Bio, geo & hydrogen calculator

Green hydrogen: how much an electrolyzer makes and what it costs per kg (LCOH)

Size an alkaline, PEM or SOEC electrolyzer and see the tonnes of hydrogen produced, water and electricity consumed and the cost of each kilogram, with stack replacements, degradation and a capacity-factor sensitivity chart.

Editable share link Branded PDF report Free · no sign-up

Results

Running 10 MW for 4,818 h/yr gives 884 t of hydrogen annually. The levelized cost is 4.52 €/kg (largest component: Electricity), lower than your sale price of 6 €/kg, so you keep a margin.
Hydrogen production
884t/yr
2,422 kg/day on average · 183 kg/h at full load
Levelized cost (LCOH)
4.52€/kg
136 €/MWh (LHV)
Electricity used
48.2GWh/yr
54.5 kWh/kg with degradation counted
Efficiency
61.2%
LHV · 72.3% HHV
Water consumption
13,262m³/yr
15 L/kg (stoichiometric 8.9)
Oxygen by-product
7,020t/yr
Stack replacements
1
every 16.6 years (80,000 h)
Total capex
€16,000,000
1,600 €/kW
Project NPV at your sale price
€15,247,042
6 €/kg, 7% WACC
CO₂ avoided vs grey H₂
8,841t/yr
≈10 kg CO₂ per kg from SMR without capture
Equivalent uses
7,368 FCEVs
equal to 5,013 t of ammonia · 2,959 m³ of diesel
LCOH breakdown
LCOH by capacity factor

Electrolyzer types (typical 2023–2025 figures)

TechnologySystem kWh/kgEfficiency (LHV)Stack life (h)Installed capex (€/kW)Notes
Alkaline (AEL)50–5561–67%60,000–90,0001,400–2,000proven and cheapest, ramps up more slowly
PEM52–5857–64%50,000–80,0001,700–2,500small footprint, quick response, needs iridium/platinum
SOEC37–42 + heat75–85%20,000–40,0002,500–4,000+runs hot, works best with waste heat or steam
AEM50–5758–66%<30,000early marketno PGMs, small units
  • Total up O&M, electricity, water, heat, capex × CRF and PV of stack replacements × CRF, then divide by the kg produced per year to get LCOH. The calculation leaves out taxes, grid fees, storage, transport and subsidies.
  • A real plant seldom holds one flat capacity factor. Variable renewables bring minimum-load limits and ramp rates that trim output; buffer storage or a top-up from the grid lifts utilisation again.
  • Capex figures span a wide band and shift fast. Alkaline systems from China are quoted far below installed costs in the West. For current numbers, see the latest IEA Global Hydrogen Review.

From electrons to LCOH

Water is split into hydrogen and oxygen by an electrolyzer powered with renewable electricity. Physics sets a fixed minimum of 39.4 kWh per kg. Cost is another matter, and it depends on electrolyzer efficiency and price, annual operating hours and the electricity tariff. The calculator treats them together in four steps:

  1. Output. Electrolyzer power × operating hours (set by the capacity factor of your supply) ÷ specific energy use gives kg per year. Stack degradation raises consumption over a stack’s life, so the tool uses the lifetime average.
  2. Inputs and by-products. Water, oxygen output and, with SOEC, steam.
  3. Cost per kg (LCOH). Capex is spread across the years by the capital recovery factor at your WACC, and stack replacements get the same treatment after discounting to the present. Then come fixed O&M, electricity, compression, water and heat, and the total is divided by yearly output.
  4. Sensitivity. LCOH is plotted against capacity factor for three power prices, which shows the cheap-but-intermittent versus expensive-but-firm trade-off better than a table.

Equations

H₂ (kg/yr) = P (MW) × 8,760 × CF × 1,000 / SEC (kWh/kg) Efficiency (LHV) = 33.33 / SEC Efficiency (HHV) = 39.41 / SEC Water = H₂ × L/kg (8.94 stoichiometric) O₂ ≈ 7.94 × H₂ CRF = r(1+r)ⁿ / ((1+r)ⁿ − 1) LCOH = (Capex × CRF + PV(stack replacements) × CRF + O&M + E × price + water + heat) / H₂

Case study: 10 MW alkaline, wind–solar PPA

Default setup: a 10 MW alkaline electrolyzer (52 kWh/kg new) on a hybrid solar and wind supply, 55% capacity factor, €45/MWh.

  • Roughly 4,820 full-load hours a year and 48 GWh of electricity.
  • Degradation of 0.12%/1,000 h lifts lifetime-average use to about 54.5 kWh/kg (61% LHV efficiency). The plant makes about 880 tonnes of hydrogen yearly, i.e. 2.4 t daily.
  • Water need is about 13,000 m³, with 7,000 t of oxygen released.
  • Capex at €1,600/kW totals €16 million; one stack is replaced after about 16–17 years.
  • LCOH ≈ €4.5/kg: electricity €2.45, capital €1.55, O&M €0.36, stack replacement €0.12 and water €0.03 per kg.

Priced at €6/kg, the hydrogen gives an NPV near +€15 million. With the 1 MW PEM on solar preset, LCOH tops €10/kg because the plant is small, capex is higher and capacity factor is only 22%. The 2030 target preset (€700/kW, €25/MWh) illustrates the roughly €2/kg that policymakers have in view.

