Glossary · Mobility

AC charging (Level 1/2)

Electric-vehicle charging from an AC supply, where the car's own on-board charger rectifies the power to DC; usually 1.4–22 kW.

With AC charging the car does the heavy lifting: the station (EVSE) merely passes grid AC through and exchanges safety signals, while the vehicle's built-in OBC rectifies it to DC for the battery. Whatever is smallest of the grid connection, the cable and the OBC's rating caps the speed. Many models accept 7.4 or 11 kW; 22 kW is rarer.

Single-phase: P = V x I (230 V x 32 A ≈ 7.4 kW)
Three-phase: P = √3 x V_LL x I (√3 x 400 V x 16 A ≈ 11 kW; 32 A ≈ 22 kW)
US Level 2: 240 V x 48 A ≈ 11.5 kW
Charge time (h) ≈ energy needed (kWh) / (P x ~0.9 efficiency)

Two power classes are common. Level 1 means an ordinary 120 V socket (North America), good for 1.4–1.9 kW or about 6–8 km of added range every hour. Level 2 covers 208–240 V at 3.7–19.2 kW across the US and Canada, while European wall boxes reach 22 kW on three phases (Mode 3, Type 2 connector); European single-phase units are lower.

Connector standards: J1772 (Type 1) and NACS/SAE J3400 across North America, IEC 62196 Type 2 for Europe, GB/T for China. Expect 10–15% conversion and cable losses at low power, less at higher current.

Wherever parking at home is easy, about 70–80% of the energy EVs take comes via AC at the driveway or the office. The cars sit for hours, which makes the load flexible: it can be moved to cheap night hours or the solar midday, or curtailed on request under demand response.

Related terms

All terms →
  • DC fast charging

    EV charging at high power where the rectifier sits in the station, not the car, so DC flows straight to the battery; usually 50–400 kW and up.

  • Battery electric vehicle (BEV)

    A car or truck propelled purely by electric motors drawing on an on-board rechargeable battery, without any combustion engine.

  • Vehicle-to-grid (V2G)

    Two-way charging that lets a parked electric vehicle send battery energy back to the grid, acting as storage and providing grid services.

  • Demand response

    Changes in end users' electricity use, prompted by price signals or operator requests, that help balance the grid.

  • Power vs energy (kW vs kWh)

    Power in kW is the flow of energy at one moment, while energy in kWh is power added up over time. Capacity is stated in power, and output in energy.