Home energy calculator

What size air conditioner do you need, and what will it cost to run?

Start with floor area, ceiling height, sun exposure, climate and the number of people in the room to get a cooling capacity in BTU and kW. The tool then uses the unit's SEER or EER to estimate the power it draws and its cost per hour, day, month and cooling season.

Editable share link Branded PDF report Free · no sign-up

Results

We recommend roughly 6,800 BTU/h (2 kW), and the closest standard size is 7,000 BTU. Over 8 h each day, running costs come to 0.37 €.
Seasonal cooling bill
€27.75
111 kWh over 75 days
Cost per hour
€0.046
0.18 kW average draw
Cost per day
€0.37
Cost per month of use
€11.10
Recommended size
6,800BTU/h
2 kW cooling · 0.57 tons
Unit used for costs
7,000BTU/h
2.05 kW · max input 0.34 kW
Efficiency (W/W)
6.1
= 20.8 BTU/Wh
CO₂ per year
39kg
Cooling cost over a season at different efficiencies
Daily cost as hours of use change

Rough sizing chart (typical room, warm climate)

Room areaBTU/hkW cooling
10 m² (108 ft²)2,7000.8
15 m² (161 ft²)4,1001.2
20 m² (215 ft²)5,5001.6
25 m² (269 ft²)6,8002
30 m² (323 ft²)8,2002.4
40 m² (430 ft²)10,9003.2
50 m² (538 ft²)13,6004
70 m² (753 ft²)19,1005.6
  • The basis is about 80 W/m² (25 BTU/h per ft²), then corrected for ceiling height, climate, sunshine, people (600 BTU/h for each one past the second) and kitchens (4,000 BTU/h extra), following ENERGY STAR guidance. Rooms with weak insulation can need 20–30% more.
  • Running cost = capacity ÷ efficiency × load factor × hours. A SEER figure already allows for part-load running. With an EER (full-load) rating, a load factor near 70% is a fairer assumption.

Sizing and running cost in one tool

Sizing starts from floor area at about 80 W per m² (roughly 25 BTU/h per ft²), which agrees with the ENERGY STAR room table. Ceiling height, climate (from mild northern Europe to Gulf-state heat) and sun then adjust it; the sun choices are shaded, average, west-facing glass, or a top floor beneath a roof. Each person past the second adds about 600 BTU/h (175 W), and a kitchen adds 4,000 BTU/h. The answer is rounded up to a catalogue size such as 5,000, 6,000, 7,000, 9,000, 12,000, 18,000 or 24,000 BTU.

Costing begins with input power, which is cooling output over efficiency. Enter whichever rating you have on hand, whether that is a European SEER in W/W, a US SEER or SEER2 in BTU/Wh, an EER, or a COP measured at full load. Because inverters seldom run flat out, the result is multiplied by an average load factor, 55% unless you change it, and then by daily hours, season length and tariff. Switch on the heating option to price winter use of a reverse-cycle unit.

The maths

Q_required (W) = area × 80 × (ceiling ÷ 2.5) × f_climate × f_sun + 175 × (people − 2) [+ 1,170 kitchen] BTU/h = W × 3.412

P_input (kW) = Q_unit (kW) ÷ efficiency (W/W) [US SEER or EER ÷ 3.412 → W/W] kWh/season = P_input × load factor × hours/day × days Cost = kWh × electricity price

Worked case: living room of 25 m²

The default room has 25 m² of floor, a 2.5 m ceiling, warm summers, average sun and two occupants. Required cooling comes to about 6,800 BTU/h (2.0 kW), and the nearest standard model is 7,000 BTU (2.05 kW).

At EU SEER 6.1 (A++), peak input is 2.05 ÷ 6.1 = 0.34 kW. At 55% average load the unit pulls about 0.18 kW. At €0.25/kWh this means €0.046 per hour, so €0.37 for 8 hours, or about €11 in a month. Over a 75-day season the unit uses 111 kWh (about €28) and emits about 39 kg of CO₂ if the grid gives 350 g/kWh.

Efficiency swings the result. In the chart, a 3 W/W portable or old window unit would cost €56 per season for identical cooling, whereas an 8.5 W/W premium unit comes to about €20.

What each result means

  • Season cost is the budgeting figure; adjust days of use for your climate.
  • Hourly, daily and monthly cost show whether overnight or all-day running is realistic.
  • Recommended size appears in BTU/h, kW and refrigeration tons (12,000 BTU/h each); enter a unit’s capacity to be told if it is too small, too large or close.
  • Efficiency (W/W) puts European and US ratings on one scale.

