Results

With 4 m² of Flat-plate, selective absorber collectors, solar covers 61% of the yearly 3,411 kWh hot-water demand. The share is 91% in the sunniest month and 23% in the dimmest. Replacing your current water heater (Electric immersion heater) saves roughly 507 €/yr, and the outlay is back in 6.9 years.
Annual solar fraction
61%
2,097 kWh of 3,411 kWh
Solar heat delivered
2,097kWh/yr
524 kWh per m² of collector
Hot-water heat demand
3,411kWh/yr
includes 631 kWh of tank standby loss
Backup energy still required
1,314kWh/yr
Electric immersion heater, efficiency/COP 1
Annual saving
€507
after 68 kWh of pump electricity
Payback
6 yr 11 mo
IRR 14.4% · NPV 3,663 €
CO₂ avoided
0.81t/yr
16.2 t over 20 years
Storage for each m² of collector
50L/m²
50–75 L/m² is the sweet spot
Months at ~100% solar
2
Jul, Aug: plan for stagnation
Daily hot water
200L at 45 °C
1 tank volumes per day
Hot-water heat by month: solar against backup
Solar fraction as collector area grows

Monthly f-chart results

MonthSunshine on the collector (kWh/m²/day)Mains °CLoad (kWh)Solar fractionSolar (kWh)
Jan2.376.433228%94
Feb3.346.629946%137
Mar4.38.431862%198
Apr5.0810.829075%219
May5.4213.428183%233
Jun5.5115.825687%221
Jul5.7717.425391%230
Aug5.811824891%227
Sep5.0216.724980%199
Oct3.9713.927861%171
Nov2.51128934%97
Dec2.048.231923%72

Sizing options (tank ≥ 50 L/m²)

CollectorTank (L)Solar fractionkWh/yrkWh per m²
1 m²20023%785785
2 m²20040%1,365683
3 m²20053%1,792597
4 m² ◀20061%2,097524
5 m²25068%2,312462
6 m²30072%2,451408
8 m²40077%2,618327
10 m²50080%2,731273
12 m²60082%2,813234
  • Climate inputs are long-term monthly NASA POWER irradiance and temperatures for 44.43, 26.1 (default-site values embedded for pre-rendering), converted to a 45° tilt at 180° azimuth (Hay–Davies). Mains-water temperature follows a smoothed air temperature trailing by one month.
  • Calculation uses the monthly f-chart approach for liquid systems, with adjustments for tank size and hot-water temperature. The collector has F_R(τα) = 0.693 and F_R·U_L = 3.92 W/m²K.
  • Flat-plate collectors were the f-chart's original target. Applied to evacuated tubes it still gives a decent estimate, normally within ±5 percentage points.

Free calculator by Energy.com.info