Heating & gas calculator

Heat pump calculator: running cost, SCOP, sizing and savings

A month-by-month model of an air-source heat pump in your climate gives heat demand, COP across outdoor and flow temperatures, electricity use, savings in running cost over your present boiler, and CO₂ avoided.

Editable share link Branded PDF report Free · no sign-up

Results

At a seasonal COP of 3.39, running the heat pump would cost roughly 1,180 € a year, which is 445 € below what you pay for heating today. It remains the cheaper option while electricity costs under 3.9× your fuel price per kWh (currently 2.8×).
Heat pump running cost
€1,180
Yearly electricity draw: 4,214 kWh
Seasonal COP (SCOP)
3.39
space heating and hot water, with weather-compensated flow at 45 °C
Current heating cost
€1,625
16,253 kWh of fuel burned at 88% efficiency
Annual saving
€445
Heat demand
14,303kWh/yr
102 kWh/m²·yr incl. hot water
Design heat loss
5.5kW
at -9 °C outdoor
Heat pump size
5.5kW
suggested nominal output
Backup heater share
0%
2 kWh supplied by the immersion or backup heater
CO₂ saved per year
1.5t
1.47 t vs 2.97 t now
Break-even price ratio
3.86
electricity price divided by fuel price, per kWh
Simple payback
31 yr 5 mo
Heating degree days
2,418K·d (base 15.5 °C)
Berlin, Germany
Heat output against electricity input, by month
COP at each outdoor temperature
Annual running cost

Month by month

MonthMean °CHeat (kWh)Electricity (kWh)COPCost (€)
Jan0.62,5088363234
Feb1.42,1527003.07196
Mar4.81,8525343.46150
Apr9.61,0742614.1273
May14.25121184.3333
Jun17.5263663.9918
Jul19.6210553.8215
Aug19.2217573.8316
Sep15.1414974.2727
Oct101,0502524.1671
Nov5.21,7314923.52138
Dec1.82,3207453.11209
  • Climate used: Berlin, Germany (approximate 1991–2020 normals). Daily temperature swings are represented by ±3.5 K bins.
  • The COP model takes a share of the Carnot limit, with a 3 K approach at the condenser and 5 K at the evaporator, and subtracts a defrost penalty near 0 °C. Poorly commissioned systems tend to show field SPFs 0.2–0.5 under their lab ratings.
  • Hot water demand is set at about 1.6 kWh per person each day, with another 1 kWh/day lost from the cylinder.

Method behind the estimate

Quoting a heat pump’s electricity bill needs only demand, COP and a tariff, yet shortcuts usually go wrong: pairing a brochure SCOP with a typical-demand guess can miss by 30–50%. This tool derives both quantities from your climate and building instead. Here is the chain.

Demand. The building is reduced to a heat-loss coefficient H in W/K: floor area times a factor for insulation quality (3.0 W/m²K in an uninsulated pre-war house, 0.25 W/m²K in a passive house), or it is worked backwards from today’s fuel use and local heating degree days.

Weather. Every month’s mean temperature is split into eleven bins. Sixteen preset cities use 1991–2020 normals; anywhere else on Earth uses NASA satellite climatology. Bins matter because cold spells push COP down at the very moment load peaks.

Efficiency per bin. Flow temperature follows a weather-compensation curve. COP equals a share of the Carnot ceiling, reduced by a defrost penalty from −7 °C to +7 °C, the range in which the outdoor coil ices up.

Resistive backup, and hot water. If the unit, derated for the cold, cannot meet the load, a resistive backup heater (COP 1) supplies the difference. For hot water, 1.6 kWh per person per day plus cylinder losses is heated up to the storage temperature you choose.

What you see: electricity per month, a realistic SCOP, running cost, comparison with the fuel you use now and the CO₂ difference.

Formulas

Space heat per bin = H × (T_base − T_out) × hours COP(T_out) = η × T_cond / (T_cond − T_evap) T_cond = T_flow + 3 K, T_evap = T_out − 5 K (kelvin) T_flow(T_out) = 22 + (T_design,flow − 22) × (20 − T_out) / (20 − T_design) Electricity = Σ heat / COP + backup SCOP = Σ heat / Σ electricity Break-even price ratio = SCOP / η_boiler

The factor η is what a real machine achieves of the Carnot COP: 0.42 for basic or older designs, 0.47 for current mid-range, 0.52 for premium inverter models using R290. A standard unit at 7 °C outside and 35 °C flow reaches COP of about 4.1, dropping to about 2.2 at −7 °C and 55 °C, consistent with EN 14511 data sheets.

Berlin, 140 m²: a worked case

Picture a 140 m² Berlin house of average insulation (1.5 W/m²K), fitted with a standard-grade heat pump on 45 °C design flow with weather compensation, and three occupants. Its annual heat need is about 14,300 kWh including hot water (102 kWh/m²), set against roughly 2,400 heating degree days (15.5 °C base).

The pump consumes about 4,210 kWh of electricity, so SCOP is 3.39; January COP is near 3.0 and April’s exceeds 4. With a design heat loss of 5.5 kW at −9 °C, a 5.5 kW unit meets nearly all demand and the backup supplies a mere 2 kWh per year.

