Which aircond horsepower suits your room, and what will it add to your bill?

Type in the size of your room and receive the aircond capacity it needs in BTU/h and HP (1.0, 1.5, 2.0 or 2.5 HP). You also get the kWh used and the true extra charge on your TNB bill if it runs every night.

Editable share link Branded PDF report Free · no sign-up

Results

A 1.0 HP (9,000 BTU/h) unit fits this room (calculated load 7,200 BTU/h). At 8 hours a day it adds roughly RM 51 to your monthly bill.
Recommended size
1.0 HP (9,000 BTU/h)
calculated load 7,200 BTU/h
Added to your monthly bill
50.92RM
55.7 sen for each extra kWh at your consumption level
Electricity per month
91kWh
Per night / day of use
1.7RM
3 kWh per day
Average power draw
381W
rated cooling 2.64 kW
Per year
611RM
Monthly cost for different daily hours (RM)

Inverter against non-inverter in this room

TypekWh per monthRM per monthRM per year
Inverter9150.92611
Non-inverter13777.19926

Aircond sizes for a standard room (2.7 m ceiling)

SizeBTU/hRoom area (m²)Room area (sq ft)
1.0 HP9,0000–160–170
1.5 HP12,00016–21170–227
2.0 HP18,00021–32227–340
2.5 HP24,00032–42340–453
3.0 HP28,00042–49453–529
  • The cost is the gap between your monthly bill with this aircond and without it, worked out on the TNB tariff as of 2026-11-14, so tiers, rebates and tax are all reflected.
  • Sizing allows roughly 600 BTU/h for each m² of floor under a 2.7 m ceiling, then adjusts for sun, roof exposure, occupants and heat sources. A poorly insulated room or one with lots of glass may call for the next size up.
  • Setting the thermostat to 24–25 °C rather than 20 °C usually trims consumption by somewhere between a fifth and a third.

Size first, then the monthly cost

Air conditioning tends to be the biggest single load on a Malaysian bill. The tool works in three steps. A cooling load in BTU/h comes first, from floor area, ceiling height, sun, roof exposure, occupants and heat sources like cooking. Next it picks the smallest standard Malaysian size that copes (1.0, 1.5, 2.0, 2.5 or 3.0 HP) and turns its efficiency and typical load into average electricity use. Last, the extra kWh are priced on the real TNB, SESB or Sarawak Energy domestic tariff.

Formula

Load (BTU/h) = area (m²) × 600 × (ceiling height ÷ 2.7) × sun factor × 1.15 if under the roof, + 600 per person above two, + 4,000 for a kitchen Average power (kW) = unit cooling capacity (kW) × average load ÷ efficiency (CSPF or EER) kWh per month = average power × hours per day × days Monthly cost = TNB bill (household + aircond) − TNB bill (household only)

Hot-humid countries use 600 BTU/h per m², a figure that tracks retailer advice (1.0 HP suits the usual 3 × 4 m bedroom). One kW equals 3,412 BTU/h.

Instead of kWh times a flat rate, cost is the difference between two full bills. The reason is the July 2025 TNB tariff: more kWh may move you to a lower Energy Efficiency Incentive band, or over the protection threshold where AFA, the retail charge and SST start to apply.

Example: 12 m² bedroom

The defaults are a 3 × 4 m room with normal sun, two occupants and a 2.7 m ceiling.

  • 12 m² × 600 = 7,200 BTU/h. A 1.0 HP unit (9,000 BTU/h) covers that.
  • Its 2.64 kW of cooling, divided by an efficiency of 4.5 and applied at 65% average load, means about 380 W from the socket.
  • Over 30 nights of 8 hours: 0.38 × 8 × 30 ≈ 91 kWh.
  • Other appliances use 350 kWh, so the comparison is 350 kWh against 441 kWh on the TNB tariff. The difference is about RM51 per month (roughly RM1.70 a night), which is 56 sen for each extra kWh, double the 27 sen energy charge, since the home slips from the 21 sen EEI band to the 14.5 sen band.

Reading the results

  • Recommended size: the rating to look for in shops.
  • Extra on your bill: higher for a household that already uses a lot.
  • Average power draw: the realistic figure, well under the nameplate input, because inverters run at part load overnight.
  • Inverter vs non-inverter: the same sums at efficiency 4.5 and 3.0.

