The trouble with mean speed
Wind power scales with speed cubed: twice the speed, eight times the power. A gusty site and a steady one can share a mean speed and still differ widely in energy. Wind power density (WPD) removes the ambiguity. It averages v³ over the whole speed distribution and multiplies by half the air density.
Inputs are your mean speed and shape factor k; if you lack one, k = 2 (Rayleigh) is the fallback. The wind is modelled as a Weibull distribution. Air density comes from elevation and temperature, and the page then reports exact power density, NREL class, energy pattern factor and the speeds that carry the energy. Its chart contrasts time with energy: hours pile up at moderate speeds, whereas much of the energy comes from less frequent strong winds.
Equations
c = v̄ / Γ(1 + 1/k) (Weibull scale) EPF = Γ(1 + 3/k) / Γ(1 + 1/k)³ (energy pattern factor) WPD = EPF × ½ × ρ × v̄³ ρ = p / (287.05 × T), p = 101,325 × (1 − 2.2558×10⁻⁵ × z)^5.2559
Here Γ is the gamma function, p is pressure at altitude z (m) and T is absolute temperature (K). EPF equals 1.91 for k = 2, rises to 2.7 for gusty inland wind (k = 1.5) and falls to 1.4 for steady trade winds (k = 3).
Walk-through at 7 m/s
Start from a mean of 7.0 m/s at 50 m, k = 2, elevation 200 m and a 10 °C annual mean temperature. Density at that height is about 1.21 kg/m³, 1% below standard.
- c = 7.0 / Γ(1.5) = 7.90 m/s.
- WPD = ½ × 1.21 × 7.90³ × Γ(2.5) ≈ 397 W/m².
- Compare the shortcut ½ρv̄³ = 208 W/m², which misses by almost 50%.
397 W/m² at 50 m is NREL class 3 (“fair”), a little short of class 4. The modal speed is only 5.6 m/s, yet the speed carrying the most energy is 11.2 m/s, and almost half of all energy comes from winds at or above 12 m/s. At those speeds a turbine already runs at rated power and spills the surplus. This is why large rotors on modest generators capture more of a site’s energy.
Using each result
- Wind power density is the main output. Times 8.76 it gives kWh per m² of swept area per year.
- NREL class: power density is converted to 50 m with the 1/7 power law, so data from any height can be matched to the table.
- Energy pattern factor tells you how far the speed distribution lifts power above the mean-speed estimate.
- Most energetic speed guides design, as rated speed usually sits at 1.1–1.4× this value.
- IEC turbine class goes from I (high wind, 10 m/s mean) to IV (6 m/s), using mean speed extrapolated to 100 m.
NREL classes
| NREL class | Rating | WPD at 50 m (W/m²) | Speed at 50 m (m/s) |
|---|---|---|---|
| 1 | Poor | 0–200 | 0–5.6 |
| 2 | Marginal | 200–300 | 5.6–6.4 |
| 3 | Fair | 300–400 | 6.4–7.0 |
| 4 | Good | 400–500 | 7.0–7.5 |
| 5 | Excellent | 500–600 | 7.5–8.0 |
| 6 | Outstanding | 600–800 | 8.0–8.8 |
| 7 | Superb | > 800 | > 8.8 |
The speeds above presume sea-level density and k = 2. In practice, at 100 m: inland Europe 250–450 W/m², windy coasts and plains 450–800 W/m², North Sea 800–1,000 W/m², Patagonia or exposed islands above 1,000 W/m².
Practical notes
- Get k right. Replacing 2.0 with 1.6 lifts the result by 30% at the same mean speed. Fit it from measurements in the Weibull calculator.
- Compare like with like. Convert sites measured at different heights using the wind speed at height calculator.
- Correct for elevation. Thin air takes 10–25% of the power at mountain and plateau sites, which affects small-turbine payback.
- WPD is not yield. Betz limits what a rotor can take; the wind turbine calculator converts it to kWh.
Limits
Weibull does not always fit. Sea-breeze and monsoon regimes can be bimodal, and very calm sites record more zero-wind hours than the model predicts. Density uses annual mean temperature; in Europe cold air often coincides with strong wind, which lifts real power density a few percent. NREL classes assume a 1/7 power law, which your terrain may not follow. Before investing, compute power density directly from at least a year of measured 10-minute data.
Method & assumptions
Take a Weibull regime. Its power density is WPD = ½ ρ c³ Γ(1 + 3/k) once the scale is set as c = v̄ / Γ(1 + 1/k). This is identical to ½ ρ v̄³ × EPF, where the energy pattern factor is EPF = Γ(1+3/k)/Γ(1+1/k)³, giving 1.91 for k = 2. To get density, the barometric formula supplies p at elevation + height, temperature lapses at 6.5 °C/km, and ρ = p / (287.05 T). Matching the NREL table needs the 10 m and 50 m values, reached via the power law (WPD ∝ h^{3α}).
Frequently asked questions
Wind power density: what is it?
Which wind power density figures are worth building on?
Is ½ρv³ with mean speed good enough?
How do altitude and temperature change it?
How much of the wind's power ends up as electricity?
Where do the NREL wind classes come from?
Sources & references
- Elliott, D.L. et al. (1986). Wind Energy Resource Atlas of the United States. DOE/CH 10093-4, Pacific Northwest Laboratory
- Global Wind Atlas (DTU / World Bank) — mean power density maps
- Manwell, J.F., McGowan, J.G., Rogers, A.L. — Wind Energy Explained, 2nd ed., Wiley
- Justus, C.G., Hargraves, W.R., Mikhail, A., Graber, D. (1978). Methods for estimating wind speed frequency distributions. Journal of Applied Meteorology 17
Embed this calculator
Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.