Reading the results

  • Production is given in tonnes per year, as a daily mean, and as hourly output at full load.
  • LCOH should be weighed against grey hydrogen (about 1–3 per kg), subsidy auction prices, or whatever fuel is being displaced; the per-MWh LHV figure lines it up with natural gas.
  • Cost breakdown: when electricity dominates, work on efficiency and power price; when capital does, raise utilisation.
  • Sensitivity chart: each curve drops sharply at low capacity factors, then flattens past 50–60%. The best spot trades cheaper intermittent power against idle capital.

Technology comparison

Electrolyzer type Energy per kg, system level LHV efficiency Stack lifetime Installed capex, 2023–24
Alkaline (AEL) 50–55 kWh/kg 61–67% 60,000–90,000 h 1,400–2,000 per kW
PEM 52–58 kWh/kg 57–64% 50,000–80,000 h 1,700–2,500 per kW
SOEC 37–42 kWh/kg + heat ~75–85% incl. heat 20,000–40,000 h 2,500–4,000+ per kW
Anion exchange membrane, AEM 50–57 kWh/kg 58–66% < 30,000 h early market

Rules of thumb: 1 kg H₂ = 33.3 kWh (LHV) = 39.4 kWh (HHV) ≈ 11.1 Nm³. Fuel-cell cars use about 0.8–1 kg per 100 km; one tonne of hydrogen makes about 5.7 t of ammonia.

Ways to cut LCOH

  • Use the plant more. Mixing wind and solar, or topping up from the grid, can lower LCOH even if average power costs more.
  • Build renewables larger than the electrolyzer, so the latter spends more hours at full load.
  • Sell by-products. Selling oxygen or recovered low-temperature heat can lower cost by a few percent.
  • Watch stack lifetime and degradation, since a longer-lived stack may skip an expensive replacement.
  • Count compression and storage. Hydrogen delivered at 350–700 bar, or as a liquid, needs another 2–12 kWh/kg (set in the compression field) and storage on top.
  • Supply side: the wind farm calculator and the solar panel calculator model the power source.

Model limits

The model holds capacity factor and power price constant. Real renewable supply fluctuates, and limits on minimum load, ramping, storage and offtake reduce effective utilisation. Not modelled: taxes, grid fees, land, financing structure, transport and subsidies. Capex changes fast and differs by supplier and region, so consult recent sources like the IEA Global Hydrogen Review before trusting one figure.

Method & assumptions

Yearly production in kg = MW × 8,760 × CF × 1,000 ÷ specific energy use (kWh/kg). Stack degradation (%/1,000 h) makes that specific use rise until each replacement resets it, so what is applied is the mean across a stack's life. For efficiency on an LHV basis, use 33.33 ÷ kWh/kg; water is kg × L/kg; oxygen is about 7.94 kg per kg H₂. To get LCOH, add annualised capex (CRF at your WACC), the annualised present value of stack replacements, fixed O&M, electricity, compression and water (and steam for SOEC), then divide by annual kg.

Frequently asked questions

Power demand for one kg of hydrogen?
Alkaline systems today take about 50–55 kWh/kg and PEM systems 52–58 kWh/kg. Solid oxide needs around 40 kWh/kg of electricity plus heat. The hard floor is 39.4 kWh/kg, fixed by hydrogen's higher heating value.
Water consumption of hydrogen production?
Chemistry alone calls for 8.9 litres per kg. Purification losses lift real plants to about 10–15 L/kg, and evaporative cooling to 20–30 L/kg or more. Even so, the water bill is usually just a few cents per kg.
Green hydrogen price per kg?
Most projects today deliver about 4–8 per kg (EUR or USD). For comparison, grey hydrogen from natural gas, absent any carbon price, is about 1–3 per kg. Power price and electrolyzer operating hours (capacity factor) dominate the difference.
Output of a 1 MW electrolyzer?
At full load, about 18–20 kg an hour, so 440–480 kg per day if it never stops. Running at a 50% capacity factor, that comes to around 80–85 tonnes per year.
What does LCOH mean?
Levelized cost of hydrogen: everything the plant costs across its life (capital, stack replacements, operation, electricity, water), divided by kilograms produced. Consider it hydrogen's counterpart to LCOE.
PEM or alkaline: which wins?
Neither across the board. Alkaline units are cheaper, proven, long-lived and slightly more efficient at steady load. PEM is more compact, reacts faster to fluctuating renewable supply and outputs hydrogen at higher pressure, though it relies on platinum-group metals. Where cheap high-temperature heat exists, SOEC is the efficiency leader.
Why is capacity factor such a big lever?
Electrolyzers are expensive. One that runs only in daylight (20–25% of the year) spreads its capital over very few kilograms, so LCOH may be twice that of a plant working 50–60% of the time on wind plus solar.

Sources & references

  1. IEA — Global Hydrogen Review 2024
  2. IRENA (2020). Green Hydrogen Cost Reduction: Scaling up Electrolysers to Meet the 1.5 °C Climate Goal
  3. Clean Hydrogen Partnership — Strategic Research and Innovation Agenda (electrolyser KPIs)
  4. US DOE Hydrogen and Fuel Cell Technologies Office — Hydrogen production via electrolysis

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.