Carbon & climate calculator

Calculate a grid's carbon intensity from its generation mix

Derive the carbon intensity of an electricity grid in g CO₂/kWh from the generation mix, direct or lifecycle. Add transmission losses for a consumption-based factor and spot the sources behind the emissions.

Editable share link Branded PDF report Free · no sign-up

Results

This mix emits 447 g CO₂ for each kWh generated (direct combustion), or 476 g for each kWh consumed once 6% grid losses are included. Low-carbon sources provide 38% of generation. The biggest emitter is Coal (74% of emissions).
Grid emission factor
447g CO₂/kWh
direct combustion, measured at generation
Consumption factor
476g CO₂/kWh
including 6% losses
Direct combustion factor
447g CO₂/kWh
Lifecycle factor
436g CO₂e/kWh
Low-carbon share
38%
nuclear, renewables, bioenergy
Fossil share
62%
CO₂ per MWh consumed
0.476t
Generation mix
Share of the emission factor by source (g CO₂/kWh)

Emission factor for each source

SourceShareDirect (g/kWh)Lifecycle (g CO₂e/kWh)Contribution (g/kWh)
Coal35%950820332.5
Natural gas25%400490100
Oil2%74072014.8
Nuclear10%0120
Hydropower8%0240
Wind10%0110
Solar7%0480
Bioenergy2%02300
Other (geothermal, waste…)1%0380
  • Lifecycle numbers (g CO₂e/kWh) are IPCC AR5 medians: coal 820, gas combined cycle 490, biomass 230, utility solar 48 / rooftop 41, hydro 24, nuclear 12, onshore wind 11. Oil is a ballpark taken from the literature. Direct factors assume typical plant efficiencies; change them to suit your grid.
  • CO₂ from burning bioenergy is counted as biogenic (0 direct). Actual grid factors also depend on imports, how CHP is allocated and hour-by-hour dispatch.

Purpose

A grid’s emission factor, or carbon intensity, is the CO₂ emitted for each kWh delivered. The generation mix almost fully determines it: fossil fuels (coal, gas, oil) against low-carbon supply (nuclear, hydro, wind, solar and similar). The figure feeds national inventories, company carbon accounts, EV and heat-pump comparisons and scenario work on future grids.

Enter a generation mix and you get the factor on two bases. Direct combustion means stack emissions, the usual convention for inventories and Scope 2. Lifecycle uses IPCC AR5 medians and so includes the supply chain. Grid losses convert the generation factor into a consumption factor, and a chart reveals which sources dominate.

Calculation

Grid factor (g/kWh) = Σ share_i × factor_i (shares normalised to 100%)

Direct factor of a fossil plant = heat rate (GJ/kWh) × fuel CO₂ factor (g/GJ) coal ≈ 9.5 MJ/kWh × 94.6 g/MJ ≈ 900–950 g/kWh gas ≈ 7.2 MJ/kWh × 56.1 g/MJ ≈ 400 g/kWh

Consumption factor = generation factor ÷ (1 − T&D losses)

Lifecycle defaults come from IPCC AR5 medians (g CO₂e/kWh): onshore wind 11, nuclear 12, hydro 24, geothermal 38, utility solar 48, dedicated biomass 230, gas combined cycle 490, coal 820. Oil is absent from AR5, so an indicative literature value of 720 g/kWh stands in. Under Fossil plant factors you can edit the direct factors of coal, gas and oil.

Sample grid

Default grid, a generic one in transition: 10% nuclear, 8% hydro, 10% wind, 7% solar, 2% bioenergy, 1% other, and 35% coal, 25% gas, 2% oil.

  • Coal contributes 0.35 × 950 = 332.5 g/kWh, gas 0.25 × 400 = 100, oil 0.02 × 740 = 14.8.
  • Every other source emits nothing at the stack, leaving a direct factor of 447 g CO₂/kWh.
  • Add 6% grid losses and the consumption factor becomes 447 ÷ 0.94 = 476 g/kWh.
  • Coal provides 35% of the power but causes 74% of the emissions.
  • Counted over the lifecycle, the figure is about 436 g CO₂e/kWh, slightly lower since the AR5 coal median assumes a more efficient plant than the fleet default.