Sizes

  • 1.0 HP: 9,000 BTU/h, 2.6 kW. Bedroom up to about 15 m².
  • 1.5 HP: 12,000 BTU/h, 3.5 kW. Master bedroom, 15–21 m².
  • 2.0 HP: 18,000 BTU/h, 5.3 kW. Small living room, 21–31 m².
  • 2.5 HP: 24,000 BTU/h, 7.0 kW. Living and dining, 31–42 m².
  • 3.0 HP: 28,000 BTU/h, 8.2 kW. Open-plan areas up to about 49 m².

Saving tips

  • Run 24–25 °C with the fan on and avoid “turbo” at 16–18 °C.
  • Wash filters every few weeks and service the unit yearly, as dirty coils lose efficiency.
  • Close west-window curtains in the afternoon and insulate the roof space on top floors.
  • Pick an inverter model with a high star rating on the Energy Commission label, and use a timer to stop it once mornings cool down.
  • With rooftop solar, late-afternoon pre-cooling uses your own power; see the Solar ATAP calculator.

Limits

This assumes a normally built Malaysian room; glass walls, thin insulation, many appliances or open doors need more, and large spaces deserve a professional heat-load survey. Running cost is an estimate good to about ±25%. See the whole bill in the TNB bill calculator, or use the air conditioner cost calculator for other countries.

Method & assumptions

Sizing: cooling load (BTU/h) = floor area × 600 × (ceiling height ÷ 2.7) × sun factor (0.9 shaded, 1.0 normal, 1.15 sunny). Multiply by 1.15 if the room is directly under a roof, then add 600 BTU/h for every person beyond two and 4,000 BTU/h for a kitchen. The smallest standard model that reaches 95% of that load is selected from 9,000 / 12,000 / 18,000 / 24,000 / 28,000 BTU/h, which are sold as 1.0 / 1.5 / 2.0 / 2.5 / 3.0 HP.

Energy: mean electrical power = rated cooling (kW) × mean load ÷ efficiency (CSPF or EER), and kWh = power × hours × days. Cost: we price your household consumption with the aircond and subtract the price without it, using the present domestic tariff of TNB, SESB or Sarawak Energy.

Frequently asked questions

How do I choose an aircond size for a room in Malaysia?
Take floor area in m², multiply by 600 and you have BTU/h for a 2.7 m ceiling. That puts a small bedroom (up to roughly 15 m², 160 sq ft) at 1.0 HP, or 9,000 BTU/h. Next come 1.5 HP at 12,000 BTU/h for about 21 m², then 2.0 HP at 18,000 BTU/h for about 31 m², and finally 2.5 HP at 24,000 BTU/h for about 42 m². A west-facing room, a top floor or a kitchen justifies going one size up.
How many BTU does 1 HP aircond give?
Look at the conversion shops use: 2.6 kW is sold as 1.0 HP (about 9,000 BTU/h). Likewise 3.5 kW is 1.5 HP (12,000 BTU/h), 5.3 kW is 2.0 HP (18,000 BTU/h) and 7 kW is 2.5 HP (24,000 BTU/h). The HP figure is merely a trade label and has nothing to do with the motor's mechanical horsepower.
What will a 1 HP aircond add to my bill after 8 hours a night?
An inverter 1.0 HP unit at 24–25 °C burns 2.5 to 3.5 kWh per 8-hour night, about 75 to 105 kWh over a month. For a home at 350 kWh already, the TNB bill climbs by around RM45 to RM67 monthly. Part of that comes from the Energy Efficiency Incentive rebate shrinking as consumption grows, which pushes the real price per kWh above a flat rate.
Are inverter airconds worth the extra money?
Usually, when the unit runs most nights. Its compressor ramps down rather than cycling. Seasonal efficiency (CSPF) is the telling number: 5 or more for good inverters, about 3 for a basic non-inverter. That gap trims running costs by a third or more. Buyers who use the unit every night usually recover the extra price in two to four years.
Which aircond temperature saves electricity?
Malaysian advice is typically 24 to 25 °C. Going up one degree cuts consumption by very roughly 5 to 10%. Pair it with a ceiling fan and you will not notice the warmer setting.
Does a larger aircond cool better?
No. Excess capacity chills the air fast and stops early, so humidity stays and the room feels clammy; non-inverter models also switch on and off more. Fit the size to the heat load and spend on efficiency instead.

Sources & references

  1. Energy Commission (Suruhanjaya Tenaga) — energy efficiency labelling of electrical equipment
  2. U.S. Department of Energy — Room air conditioners: sizing and efficiency
  3. IEA — The Future of Cooling
  4. TNB — Pricing & tariffs (residential)

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.