With 4 m² of Flat-plate, selective absorber collectors, solar covers 61% of the yearly 3,411 kWh hot-water demand. The share is 91% in the sunniest month and 23% in the dimmest. Replacing your current water heater (Electric immersion heater) saves roughly 507 €/yr, and the outlay is back in 6.9 years.
Annual solar fraction
61%
2,097 kWh of 3,411 kWh
Solar heat delivered
2,097kWh/yr
524 kWh per m² of collector
Hot-water heat demand
3,411kWh/yr
includes 631 kWh of tank standby loss
Backup energy still required
1,314kWh/yr
Electric immersion heater, efficiency/COP 1
Annual saving
€507
after 68 kWh of pump electricity
Payback
6 yr 11 mo
IRR 14.4% · NPV 3,663 €
CO₂ avoided
0.81t/yr
16.2 t over 20 years
Storage for each m² of collector
50L/m²
50–75 L/m² is the sweet spot
Months at ~100% solar
2
Jul, Aug: plan for stagnation
Daily hot water
200L at 45 °C
1 tank volumes per day
Monthly f-chart results
| Month | Sunshine on the collector (kWh/m²/day) | Mains °C | Load (kWh) | Solar fraction | Solar (kWh) |
|---|---|---|---|---|---|
| Jan | 2.37 | 6.4 | 332 | 28% | 94 |
| Feb | 3.34 | 6.6 | 299 | 46% | 137 |
| Mar | 4.3 | 8.4 | 318 | 62% | 198 |
| Apr | 5.08 | 10.8 | 290 | 75% | 219 |
| May | 5.42 | 13.4 | 281 | 83% | 233 |
| Jun | 5.51 | 15.8 | 256 | 87% | 221 |
| Jul | 5.77 | 17.4 | 253 | 91% | 230 |
| Aug | 5.81 | 18 | 248 | 91% | 227 |
| Sep | 5.02 | 16.7 | 249 | 80% | 199 |
| Oct | 3.97 | 13.9 | 278 | 61% | 171 |
| Nov | 2.5 | 11 | 289 | 34% | 97 |
| Dec | 2.04 | 8.2 | 319 | 23% | 72 |
Sizing options (tank ≥ 50 L/m²)
| Collector | Tank (L) | Solar fraction | kWh/yr | kWh per m² |
|---|---|---|---|---|
| 1 m² | 200 | 23% | 785 | 785 |
| 2 m² | 200 | 40% | 1,365 | 683 |
| 3 m² | 200 | 53% | 1,792 | 597 |
| 4 m² ◀ | 200 | 61% | 2,097 | 524 |
| 5 m² | 250 | 68% | 2,312 | 462 |
| 6 m² | 300 | 72% | 2,451 | 408 |
| 8 m² | 400 | 77% | 2,618 | 327 |
| 10 m² | 500 | 80% | 2,731 | 273 |
| 12 m² | 600 | 82% | 2,813 | 234 |
- Climate inputs are long-term monthly NASA POWER irradiance and temperatures for 44.43, 26.1 (default-site values embedded for pre-rendering), converted to a 45° tilt at 180° azimuth (Hay–Davies). Mains-water temperature follows a smoothed air temperature trailing by one month.
- Calculation uses the monthly f-chart approach for liquid systems, with adjustments for tank size and hot-water temperature. The collector has F_R(τα) = 0.693 and F_R·U_L = 3.92 W/m²K.
- Flat-plate collectors were the f-chart's original target. Applied to evacuated tubes it still gives a decent estimate, normally within ±5 percentage points.