From a year of data to two numbers
A year on an anemometer logger leaves tens of thousands of 10-minute values. Sorting them by speed band gives a frequency distribution, the working tool for comparing sites and designing turbines. The Weibull distribution reproduces that histogram closely with only a shape factor k and a scale factor c.
Whichever inputs you have will do:
- mean speed and k, as when you read them off the Global Wind Atlas;
- mean and standard deviation from a logger summary, with k solved exactly from σ/v̄;
- k and c straight from an atlas or fitting report.
The page returns probability density and cumulative curves, hours and energy share per speed bin, and the hours a turbine with your cut-in, rated and cut-out speeds would operate.
Equations
mean v̄ = c × Γ(1 + 1/k) σ = c × √(Γ(1 + 2/k) − Γ(1 + 1/k)²) median = c × (ln 2)^(1/k) mode = c × ((k − 1) / k)^(1/k) speed carrying max. energy = c × ((k + 2) / k)^(1/k) hours in bin [a, b] = 8,760 × (F(b) − F(a))
Sample run: mean 6.5 m/s, k = 2
Defaults produce:
- c = 6.5 / Γ(1.5) = 7.33 m/s; standard deviation 3.40 m/s
- median 6.11 m/s; most probable speed 5.19 m/s
- peak-energy speed 10.4 m/s, well over the mean
- energy pattern factor 1.91
Now give the turbine a 3 m/s cut-in, 11.5 m/s rated speed and 25 m/s cut-out. Wind falls in the working range for about 7,400 hours a year (85%); about 750 hours exceed rated speed and about 1,350 fall under cut-in. Above cut-out the count is well under an hour. Choosing mean + standard deviation with 3.4 m/s returns k = 2.00 from the exact solution and 2.02 from Justus, so in the usual range the methods agree well.
What the charts tell you
- pdf: height of the curve = how common a speed is; its summit is the most probable speed.
- cdf gives the fraction of time below a speed, for instance the share of calm hours under cut-in.
- Hours per bin: bars are hours and the line is each bin’s slice of the wind’s energy. The two peaks lie far apart, because time clusters at moderate speeds and energy at high ones.
- Operating and rated hours feed maintenance planning and show how often a turbine will run clipped at full power.
Typical climates
| Climate | Typical k | Mean speed | Character |
|---|---|---|---|
| Sheltered inland, valleys | 1.3–1.7 | 3–5 m/s | many calms, occasional strong winds |
| Continental plains | 1.8–2.2 | 6–8 m/s | close to Rayleigh |
| Western European coasts | 2.0–2.3 | 7–9 m/s | frequent fronts |
| North Sea, offshore | 2.1–2.4 | 9–10.5 m/s | strong and fairly steady |
| Trade-wind islands | 2.8–3.5 | 7–9 m/s | very steady |
Practical pointers
- Mind the averaging period. Hourly means give a slightly higher k than 10-minute data, since averaging smooths short bursts.
- k varies with height, usually rising slightly up to around 50–100 m and falling above. Use parameters for your own height, and obtain the mean from the wind speed at height calculator.
- Use k as a sanity check. At an ordinary site, a fitted k below 1.3 or above 4 frequently points to sensor faults or icing.
- Then estimate energy. Mean and k go into the wind turbine calculator in manual mode, or into the wind power density calculator.
What a fit cannot promise
Weibull describes data; it is no law of nature. A site with two regimes (sea breeze plus synoptic storms, monsoon plus dry season) may be bimodal, and one curve then puts energy in the wrong bins. At very calm sites the curve can underestimate the hours with no wind at all. The moment method behind the mean + σ mode is dependable, yet in the high-speed tail it trails maximum-likelihood fitting and WAsP energy matching slightly. Whenever your own data exist, overlay the curve on its histogram.
Method & assumptions
Two curves describe the distribution. The pdf is f(v) = (k/c)(v/c)^(k−1) e^{−(v/c)^k} and the cdf is F(v) = 1 − e^{−(v/c)^k}. Its summary values: median c(ln 2)^{1/k}, mode c((k−1)/k)^{1/k}, and maximum-energy speed c((k+2)/k)^{1/k}. The mean is c·Γ(1+1/k) and σ = c·√(Γ(1+2/k) − Γ(1+1/k)²). If you supply mean and σ instead, bisection solves k from the ratio σ/v̄, while the Justus 1978 approximation, k ≈ (σ/v̄)^−1.086, appears alongside for comparison. For any bin from a to b, the hours are 8,760 × [F(b) − F(a)].
Frequently asked questions
What role does the Weibull distribution play in wind energy?
Can k and c be calculated from measured wind speeds?
Which k values are normal?
Rayleigh distribution: what is it?
Why does the energy pattern factor matter?
How many hours does a turbine actually run?
Sources & references
- Justus, C.G., Hargraves, W.R., Mikhail, A., Graber, D. (1978). Methods for estimating wind speed frequency distributions. Journal of Applied Meteorology 17(3)
- Troen, I. & Petersen, E.L. (1989). European Wind Atlas. Risø National Laboratory (WAsP Weibull fitting)
- IEC 61400-12-1: Power performance measurements — AEP for Rayleigh distributions
- Global Wind Atlas — Weibull k and A parameters for any location
Embed this calculator
Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.