One purchase, two reported numbers
Reporting companies must cover Scope 2, the emissions behind purchased electricity, heat, steam and cooling. Under the 2015 GHG Protocol Scope 2 Guidance the answer is two figures, not one. The location-based number uses the regional grid’s mean emission factor. The market-based number follows your own procurement: renewable PPAs, energy attribute certificates (RECs in North America, Guarantees of Origin in Europe, I-RECs elsewhere), green tariffs and supplier-specific factors.
Type in annual consumption and your contracts to get both. The tool caps instruments at total consumption and prices the rest at the residual mix, then lays out every line in a table ready for a report.
Formulas used
Market-based = MWh_PPA × 0 + MWh_certificates × 0 + MWh_supplier × supplier factor + MWh_uncovered × residual mix factor (+ purchased heat × heat factor)
MWh_uncovered = consumption − (PPA + certificates + supplier-specific), not below zero
The order is PPA first, certificates second, supplier tariff third. It only affects the answer if the three exceed consumption, because then the extra cannot be claimed.
Walk-through with the presets
Take a German organisation with 5,000 MWh of annual purchases. Contracts: a 1,000 MWh renewable PPA and 1,500 MWh of Guarantees of Origin. The residual-mix factor is 600 kg CO₂e/MWh. Its own rooftop solar supplies a further 300 MWh.
- Location-based: 5,000 × 330 kg/MWh, the most recent German average in the dataset, comes to 1,650 t CO₂e.
- Market-based: 2,500 MWh (PPA plus certificates) count as zero; The uncovered 2,500 MWh at 600 kg/MWh adds up to 1,500 t CO₂e. That is a 50% renewable share and an intensity of 300 kg/MWh.
- The rooftop solar is not Scope 2. Those 300 MWh never bought from the grid represent roughly 99 t avoided.
Only 150 t separate the two totals although half the supply is covered. The residual mix is to blame. It runs well above the average, because other buyers have already taken the clean power. With certificates for all 5,000 MWh (second preset) market-based Scope 2 reaches zero and location-based remains 1,650 t.
Sources for each factor
| Factor | Where to find it |
|---|---|
| Grid average, location-based | IEA emission factors, a national inventory, the US eGRID subregion, or the averages built into this tool |
| Residual mix, Europe | AIB European Residual Mixes (yearly publication) |
| Residual mix, US | Green-e Residual Mix |
| Supplier-specific | Your supplier’s fuel-mix disclosure for the tariff you are on |
| Bought heat or steam | Your district heating or steam provider |
Built-in grid factors are lifecycle averages from Our World in Data / Ember, which suit estimates. Official disclosures often ask for combustion-only factors from a named source. Type that value into the custom factor box.
Using the outputs
- Market-based: the one most firms use for targets and RE100 claims, as long as the instruments satisfy the quality criteria.
- Location-based: the physical effect on the grid. Bringing it down means consuming less or moving consumption to cleaner times or places.
- Gap between them: the reported value of your contracts.
- Market-based intensity: handy for ranking sites or suppliers.
Scope of the model
It handles one site for one year. A company present in several countries has to run every location separately, using local factors and instruments. Neither hourly matching (“24/7 carbon-free energy”) nor the GHG Protocol’s planned Scope 2 changes are reflected. Grid transmission and distribution losses are usually Scope 3 (category 3) items. The electricity CO₂ calculator converts kWh to CO₂ by country in seconds, and the grid emission factor calculator builds a factor from a generation mix.
Method & assumptions
The location-based figure is grid MWh × the average grid emission factor, plus purchased heat × its factor. For the market-based figure, add up each contractual instrument's covered MWh × its factor (renewable PPAs and certificates are 0; a supplier-specific factor is used as stated), then add the uncovered MWh × the residual mix factor, plus heat. No instrument can cover more than total consumption. Power you generate yourself is never purchased, so Scope 2 does not include it.
Frequently asked questions
What falls under Scope 2?
Location-based or market-based Scope 2: what separates them?
What is the way to work out location-based Scope 2?
Define the residual mix factor.
Can buying RECs or Guarantees of Origin reduce Scope 2?
Is power from solar panels I own part of Scope 2?
Sources & references
Embed this calculator
Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.