Cost drivers
After space heating, hot water is usually the biggest slice of a home’s energy, around 15–20%. Three factors set the cost: the heat the hot water needs, how well the appliance converts fuel into it, and the heat a tank loses while waiting.
The tool begins with physics. Give it household size, per-person hot water use and the two temperatures. It works out the useful heat per day, adds pipe losses, then compares six setups:
- Electric storage tank: resistance element, close to 100% efficient, while the tank keeps leaking heat day and night (standby loss).
- Heat-pump water heater: pulls heat from room air into the tank, giving 2.5–3.5 kWh of heat for each kWh of electricity (its COP), standby included.
- Gas storage tank: burner at roughly 75–80% efficiency, plus constant flue and pilot losses.
- Gas tankless or combi: heats only when asked, at 85–95%, with no storage loss.
- Electric tankless: 99% efficient, nothing stored, but every kWh at the full electricity price.
- Solar thermal with electric backup: sun supplies a share (the solar fraction) and an element finishes the job in a larger tank.
Outputs for each: energy purchased, running cost, purchase price spread over a typical life, and CO₂.
Equations
Electric tank: E = (Q + standby) ÷ 0.98 Heat pump: E = (Q + standby) ÷ COP Gas tank: E = Q ÷ η + standby/pilot gas Tankless: E = Q ÷ η Solar thermal: E = (Q + 1.3 × standby) × (1 − solar fraction) ÷ 0.98
Annual total cost = E × price + installed cost ÷ lifetime
Default household calculated
Three people, 45 litres each at 55 °C, cold supply 12 °C, 10% pipe losses: 135 L a day, rise of 43 K.
135 × 4.186 × 43 ÷ 3,600 × 1.10 = 7.4 kWh useful heat daily, about 2,710 kWh yearly.
- Electric tank: standby adds 1.3 kWh/day, so 3,250 kWh a year are purchased, €812 at €0.25/kWh. About €121 of that is standby loss alone, and a 35-litre shower costs about €0.58.
- Heat-pump unit at COP 2.8: about 1,140 kWh, €284 yearly, which is €528 less than the tank.
- Lowest total cost goes to gas tankless/combi: about €408 a year (€308 gas plus €2,000 over 20 years). The heat pump follows at about €500.
- CO₂: heat pump about 0.4 t a year; electric tank 1.1 t, assuming a 350 g/kWh grid.
Reading the outputs
- Running cost is your present heater’s yearly fuel or power bill.
- Cheapest to run leaves out purchase price; lowest total cost adds it, spread over each technology’s typical life.
- Standby loss is what it costs to keep a tank warm when nobody draws water, often 10–20% of an electric tank’s bill.
- Instant heater power for a shower explains the 40–63 A supply upgrade often needed for electric tankless: a 9 L/min shower at 40 °C draws around 17–18 kW.
- Stacked bars show running and capital cost apart.
Comparison table
| Type of heater | Efficiency or COP | Service life | Remarks |
|---|---|---|---|
| Electric storage tank | 98% plus 0.8–2 kWh/day standby | 10–15 yrs | low price tag, high running bill |
| Heat-pump water heater | COP 2.5–3.5 | 10–15 yrs | wants a room above ~10 °C |
| Gas storage tank | 70–80%, less pilot and flue losses | 8–12 yrs | in the US scored as UEF ≈ 0.6–0.7 |
| Gas tankless / combi | 85–95% | 15–20 yrs | condensing versions get to 95% |
| Electric tankless | 99% | 15–20 yrs | 18–27 kW to serve a whole house |
| Solar thermal + backup | 45–80% solar fraction | 20–25 yrs | most expensive to install |
Saving ideas
- Lag the tank and the pipe nearest to it. On older tanks that can recover 0.3–0.5 kWh a day cheaply.
- Fit a shower head that lowers flow from 12 to 8 L/min and shower energy drops by a third.
- With a time-of-use tariff, heat during the night, and use the night-tariff option to see what it does.
- Hot water stores midday surplus well, so pair a heat-pump unit or immersion with solar PV (see the solar panel calculator).
- Where a heat pump already heats the house, have it make hot water as well, using the heat pump calculator.
Model limits
Efficiencies are fixed here. In reality a heat-pump water heater loses COP in a cold room, gains it in a warm one, and chills the room it occupies. Tank size, insulation and set-point drive standby loss, and household hot water use varies a lot. For a better figure than the defaults, put a plug-in meter on an electric heater or read the gas meter twice a week apart. Prices differ by country and installation difficulty, and financing and maintenance are excluded. Gas options presume a gas connection already exists, with no extra standing charge.
Method & assumptions
Useful heat per day is Q = V × 4.186 × (Tset − Tcold) ÷ 3600 kWh, with pipe losses added on top. What you actually buy depends on the technology. An electric tank takes (Q + standby) ÷ 0.98, and a heat pump (Q + standby) ÷ COP. A gas tank needs Q ÷ η plus standby or pilot gas, and a tankless unit Q ÷ η. For solar, it is (Q + 1.3 × standby) × (1 − solar fraction). Total annual cost = running cost + installed cost ÷ lifetime.
Frequently asked questions
What does an electric water heater cost to run each year?
Is a heat pump water heater a good investment?
Do tankless heaters cost less than tanks?
How much energy does heating water take?
What setting should a water heater thermostat have?
How much hot water does one person use daily?
Sources & references
Embed this calculator