Every industry invented its own energy unit, and none of them gave way. Meters and bills run on kilowatt-hours, physicists use joules, American heating uses BTU, gas suppliers bill in therms or cubic metres, statisticians count tonnes of oil equivalent, and oil traders think in barrels. Below you will find the conversions people actually need, plus the two distinctions behind most mistakes, namely the gap between power and energy and the gap between gross and net heating value. Worked examples at the end cover a gas bill, a car and a whole country. If you only need a single conversion, the energy unit converter is faster.
Energy and power are not the same thing
Energy is a quantity, the ability to do work. Power is the speed at which energy moves. Mixing these up is the most frequent mistake in energy writing.
- A kW describes intensity. Examples are a 400 W solar panel, a 2 kW heater, a 7 kW EV charger and a 1 GW reactor.
- A kWh describes a total, such as 10 kWh used in a day, 3,500 kWh in a year or 100 TWh a year for a mid-sized country.
You will often see “kW per hour”. It is wrong, because a kWh is already kW multiplied by hours. See kW vs kWh for a longer explanation.
SI prefixes in energy
- kilo (k), 10³: household meters read in kWh.
- mega (M), 10⁶: MWh in wholesale trading and for big buildings; MJ for the heat content of fuels.
- giga (G), 10⁹: GWh for a power plant’s monthly output; GJ for district heat and gas trading.
- tera (T), 10¹²: TWh for a nation’s yearly electricity.
- peta (P), 10¹⁵: PJ or PWh in national energy balances.
- exa (E), 10¹⁸: EJ for world primary energy, on the order of 600 EJ per year.
Watch the case of the letter: mW is a milliwatt, MW a megawatt, and the two differ by a factor of a billion.
Energy conversion table
Where a factor is not exact by definition, it is rounded to four significant figures.
| One of… | kWh | MJ | BTU | Also equals |
|---|---|---|---|---|
| 1 kWh | 1 | 3.6 | 3,412 | 860 kcal |
| 1 MJ | 0.2778 | 1 | 947.8 | 238.8 kcal |
| 1 BTU (IT) | 0.000293 | 0.001055 | 1 | 1,055 J |
| 1 therm (US/UK) | 29.31 | 105.5 | 100,000 | — |
| 1 MMBtu | 293.1 | 1,055 | 1,000,000 | 10 therms |
| 1 kcal | 0.001163 | 0.004187 | 3.968 | 4,186.8 J |
| 1 toe (IEA, tonne of oil equivalent) | 11,630 | 41,868 | 39.68 million | 10 Gcal |
| 1 tce (coal equivalent, per tonne) | 8,141 | 29,308 | 27.78 million | 7 Gcal |
| 1 boe (barrel of oil equivalent) | ≈1,700 | ≈6,120 | ≈5.8 million | slightly different definitions exist |
| 1 quad | 2.931 × 10¹¹ | 1.055 × 10¹² | 10¹⁵ | used in US national statistics |
| 1 EJ | 2.778 × 10¹¹ (277.8 TWh) | 10¹² | 9.478 × 10¹⁴ | ≈ 0.948 quad |
Power conversion table
| One of… | W | kW | Also equals |
|---|---|---|---|
| 1 kW | 1,000 | 1 | 3,412 BTU/h, or 1.341 mechanical hp |
| 1 mechanical horsepower (550 ft·lbf/s) | 745.7 | 0.7457 | — |
| 1 PS or CV (metric horsepower) | 735.5 | 0.7355 | — |
| 1 refrigeration ton | 3,517 | 3.517 | 12,000 BTU/h |
| 1 BTU/h | 0.2931 | 0.000293 | — |
| 1 MW | 10⁶ | 1,000 | — |
Air conditioners in North America carry ratings in “tons” or BTU/h. Take a 12,000 BTU/h model: it removes about 3.5 kW of heat, but at a coefficient of performance of 3 it draws only around 1.2 kW of electricity.
How much energy is in a fuel?
Treat these as typical figures, since real calorific values shift with grade and origin. LHV is the lower (net) heating value, HHV the higher (gross) one.
| Quantity | Fuel | LHV, kWh | HHV, kWh | LHV, MJ |
|---|---|---|---|---|
| 1 m³ (standard) | Natural gas | 9.5–10.0 | 10.5–11.2 | 34–36 |
| 1 kg | Natural gas | ≈13.1 | ≈14.5 | ≈47 |
| 1 litre | Petrol / gasoline | ≈8.9 | ≈9.5 | ≈32 |
| 1 litre | Diesel / heating oil | ≈10.0 | ≈10.7 | ≈36 |
| 1 litre | LPG (propane) | ≈6.6 | ≈7.1 | ≈24 |
| 1 kg | LPG (propane) | ≈12.8 | ≈13.9 | ≈46 |
| 1 litre | Jet fuel (kerosene) | ≈9.5 | ≈10.2 | ≈34 |
| 1 kg | Hard coal | 6.4–8.1 | 6.7–8.4 | 23–29 |
| 1 kg | Lignite | 2.2–4.2 | 2.6–4.6 | 8–15 |
| 1 kg | Wood pellets | ≈4.8 | ≈5.2 | ≈17 |
| 1 kg | Firewood (20% moisture) | ≈4.0 | — | ≈14.4 |
| 1 kg | Hydrogen | 33.3 | 39.4 | 120 |
| 1 kg | Uranium (LWR fuel, burned) | on the order of 10⁶ kWh thermal | — | — |
Gross versus net: HHV and LHV
Hydrogen in a fuel burns to water vapour. If that vapour condenses, it gives back latent heat, which HHV counts and LHV leaves out. Condensing boilers capture part of it, so on an LHV basis they can report an “efficiency” over 100%. Before you compare prices, efficiencies or fuel tables, find out which basis each uses; mixing them causes errors of 5–11%.