The presets give about 665 g/kWh for a coal-heavy grid, 340 for gas-dominated, near 25 for nuclear plus hydro and around 110 for high renewables.

Benchmark grids

Grid profile Countries as examples Rough intensity, g CO₂/kWh
Mostly hydro or nuclear Switzerland, Sweden, Norway, France 20–60
Strong renewables plus some gas Portugal, Denmark, United Kingdom, Spain 100–200
Fossil and renewables mixed United States, Italy, Germany 250–400
Mostly gas Algeria, Iran, Gulf states 400–550
Mostly coal Indonesia, India, Poland, South Africa 600–750

Figures move every year as coal closes and wind and solar grow. For up-to-date national numbers from Ember and Our World in Data, see the electricity CO₂ calculator.

Using the output

  • Grid emission factor is the generation-side figure most statistics quote.
  • Consumption factor applies to kWh metered at the customer, provided your reporting rules count losses.
  • Direct versus lifecycle reveals the weight of supply-chain emissions: gas rises (methane leakage and processing), and low-carbon sources get small non-zero values.
  • Contribution chart: shows what to replace first for the fastest cut. Nearly always, that is coal.

Caveats

Annual averages conceal hourly swings; a midday kWh on a sunny day can be half as carbon-intensive as an evening-peak one. Real factors also shift with imports and exports, how combined heat and power is allocated and the age of each plant. Marginal factors, which describe an extra kWh of demand, may differ greatly from the average. Company reporting should follow GHG Protocol factor rules; the Scope 2 emissions calculator covers that.

Method & assumptions

Add up Σ sharei × factori across sources to get the grid factor, after rescaling the shares to 100%. Direct factors take plant heat rate × fuel CO₂ factor (defaults: coal ≈ 950, gas ≈ 400, oil ≈ 740 g/kWh), while renewables and nuclear count as zero at the stack. Lifecycle factors are median values from IPCC AR5. A consumption factor then equals the generation factor ÷ (1 − T&D losses).

Frequently asked questions

How do you compute a grid emission factor?
Weight each source's emission factor (g CO₂ per kWh) by its share of generation, then sum. Example: 35% coal at 950 g/kWh plus 25% gas at 400 g/kWh, the remainder low-carbon, gives 0.35 × 950 + 0.25 × 400 ≈ 430–450 g/kWh measured at the stack.
Direct versus lifecycle emission factors?
Direct factors cover only what leaves the stack, which makes hydro, nuclear, wind and solar zero. Lifecycle factors add fuel mining and transport, manufacturing, construction, decommissioning and methane leaks. IPCC AR5 medians in g CO₂e/kWh: coal about 820, solar about 40–50, nuclear about 12, wind about 11.
Typical carbon intensity of a national grid?
The global mean is roughly 450–480 g CO₂ per kWh. Norway, France and Sweden, built on hydro or nuclear, stay under 50 g/kWh; coal-reliant India, South Africa and Poland sit near 600–750 g/kWh.
How do network losses change the factor?
Lines and transformers waste 5–8% of electricity as heat in many grids, and more in some countries. One kWh at the user's meter thus needs 1 ÷ (1 − losses) kWh at the plant, and the consumption-based factor is generation factor ÷ (1 − losses).
Coal's lifecycle value is below its direct value here. Why?
The 820 g CO₂e/kWh AR5 median stems from a modern, fairly efficient coal plant, while the 950 g/kWh default direct factor reflects an average existing fleet including older units. Where your coal plants are newer, or burn lignite, change the direct factor.
Does bioenergy count as zero-emission?
Biogenic CO₂ at the stack is reported on its own and most grid factors count it as zero because plants took it up. Over a lifecycle, dedicated biomass is often near 230 g CO₂e/kWh (IPCC AR5 median), strongly dependent on feedstock and land use.

Sources & references

  1. IPCC AR5 WGIII Annex III — Technology-specific cost and performance parameters (lifecycle emissions)
  2. UNECE — Life Cycle Assessment of Electricity Generation Options (2021)
  3. Ember — Global Electricity Review and data explorer
  4. IPCC 2006 Guidelines, Vol. 2 Energy — fuel CO₂ emission factors

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.