Purpose
A grid’s emission factor, or carbon intensity, is the CO₂ emitted for each kWh delivered. The generation mix almost fully determines it: fossil fuels (coal, gas, oil) against low-carbon supply (nuclear, hydro, wind, solar and similar). The figure feeds national inventories, company carbon accounts, EV and heat-pump comparisons and scenario work on future grids.
Enter a generation mix and you get the factor on two bases. Direct combustion means stack emissions, the usual convention for inventories and Scope 2. Lifecycle uses IPCC AR5 medians and so includes the supply chain. Grid losses convert the generation factor into a consumption factor, and a chart reveals which sources dominate.
Calculation
Direct factor of a fossil plant = heat rate (GJ/kWh) × fuel CO₂ factor (g/GJ) coal ≈ 9.5 MJ/kWh × 94.6 g/MJ ≈ 900–950 g/kWh gas ≈ 7.2 MJ/kWh × 56.1 g/MJ ≈ 400 g/kWh
Consumption factor = generation factor ÷ (1 − T&D losses)
Lifecycle defaults come from IPCC AR5 medians (g CO₂e/kWh): onshore wind 11, nuclear 12, hydro 24, geothermal 38, utility solar 48, dedicated biomass 230, gas combined cycle 490, coal 820. Oil is absent from AR5, so an indicative literature value of 720 g/kWh stands in. Under Fossil plant factors you can edit the direct factors of coal, gas and oil.
Sample grid
Default grid, a generic one in transition: 10% nuclear, 8% hydro, 10% wind, 7% solar, 2% bioenergy, 1% other, and 35% coal, 25% gas, 2% oil.
- Coal contributes 0.35 × 950 = 332.5 g/kWh, gas 0.25 × 400 = 100, oil 0.02 × 740 = 14.8.
- Every other source emits nothing at the stack, leaving a direct factor of 447 g CO₂/kWh.
- Add 6% grid losses and the consumption factor becomes 447 ÷ 0.94 = 476 g/kWh.
- Coal provides 35% of the power but causes 74% of the emissions.
- Counted over the lifecycle, the figure is about 436 g CO₂e/kWh, slightly lower since the AR5 coal median assumes a more efficient plant than the fleet default.
The presets give about 665 g/kWh for a coal-heavy grid, 340 for gas-dominated, near 25 for nuclear plus hydro and around 110 for high renewables.
Benchmark grids
| Grid profile | Countries as examples | Rough intensity, g CO₂/kWh |
|---|---|---|
| Mostly hydro or nuclear | Switzerland, Sweden, Norway, France | 20–60 |
| Strong renewables plus some gas | Portugal, Denmark, United Kingdom, Spain | 100–200 |
| Fossil and renewables mixed | United States, Italy, Germany | 250–400 |
| Mostly gas | Algeria, Iran, Gulf states | 400–550 |
| Mostly coal | Indonesia, India, Poland, South Africa | 600–750 |
Figures move every year as coal closes and wind and solar grow. For up-to-date national numbers from Ember and Our World in Data, see the electricity CO₂ calculator.
Using the output
- Grid emission factor is the generation-side figure most statistics quote.
- Consumption factor applies to kWh metered at the customer, provided your reporting rules count losses.
- Direct versus lifecycle reveals the weight of supply-chain emissions: gas rises (methane leakage and processing), and low-carbon sources get small non-zero values.
- Contribution chart: shows what to replace first for the fastest cut. Nearly always, that is coal.
Caveats
Annual averages conceal hourly swings; a midday kWh on a sunny day can be half as carbon-intensive as an evening-peak one. Real factors also shift with imports and exports, how combined heat and power is allocated and the age of each plant. Marginal factors, which describe an extra kWh of demand, may differ greatly from the average. Company reporting should follow GHG Protocol factor rules; the Scope 2 emissions calculator covers that.
Method & assumptions
Add up Σ sharei × factori across sources to get the grid factor, after rescaling the shares to 100%. Direct factors take plant heat rate × fuel CO₂ factor (defaults: coal ≈ 950, gas ≈ 400, oil ≈ 740 g/kWh), while renewables and nuclear count as zero at the stack. Lifecycle factors are median values from IPCC AR5. A consumption factor then equals the generation factor ÷ (1 − T&D losses).
Frequently asked questions
How do you compute a grid emission factor?
Direct versus lifecycle emission factors?
Typical carbon intensity of a national grid?
How do network losses change the factor?
Coal's lifecycle value is below its direct value here. Why?
Does bioenergy count as zero-emission?
Sources & references
Embed this calculator