residual Mixes
  3. US EPA — eGRID (Emissions & Generation Resource Integrated Database)
  4. Our World in Data / Ember — Carbon intensity of electricity generation

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.