Solar calculator

Size a solar water heater: collector area, tank, solar fraction and savings

Engineers use the f-chart method to size solar hot-water systems, and this tool applies it with NASA satellite climate data for your site. It reports the monthly solar fraction, savings against electric, gas or heat pump water heating, and payback.

Editable share link Branded PDF report Free · no sign-up

Results

With 4 m² of Flat-plate, selective absorber collectors, solar covers 61% of the yearly 3,411 kWh hot-water demand. The share is 91% in the sunniest month and 23% in the dimmest. Replacing your current water heater (Electric immersion heater) saves roughly 507 €/yr, and the outlay is back in 6.9 years.
Annual solar fraction
61%
2,097 kWh of 3,411 kWh
Solar heat delivered
2,097kWh/yr
524 kWh per m² of collector
Hot-water heat demand
3,411kWh/yr
includes 631 kWh of tank standby loss
Backup energy still required
1,314kWh/yr
Electric immersion heater, efficiency/COP 1
Annual saving
€507
after 68 kWh of pump electricity
Payback
6 yr 11 mo
IRR 14.4% · NPV 3,663 €
CO₂ avoided
0.81t/yr
16.2 t over 20 years
Storage for each m² of collector
50L/m²
50–75 L/m² is the sweet spot
Months at ~100% solar
2
Jul, Aug: plan for stagnation
Daily hot water
200L at 45 °C
1 tank volumes per day
Hot-water heat by month: solar against backup
Solar fraction as collector area grows

Monthly f-chart results

MonthSunshine on the collector (kWh/m²/day)Mains °CLoad (kWh)Solar fractionSolar (kWh)
Jan2.376.433228%94
Feb3.346.629946%137
Mar4.38.431862%198
Apr5.0810.829075%219
May5.4213.428183%233
Jun5.5115.825687%221
Jul5.7717.425391%230
Aug5.811824891%227
Sep5.0216.724980%199
Oct3.9713.927861%171
Nov2.51128934%97
Dec2.048.231923%72

Sizing options (tank ≥ 50 L/m²)

CollectorTank (L)Solar fractionkWh/yrkWh per m²
1 m²20023%785785
2 m²20040%1,365683
3 m²20053%1,792597
4 m² ◀20061%2,097524
5 m²25068%2,312462
6 m²30072%2,451408
8 m²40077%2,618327
10 m²50080%2,731273
12 m²60082%2,813234
  • Climate inputs are long-term monthly NASA POWER irradiance and temperatures for 44.43, 26.1 (default-site values embedded for pre-rendering), converted to a 45° tilt at 180° azimuth (Hay–Davies). Mains-water temperature follows a smoothed air temperature trailing by one month.
  • Calculation uses the monthly f-chart approach for liquid systems, with adjustments for tank size and hot-water temperature. The collector has F_R(τα) = 0.693 and F_R·U_L = 3.92 W/m²K.
  • Flat-plate collectors were the f-chart's original target. Applied to evacuated tubes it still gives a decent estimate, normally within ±5 percentage points.

Why a collector is not sized like a PV array

Output from a solar thermal collector depends on what the house draws. A warm tank slows the collector down, and a tank at its set temperature stops it altogether. Klein, Beckman and Duffie devised the f-chart method to handle that feedback without hour-by-hour modelling. This calculator runs it completely, for liquid-based domestic hot-water setups.

It works month by month:

  1. Heating load. Energy to raise the daily hot-water draw from mains temperature to 45 °C, plus heat the tank loses while idle.
  2. Sunshine on the collector. NASA POWER long-term climate for your location, converted to your tilt and orientation.
  3. Two dimensionless numbers. X relates collector losses to the load and Y relates absorbed sunlight to it. Both are corrected for tank volume per m² of collector and for hot and cold water temperatures.
  4. Monthly solar fraction f. Taken from the f-chart correlation, then applied to the load.

Mains temperature tracks the air temperature but is damped and lagged roughly a month, much like water in buried pipes. Money saved is judged against your existing heater’s efficiency (or COP) and energy price, after deducting pump electricity.

Formulas

L = m_water × c_p × (45 °C − T_mains) + UA_tank × (T_tank − T_room) × Δt X = A × F_R'U_L × (100 °C − T_air) × Δt ÷ L × (V/A ÷ 75)^−0.25 × (11.6 + 1.18 T_w + 3.86 T_m − 2.32 T_a) ÷ (100 − T_a) Y = A × F_R'(τα) × H_T × N ÷ L f = 1.029 Y − 0.065 X − 0.245 Y² + 0.0018 X² + 0.0215 Y³ (0 ≤ f ≤ 1)

Collector test coefficients (η0, a1, a2 under EN ISO 9806) give F_R(τα) and F_R·U_L, adjusted for an average incidence-angle modifier and, with indirect loops, a heat-exchanger penalty.

A household of four near Bucharest

Four occupants at 50 L of 45 °C water daily need about 2,780 kWh of heat a year. Add roughly 630 kWh lost by a 200 L tank kept at 55 °C in a 15 °C room, and the load comes to 3,411 kWh.

Fit 4 m² of selective flat-plate collectors facing south at 45°, on an indirect glycol loop with 8% pipe losses. They deliver about 2,100 kWh a year, or 524 kWh per m², which makes the solar fraction 61%. Over the year the fraction swings between roughly 90% in July and August and 23% in December. Priced against electricity at €0.25/kWh, the saving is about €507 a year after 68 kWh of pump electricity. A €3,500 installation pays back in about seven years and avoids around 0.8 t of CO₂ annually.

Sizing runs into diminishing returns quickly. 2 m² gives 40%, 6 m² gives 72%, and 8 m² adds just 5 more points for 77%, while kWh per m² falls from 680 to 330.