Operating at 0.28 €/kWh, that costs ≈ 1,180 € a year. Your present gas boiler, 88% efficient over the season, would burn 16,250 kWh of gas costing about 1,625 € at 0.10 €/kWh. That is about 445 € and 1.5 t of CO₂ saved each year: 1.47 t on a 350 g/kWh grid against 2.97 t for gas. It remains cheaper until electricity exceeds 3.86 times the gas price, and today the ratio is 2.8. Installed at 14,000 € without any grant, simple payback takes about 31 years; grants, heat-pump tariffs and giving up the gas connection change that picture most.

What to look at

  • SCOP is the key figure; adding 0.5 to it cuts electricity use by about 13–15%.
  • Design heat loss gives the power required on a typical coldest day. If you are quoted 12 kW for a 5 kW house, that is oversized.
  • Backup share above 3–5% means the unit is undersized or flow temperature too high.
  • Break-even ratio tells you how robust the saving is: with yours far below it, price changes will not wipe it out.
  • Monthly table: winter carries 60–70% of the yearly bill.

Typical performance

Installation Flow temp. Realistic SCOP Electricity (kWh) per 10,000 kWh of heat
Underfloor heating, new build 30–35 °C 3.8–4.5 2,200–2,600
Retrofit with enlarged radiators 40–45 °C 3.2–3.8 2,600–3,100
Conventional radiators 50–55 °C 2.7–3.2 3,100–3,700
High-temperature model, small radiators 60–65 °C 2.2–2.7 3,700–4,500
Ground source with underfloor 35 °C 4.2–5.0 2,000–2,400

Cutting the bill

Start with flow temperature. Weather compensation plus new radiators in place of the two or three smallest ones is usually the cheapest efficiency gain. Insulate before you buy: demand and unit size both shrink (insulation savings calculator). Cheaper night-time electricity under a heat-pump or time-of-use tariff can take 20–40% off the effective price. Add PV (see solar panels) to cover summer hot water and mild-weather heating. Skip deep night setbacks: they demand hot water in the pipes at breakfast.

Where it falls short

Climate enters monthly with a statistical spread, not hour by hour, so defrost losses on windy or humid sites may be underestimated. Insulation presets are mean values, and a proper survey may deviate by ±25%. COP is modelled for typical current units, so read the EN 14825 data sheet of any specific model. Internal gains sit within the 15.5 °C base temperature; window solar gain is not modelled. For a ground-source system, switch to the ground source heat pump calculator.

Method & assumptions

Start with the building: its space heating is H (heat-loss coefficient, W/K) times the heating degree-hours falling under the base temperature. H comes from floor area times an insulation-based W/m²K value, or from your actual fuel use and local degree days. Every month is cut into eleven temperature bins (normal distribution, σ = 3.5 K), giving the cold snaps, where COP is poorest, their true weight.

Then the heat pump. In each bin a weather-compensation curve fixes the flow temperature (design flow at the design outdoor temperature, easing towards 25 °C in mild weather), and COP = η × Tcond / (Tcond − Tevap), where η is 0.42–0.52 of Carnot depending on quality. A direct-electric backup heater makes up any shortfall in capacity at that temperature. Seasonal figure: SCOP = total heat ÷ total electricity.

Frequently asked questions

What will a heat pump add to my yearly energy bill?
Work it out in three steps: take the heat your home needs in a year, divide by the seasonal COP, and price the resulting kWh. A European house requiring 12,000–15,000 kWh of heat and achieving SCOP 3–3.5 consumes 3,500–5,000 kWh of power. At 0.28 €/kWh that is roughly 1,000–1,500 €/yr. Tight insulation plus underfloor heating can bring it under 600 €/yr.
Which SCOP figure counts as good for air-source models?
Brochures claim SCOP 4–5, but that is measured at 35 °C flow in the EN 14825 lab procedure. Monitored homes tend to report seasonal performance factors of 2.8–3.5 instead. Reaching beyond 3.5 is excellent and normally needs flow temperatures of 35–45 °C together with weather compensation.
Do heat pumps beat gas boilers on cost per kWh of heat?
That hinges on how electricity is priced relative to gas. Pair SCOP 3.2 with a 90% boiler and the two cost the same when a kWh of electricity is about 3.5× a kWh of gas. Pay less than that multiple and the heat pump is cheaper. Your own break-even ratio appears in the results.
How do I pick the heat pump's capacity?
Start from the house's heat loss on the design day at your location. A modern 120–150 m² home typically ends up at 4–6 kW, an older uninsulated one at 8–14 kW. Buying too big wastes money and makes the machine switch on and off constantly, so commission a room-by-room heat-loss calculation (EN 12831 or MCS) first.
Is a heat pump still useful in a deep freeze?
Yes, with a lower COP. Modern air-source units still output heat at −20 °C or −25 °C; at −7 °C with 35–45 °C flow it typically falls to 2–2.5. Because so few days are that cold, the seasonal average stays well above it. Scandinavia, Europe's coldest region, has the highest uptake.
Why does a lower flow temperature help so much?
Heat from outdoor air must be pushed up to the flow temperature by the compressor, and every degree of that climb removed adds about 2–3% efficiency. Moving from 55 °C to 45 °C typically lifts SCOP 10–15%, which is the argument for bigger radiators or underfloor pipes.

Sources & references

  1. Commission Regulation (EU) No 813/2013 — ecodesign requirements for space heaters (seasonal efficiency per EN 14825)
  2. IEA — The Future of Heat Pumps (2022)
  3. UK DESNZ — Electrification of Heat Demonstration Project: final report
  4. NASA POWER — climatology API (monthly long-term temperatures)
  5. UK DESNZ — Greenhouse gas reporting: conversion factors 2024

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.