Think of a nuclear station as a steam plant with an unusual boiler: a core of uranium fuel in which atoms split in a chain reaction that is kept under control. The turbines, generator and cooling towers could belong to any fossil plant. This guide covers the physics, the reactor designs in service, the reason a switched-off reactor still needs cooling, and what Generation III+ designs changed. Costs and the wider debate are in Nuclear Power: Pros and Cons.

What happens during fission

Fission starts when a uranium-235 nucleus captures a slow neutron. It becomes unstable and breaks into two lighter fragments, the fission products (isotopes of caesium, strontium, iodine and others). About 200 MeV is released per split, mostly as kinetic energy of the fragments, which becomes heat when they collide with nearby atoms. Two or three fresh neutrons also come out. If each fission leads, on average, to exactly one more, the reaction holds steady. Operators call that state critical; in a reactor the word just means stable, not hazardous. See also nuclear fission in the glossary.

Energy per fission ≈ 200 MeV ≈ 3.2 × 10⁻¹¹ J Atoms in 1 kg of U-235 = 1,000 g ÷ 235 g/mol × 6.022 × 10²³ ≈ 2.56 × 10²⁴ Heat from fully fissioning 1 kg U-235 ≈ 2.56 × 10²⁴ × 3.2 × 10⁻¹¹ J ≈ 8.2 × 10¹³ J ≈ 22.8 GWh (thermal) At 33% efficiency ≈ 7.5 GWh of electricity, about what 2,500 European homes use in a year Same heat from coal at 25 MJ/kg ≈ 3,300 tonnes

Only 0.711% of natural uranium is U-235. U-238 makes up the rest and rarely splits when hit by slow neutrons. So most reactors burn fuel enriched to 3–5% U-235, in the form of ceramic uranium dioxide pellets stacked inside zirconium-alloy tubes. Some U-238 captures a neutron and becomes plutonium-239, which fissions too, and by the end of its time in the core an assembly draws a good part of its energy from plutonium. Fuel manufacture has its own page, the nuclear fuel cycle guide.

Core components

Moderator. Fission neutrons start out fast, but U-235 captures slow (thermal) ones much more readily. A moderator made of light atoms slows them through collisions. Designs rely on light water, heavy water or graphite for this job.

Control rods. Neutron-absorbing rods, made of boron, cadmium, hafnium or silver-indium-cadmium, are pushed into the core to take neutrons out of play. Inserting them lowers power, and dropping them completely (a scram) ends the chain reaction within seconds. In PWRs, boric acid dissolved in the coolant also trims reactivity during a fuel cycle.

Coolant. Heat has to leave the core. Most reactors use water; carbon dioxide or helium cools gas-cooled designs, and fast reactors run on liquid sodium or lead.

Pressure vessel and containment. A light-water reactor core sits in a steel vessel with walls about 20–25 cm thick. A reinforced concrete containment building surrounds it, designed to keep radioactivity inside even after a break in the cooling circuit.

Water-moderated cores have a helpful trait, a negative temperature coefficient. As the core warms, the water thins out, slows fewer neutrons, and power drops without anyone acting.

Reactor types compared

Design Moderator / coolant Fuel Pressure, outlet temp. Where Share of fleet (approx.)
PWR (pressurised water) incl. VVER Light water / light water 3–5% enriched UO₂ ~155 bar, ~325 °C US, France, China, Russia, Korea, Japan ~70%
BWR (boiling water) Light water / light water 3–5% enriched UO₂ ~70 bar, ~285 °C US, Japan, Sweden, Finland ~15%
PHWR (CANDU) Heavy water / heavy water Natural uranium ~100 bar, ~310 °C Canada, India, Argentina, Romania ~10%
RBMK Graphite / boiling light water ~2% enriched ~70 bar Russia only (a few units left) under 2%
AGR / gas-cooled Graphite / CO₂ Enriched UO₂ ~40 bar, ~640 °C UK under 2%

The shares are rounded numbers based on IAEA PRIS. In a PWR the primary water never boils; it hands heat to steam generators, and a second, separate loop produces the steam, which keeps radioactive water away from the turbine. A BWR has one loop and so is simpler, though its turbine hall carries mild radioactivity while running. CANDU reactors take natural uranium, which works because heavy water captures very few neutrons, and can be refuelled while running. Chernobyl’s RBMK design behaved oddly at low power: with a positive void coefficient, steam bubbles pushed reactivity up where they should have pushed it down. With a poor control rod design and a badly managed test, this led to the 1986 disaster, and the surviving RBMKs were later modified.

Turning heat into power

Steam in a light-water reactor is at roughly 70 bar and 280–290 °C. An ultra-supercritical coal plant reaches 600 °C, so nuclear efficiency is lower, typically 33–37%. Take a big unit making 3,400 MW of heat: about 1,150 MW goes to the grid and roughly 2,250 MW is rejected into the sea, a river or cooling towers. Coastal sites are common for that reason.

With cheap fuel and costly construction, reactors usually run at full output. The fleet-wide average capacity factor is near 80%, while top US plants have averaged above 90% over two decades. French reactors, however, follow demand every day, ramping between about 50% and 100%, so baseload running is a choice and not a physical limit. Annual output follows from the capacity factor calculator.

Decay heat: switched off, still hot

Ending the chain reaction leaves a second heat source: fission products still in the fuel, which are radioactive and keep decaying.