Worked examples
1. Turning gas volume into kWh
Say the meter records 1,200 m³ over a year. Your supplier states a gross calorific value of 39.5 MJ/m³ and applies a volume correction factor of 1.02.
At €0.10/kWh the bill is about €1,343. Next, set it against a heat pump. A boiler at 0.90 efficiency turned that gas into roughly 12,090 kWh of useful heat, and a seasonal COP of 3.2 would supply the same heat from about 3,780 kWh of electricity. Try your own tariffs in the heating cost comparison calculator.
2. Petrol against electricity over 100 km
A petrol car that uses 6.5 L/100 km burns 6.5 × 8.9 ≈ 58 kWh of fuel per 100 km. An average EV draws 15–20 kWh/100 km at the socket, roughly a third. Electric drivetrains deliver 80–90% of battery energy to the wheels, while a petrol engine manages 20–35%.
3. Putting a national grid in scale
Take a country that generates 60 TWh a year. Its average output is 60,000,000 MWh ÷ 8,760 h ≈ 6.85 GW. One 1 GW nuclear plant at a 90% capacity factor yields 1 × 8,760 × 0.9 ≈ 7.9 TWh a year, around 13% of that country’s supply. Why that 90% figure matters is covered in the capacity factor guide.
4. From energy to CO₂
How much CO₂ you emit depends on the fuel and on how you burn it. Gas combustion releases roughly 0.18–0.20 kg CO₂ for each kWh of fuel (about 0.20 per LHV kWh, about 0.18 per HHV kWh). Electricity from the grid emits under 0.05 kg/kWh in Norway, France and Sweden, and over 0.7 kg/kWh on coal-heavy systems. The electricity CO₂ calculator gives the figure for your country, and the rankings put grids side by side.
Three ways to count primary energy
Any statement like “solar supplies X% of primary energy” rests on an accounting choice. Three are in common use.
- Physical energy content (used by the IEA and Eurostat): a kWh of wind, solar or hydro power is booked as 1 kWh of primary energy, while nuclear is booked as the heat the reactor produces, about 3 kWh per kWh of electricity.
- Substitution method (used by the Energy Institute Statistical Review and older BP reviews): every renewable kWh is valued as the fossil fuel it displaces, roughly 2.5 kWh of primary energy at about 40% efficiency.
- Direct or final energy (common in climate and transition studies): only final energy is compared.
The physical method makes wind and solar look smaller than the services they end up providing, and substitution makes them look bigger. Both are defensible since each answers a different question, so say which one you used whenever you give a share.
Rules of thumb
- 1 kWh ≈ 3.6 MJ ≈ 3,412 BTU ≈ 860 kcal
- Natural gas: 1 m³ ≈ 10–11 kWh on a gross basis.
- Road fuels: diesel ≈ 10 kWh per litre, petrol ≈ 9 kWh per litre.
- Hydrogen: 1 kg ≈ 33 kWh (LHV), which you can test in the green hydrogen calculator.
- 1 toe ≈ 11.6 MWh and 1 boe ≈ 1.7 MWh.
- A plant running at 1 GW for a full year delivers 8.76 TWh.
- 1 EJ ≈ 278 TWh
- Cooling: 1 kW ≈ 3,412 BTU/h ≈ 0.28 refrigeration tons.
To see the units used on real figures, open the national energy balances in the country profiles or pick any location on the Energy Explorer, which shows solar and wind resource in kWh and W/m².
Calculators related to this topic
Frequently asked questions
What is a therm worth in kWh?
What is the kWh content of petrol and diesel per litre?
What separates primary energy from final energy?
What is a toe, or tonne of oil equivalent?
How do HHV and LHV compare?
Are kilowatts and kilowatt-hours the same thing?
Sources & references
- BIPM (2019). The International System of Units (SI Brochure), 9th edition
- IEA — Unit converter and glossary (World Energy Balances documentation)
- U.S. EIA — Energy conversion calculators and heat content of fuels
- Eurostat — Energy statistics: conversion factors and calorific values (Energy Statistics Manual, IEA/Eurostat/OECD 2005)
- UK DESNZ — Greenhouse gas reporting: conversion factors (fuel properties)
The figures in this guide are typical ranges taken from the listed sources, and your own values will vary with location, prices and equipment. For estimates specific to your site, use the linked calculators.