Efficiency by unit type

  • Portable single-hose models rate EER 2.0–2.6 W/W, so 3.5 kW of cooling takes 1.3–1.8 kW of electricity.
  • Older window units come in at EER 2.6–3.2 W/W (9–11 BTU/Wh) and draw 1.1–1.3 kW for that same 3.5 kW.
  • A basic A+ split is SEER 5.6–6.1 W/W, drawing 0.6–0.7 kW (less on a seasonal average).
  • Efficient A++/A+++ splits reach SEER 6.1–8.5+ W/W and need only 0.4–0.6 kW.
  • US central AC is rated SEER2 13.4–20 BTU/Wh, or 0.6–0.9 kW.

Lower the bill

  • Aim for 24–26 °C rather than 20 °C; each degree below costs roughly 6–10% more energy.
  • Fit awnings or exterior shutters on the west and south sides. Keeping sunlight out can lower the load more than a new unit does.
  • Prefer an inverter and leave it running steadily rather than blasting it on and off.
  • Wash filters monthly in season, since clogged ones noticeably hurt efficiency.
  • Panels and cooling work on the same hours. How well they match is shown by the solar panel calculator.
  • In winter the same split unit heats as an efficient heat pump. Check it against your present heating in the heat pump calculator.

Caveats

The sizing rule suits an ordinary, reasonably insulated room. Mostly glass facades, weak insulation or high internal heat (servers, crowds) call for a proper heat-gain method: Manual J in the US, EN 12831-style methods in Europe. Setpoint, humidity and open doors also shift consumption, and one load factor is only an average. The indoor unit’s standby draw, typically 1–5 W, is excluded; see the standby power calculator.

Method & assumptions

Capacity needed Q = area × 80 W/m² × (ceiling ÷ 2.5 m) × climate factor × sun factor, plus 175 W for each additional person (and 1.17 kW if the room is a kitchen). The result is rounded up to the next standard unit. Power drawn = Q ÷ efficiency, where a US SEER or EER given in BTU/Wh becomes W/W after dividing by 3.412. Energy = power × load factor × hours × days. For heating, energy = 50% of rated capacity × hours × days ÷ SCOP.

Frequently asked questions

Hourly running cost of an air conditioner?
Electricity price comes last. First get the input power (capacity ÷ efficiency), then scale it by the typical load. In a 2 kW (7,000 BTU) split rated SEER 6.1 that means about 0.2 kW on average, which at €0.25/kWh is near €0.05 per hour. Swap in a worn-out window model of equal capacity and the figure may triple.
How big an air conditioner does my room need?
Count on roughly 80 W per m² (25 BTU/h per ft²) when the ceiling is 2.5 m and the room is typical. Rooms of 15–20 m² then fit 5,000–6,000 BTU, 25–30 m² fits 7,000–9,000 BTU and 40–45 m² needs 12,000 BTU. Add capacity if the room gets strong sun, sits under the roof, doubles as a kitchen or holds more than two people.
SEER vs EER: how do they differ?
EER describes efficiency at a single full-load test point. SEER averages over a whole season, part-load running included, which is why it comes out higher. European labels quote SEER in W/W, where 6.1 or above earns A++. American labels use BTU/Wh, and dividing by 3.412 turns that into W/W. For the same unit, US SEER2 reads about 4–5% below the old SEER.
Should I buy the biggest unit I can?
No. A unit that is too large drops the temperature fast and shuts off before it has pulled out enough humidity, so the room ends up cold and damp. It also starts and stops more often, which wastes electricity and wears the compressor. Inverter models tolerate some excess better, and the target band is 85–140% of the calculated requirement.
What is the daily kWh use of an air conditioner?
Expect 1–3 kWh a day from a small inverter split of 2–2.5 kW if it runs 8 summer hours. A 3.5 kW model in hot weather may use 5–10 kWh. For equivalent cooling, portable or old window units frequently land at 8–15 kWh.
Is heating with an air conditioner cheaper?
Most of the time. Reverse-cycle models are air-to-air heat pumps whose seasonal COP of 3.5–5 turns one kWh of electricity into 3.5–5 kWh of heat. Resistance heaters cannot get close, and gas is frequently more expensive too.

Sources & references

  1. ENERGY STAR: Room air conditioner sizing guidance
  2. U.S. DOE: Room air conditioners
  3. European Commission: Energy labelling of air conditioners (Regulation 626/2011)
  4. IEA: The Future of Cooling