What each result means

  • Solar fraction is how much of the year’s hot-water heat the sun supplies.
  • kWh per m² shows the productivity of each square metre. In Europe, 400–600 kWh/m² is normal for a well-sized home system; a lower figure suggests the array is too big.
  • Months near 100% solar warn of stagnation. The design has to survive heat that goes unused, through an expansion vessel, high-temperature glycol or a heat dump.
  • Storage per m² normally lands at 50–75 L/m². Far less invites overheating, far more keeps the water only lukewarm.

Typical values

Climate Collector per person Typical solar fraction Yield per m² (flat plate)
Northern Europe (55°N) 1.2–1.8 m² 40–55% 300–450 kWh
Central Europe (48–52°N) 1.0–1.5 m² 50–65% 350–500 kWh
SE Europe, northern US 0.9–1.2 m² 55–70% 450–600 kWh
Mediterranean, California 0.6–1.0 m² 70–85% 550–750 kWh
Sun Belt, Middle East 0.5–0.8 m² 80–95% 600–850 kWh

Practical pointers

  • Set collectors steeper than you would for PV, 45–60°, so summer excess and winter shortfall even out; the tilt angle calculator shows how.
  • Lag the cylinder and the pipework. Idle losses commonly consume 15–25% of the load, and a tank with a smaller UA raises the fraction one-for-one.
  • Keep the thermostat modest. Between 55 and 60 °C Legionella is kept in check; anything hotter increases losses and lowers collector efficiency.
  • Schedule showers and washing for later in the day, after the collector has heated the tank.
  • Weigh the PV alternative. Panels are cheap now, and a PV array running a heat-pump water heater can achieve similar savings with less pipework. The heat pump calculator and the solar panel calculator let you compare.

Limits of the model

The correlation behind f-chart was fitted to flat-plate collectors feeding a fully mixed tank; evacuated tubes, stratified tanks, thermosiphon and drain-back systems may differ by several percentage points. Averaged monthly climate hides year-on-year variation of ±5–10%. Daily hot-water use is assumed flat across the year. Neither shading, dirt on the glass nor control logic is modelled, and prices depend heavily on country and installer.

Method & assumptions

Each month's load L is the heat for hot water, namely kg of water, multiplied by 4.186 kJ/kg·K, multiplied by the rise from mains temperature to 45 °C, plus the tank's standby loss: UA × (T_tank − T_room) × hours. Collector irradiation comes from NASA POWER climatology on the tilted plane.

The f-chart (Klein, Beckman & Duffie, 1976) needs two dimensionless groups. The first is X = A·F_R'U_L·(100 − T_a)·Δt ÷ L, corrected for storage volume ((L/m² ÷ 75)^−0.25) and hot-water temperature. The second is Y = A·F_R'(τα)·H_T·N ÷ L. A fitted polynomial turns the pair into the solar fraction f, limited to 0–1: f = 1.029Y − 0.065X − 0.245Y² + 0.0018X² + 0.0215Y³. Solar energy is the sum of f·L, less pipe losses (× (1 − pipe losses)). Saving = solar ÷ backup efficiency × price − pump electricity.

Frequently asked questions

Collector area and tank volume for a home solar hot-water system?
Rule of thumb for central and southern Europe or the northern US: per person, 1–1.5 m² of flat-plate collector with 50–75 litres of storage. Where the sun is strong, 0.6–1 m² per person is enough. Four people usually end up with 4 m² and a 200–300 L cylinder. Expect that to cover 55–70% of annual water-heating energy at mid-latitudes, rising to 80–90% in the Sun Belt.
What is a sensible solar fraction target?
Most temperate-climate designs settle on 50–70% over the year. Going for 90% or more means a much larger array that sits idle and overheats in summer, so each extra kWh costs far more than the first ones. Cost-optimal designs in central Europe serve nearly all of the summer load but only 15–30% in winter.
Are vacuum tubes a better buy than flat panels?
Per m² of aperture, vacuum tubes lose less heat, which helps in cold weather and when high temperatures are needed. Flat plates convert light more efficiently and cost less, so for domestic hot water in mild or sunny places they match or beat tubes. The calculator lets you switch the collector type to compare for your location.
What will a solar water heater save me?
It saves whatever energy your existing heater would otherwise burn. Take 2,000 kWh of delivered heat a year. If an immersion heater was doing the job, that is 2,000 kWh of electricity, around €500 at €0.25/kWh. If an efficient gas boiler was doing it, the saving shrinks to about €200, and with a COP 2.8 heat-pump water heater it is roughly €180.
How does f-chart sizing work?
Researchers at the University of Wisconsin built it in the 1970s by fitting thousands of hourly simulations. Two dimensionless numbers drive the monthly result: X compares what the collector loses with the heating load, Y compares the sunshine it absorbs with that load. The method remains a standard tool for engineers designing solar water-heating plants.
Is solar hot water of any use between December and February?
Some, but the output is much smaller. In central Europe a well-tilted collector collects only a quarter to a third of its July irradiation in December, and mains water arrives colder. Antifreeze (glycol) circuits and drain-back layouts keep working below freezing, with the backup heater covering what the sun cannot.

Sources & references

  1. Klein, S.A., Beckman, W.A. & Duffie, J.A. (1976). A design procedure for solar heating systems. Solar Energy 18(2)
  2. Duffie, J.A. & Beckman, W.A. — Solar Engineering of Thermal Processes, 4th ed., Wiley (f-chart, chapter 20)
  3. IEA Solar Heating & Cooling Programme — Solar Heat Worldwide (annual market and yield report)
  4. NASA POWER — long-term monthly solar and meteorological climatology