Sizing and running cost in one tool
Sizing starts from floor area at about 80 W per m² (roughly 25 BTU/h per ft²), which agrees with the ENERGY STAR room table. Ceiling height, climate (from mild northern Europe to Gulf-state heat) and sun then adjust it; the sun choices are shaded, average, west-facing glass, or a top floor beneath a roof. Each person past the second adds about 600 BTU/h (175 W), and a kitchen adds 4,000 BTU/h. The answer is rounded up to a catalogue size such as 5,000, 6,000, 7,000, 9,000, 12,000, 18,000 or 24,000 BTU.
Costing begins with input power, which is cooling output over efficiency. Enter whichever rating you have on hand, whether that is a European SEER in W/W, a US SEER or SEER2 in BTU/Wh, an EER, or a COP measured at full load. Because inverters seldom run flat out, the result is multiplied by an average load factor, 55% unless you change it, and then by daily hours, season length and tariff. Switch on the heating option to price winter use of a reverse-cycle unit.
The maths
P_input (kW) = Q_unit (kW) ÷ efficiency (W/W) [US SEER or EER ÷ 3.412 → W/W] kWh/season = P_input × load factor × hours/day × days Cost = kWh × electricity price
Worked case: living room of 25 m²
The default room has 25 m² of floor, a 2.5 m ceiling, warm summers, average sun and two occupants. Required cooling comes to about 6,800 BTU/h (2.0 kW), and the nearest standard model is 7,000 BTU (2.05 kW).
At EU SEER 6.1 (A++), peak input is 2.05 ÷ 6.1 = 0.34 kW. At 55% average load the unit pulls about 0.18 kW. At €0.25/kWh this means €0.046 per hour, so €0.37 for 8 hours, or about €11 in a month. Over a 75-day season the unit uses 111 kWh (about €28) and emits about 39 kg of CO₂ if the grid gives 350 g/kWh.
Efficiency swings the result. In the chart, a 3 W/W portable or old window unit would cost €56 per season for identical cooling, whereas an 8.5 W/W premium unit comes to about €20.
What each result means
- Season cost is the budgeting figure; adjust days of use for your climate.
- Hourly, daily and monthly cost show whether overnight or all-day running is realistic.
- Recommended size appears in BTU/h, kW and refrigeration tons (12,000 BTU/h each); enter a unit’s capacity to be told if it is too small, too large or close.
- Efficiency (W/W) puts European and US ratings on one scale.
Efficiency by unit type
- Portable single-hose models rate EER 2.0–2.6 W/W, so 3.5 kW of cooling takes 1.3–1.8 kW of electricity.
- Older window units come in at EER 2.6–3.2 W/W (9–11 BTU/Wh) and draw 1.1–1.3 kW for that same 3.5 kW.
- A basic A+ split is SEER 5.6–6.1 W/W, drawing 0.6–0.7 kW (less on a seasonal average).
- Efficient A++/A+++ splits reach SEER 6.1–8.5+ W/W and need only 0.4–0.6 kW.
- US central AC is rated SEER2 13.4–20 BTU/Wh, or 0.6–0.9 kW.
Lower the bill
- Aim for 24–26 °C rather than 20 °C; each degree below costs roughly 6–10% more energy.
- Fit awnings or exterior shutters on the west and south sides. Keeping sunlight out can lower the load more than a new unit does.
- Prefer an inverter and leave it running steadily rather than blasting it on and off.
- Wash filters monthly in season, since clogged ones noticeably hurt efficiency.
- Panels and cooling work on the same hours. How well they match is shown by the solar panel calculator.
- In winter the same split unit heats as an efficient heat pump. Check it against your present heating in the heat pump calculator.
Caveats
The sizing rule suits an ordinary, reasonably insulated room. Mostly glass facades, weak insulation or high internal heat (servers, crowds) call for a proper heat-gain method: Manual J in the US, EN 12831-style methods in Europe. Setpoint, humidity and open doors also shift consumption, and one load factor is only an average. The indoor unit’s standby draw, typically 1–5 W, is excluded; see the standby power calculator.
Method & assumptions
Capacity needed Q = area × 80 W/m² × (ceiling ÷ 2.5 m) × climate factor × sun factor, plus 175 W for each additional person (and 1.17 kW if the room is a kitchen). The result is rounded up to the next standard unit. Power drawn = Q ÷ efficiency, where a US SEER or EER given in BTU/Wh becomes W/W after dividing by 3.412. Energy = power × load factor × hours × days. For heating, energy = 50% of rated capacity × hours × days ÷ SCOP.
Frequently asked questions
Hourly running cost of an air conditioner?
How big an air conditioner does my room need?
SEER vs EER: how do they differ?
Should I buy the biggest unit I can?
What is the daily kWh use of an air conditioner?
Is heating with an air conditioner cheaper?
Sources & references
Embed this calculator
Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.