Time after shutdown Decay heat (share of full thermal power) For a 3,400 MWth reactor
1 second ~6–7% ~220 MW
1 hour ~1.5% ~50 MW
1 day ~0.5% ~17 MW
1 week ~0.2% ~7 MW

Approximations from textbook decay curves. With no cooling, even 17 MW boils off water and overheats the fuel in hours. That was the story of Fukushima Daiichi in March 2011. A tsunami knocked out power to the cooling pumps in three units that had been operating. Spent fuel likewise sits for years in cooling pools before moving to dry casks; see Nuclear Waste: The Facts.

Layers of safety

Reactor safety is built on defence in depth: independent barriers and systems layered together, with the assumption that any one may fail at some point.

  • Physical barriers: the ceramic pellet, its metal cladding, the boundary of the coolant circuit and the outer containment.
  • Shutdown: control rods dropped by gravity or driven in, and boron injection as a backup.
  • Emergency core cooling: pumps for high-pressure and low-pressure injection, power-free accumulators holding borated water, and standby diesel generators.
  • Hydrogen control: recombiners that stop hydrogen from overheated cladding accumulating.
  • Filtered venting and core catchers, found in newer plants, so that releases stay limited even after a core melt.

Generation III+ designs

Reactors designed since the 1990s have extra redundancy, and several add passive safety, meaning gravity, natural circulation and stored pressure take the place of pumps and operator action.

Design Vendor Size (MWe) Passive or active Examples in operation
EPR EDF / Framatome ~1,650 Active, 4 redundant trains, core catcher Taishan 1–2 (China), Olkiluoto 3 (Finland, 2023), Flamanville 3 (France, grid 2024)
AP1000 Westinghouse ~1,100 Passive cooling for 72 h Sanmen, Haiyang (China), Vogtle 3–4 (US, 2023–2024)
APR1400 KEPCO / KHNP ~1,400 Mostly active Shin Kori, Saeul (Korea), Barakah 1–4 (UAE)
Hualong One (HPR1000) CNNC / CGN ~1,100 Active + passive Fuqing 5–6 (China), Karachi K-2/K-3 (Pakistan)
VVER-1200 Rosatom ~1,200 Active + passive Novovoronezh II, Leningrad II, Ostrovets (Belarus)

The first Western builds finished years late and billions over budget; Vogtle 3 and 4 together exceeded $30 billion. China and Korea have built faster, often in five to six years from first concrete. For compact designs, see Small Modular Reactors Explained.

Key points

  • The reactor only supplies heat: fission of U-235 (plus bred Pu-239) warms the water that drives a steam turbine.
  • Neutrons are slowed by the moderator and soaked up by control rods, while coolant carries the heat off. A water-cooled core weakens by itself when it warms.
  • Most reactors are PWRs, with BWRs, CANDUs and a few legacy types filling out the rest.
  • Because of decay heat, cooling must go on for days after shutdown and for years with spent fuel.

Ember reports about 2,770 TWh from nuclear in 2024, around 9% of world electricity. Which countries lean on nuclear most? The nuclear energy hub and the nuclear technology page show it, and profiles like France go deeper.

Calculators related to this topic

Frequently asked questions

How is electricity made in a nuclear reactor?
Splitting uranium nuclei (fission) gives off heat. The heat makes steam, either in the core itself or in a separate heat exchanger, and the steam drives a turbine and generator. Only the heat source is unusual; everything downstream looks like a fossil plant.
Is a nuclear explosion possible in a reactor?
No. Reactor fuel holds only about 3–5% uranium-235, against roughly 90% in weapons, and a reactor core cannot physically detonate like a bomb. Chernobyl's explosions came from steam and chemical reactions, which scattered radioactive material.
Why does a shut-down reactor still need cooling?
Radioactive fission products in the fuel go on decaying and giving off heat. Right after shutdown the decay heat equals 6–7% of full thermal power; it drops to about 1.5% in an hour and 0.5% in a day. Fuel can melt if cooling stays off for several hours, as it did at Fukushima in 2011.
How big is the global reactor fleet?
The IAEA PRIS and World Nuclear Association (2025) list roughly 415–440 operable units, the range reflecting whether idled Japanese reactors are counted, with about 375–395 GW net capacity. Their 2024 output made up some 9% of global electricity.
PWR versus BWR: what separates them?
In a pressurised water reactor the coolant is kept at about 155 bar, so it never boils, and separate steam generators make the steam. A boiling water reactor skips that step, letting water boil in the core at roughly 70 bar and sending the steam directly to the turbine. PWRs are around two-thirds of all reactors.
What is the efficiency of a nuclear plant?
Only about 33–37% of the thermal output of a light-water reactor becomes electricity, because its steam runs cooler than that of modern coal plants. A unit of 3,400 MW thermal therefore yields around 1,150 MW electric.

Sources & references

  1. IAEA — Power Reactor Information System (PRIS)
  2. World Nuclear Association — Nuclear Power Reactors
  3. U.S. NRC — Pressurized and boiling water reactors
  4. Ember — Global Electricity Review 2025
  5. IAEA — Nuclear Power Reactors in the World (Reference Data Series No. 2)

The figures in this guide are typical ranges taken from the listed sources, and your own values will vary with location, prices and equipment. For estimates specific to your site, use the linked calculators.