Calorific value (HHV / LHV)

Heat given off when a fixed amount of fuel burns completely; the higher (gross) value counts the condensation heat of water vapour, the lower (net) value leaves it out.

Burning a fuel produces water, and whether that water's latent heat is credited splits heating values into two kinds. The gross figure, written HHV (also the higher or gross calorific value), applies when the exhaust is chilled to 25 °C and the water condenses, handing back about 2.44 MJ for every kg of it. The net figure, written LHV (the lower or net calorific value), applies when the water leaves as vapour, so the latent heat is simply lost to the chimney and not counted. In everyday speech either number may be called the calorific value, or just the heating value of the fuel.

HHV = LHV + m_water x h_fg (h_fg ≈ 2.44 MJ/kg at 25 °C)
LHV/HHV ratios: hydrogen 0.85 (120 / 141.8 MJ/kg); natural gas about 0.90 (50 / 55.5 MJ/kg methane); diesel/gasoline about 0.93–0.94; coal 0.95–0.97
Wood at 20% moisture: LHV about 14–15 MJ/kg; dry wood about 18–19 MJ/kg

Which basis you meet depends on where and in which sector you look. Statistics from Europe, and the efficiency ratings of engines and turbines, are normally quoted on LHV, while American statistics (EIA) and gas bills use HHV. That is why a condensing boiler can be marketed at "107% efficient" using LHV when the same appliance rates about 97% by HHV, and why a combined-cycle plant rated at 60% LHV is about 54% by HHV. Hydrogen is the most sensitive case, because electrolyser efficiency given per HHV reads about 18% higher than per LHV.

Wet fuels such as biomass and lignite lose a large share of their net heating value to moisture. Quantities of any fuel can be turned into energy with the fuel energy content calculator.

Related terms

All terms →
  • Energy density

    Specific energy, in MJ/kg or Wh/kg when counted per mass, and in MJ/L or Wh/L when counted per volume: how much energy a fuel or storage medium holds.

  • Heat rate

    Fuel energy a thermal plant has to burn per kWh of electricity delivered; it is efficiency turned upside down, typically stated in BTU/kWh or kJ/kWh.

  • Natural gas

    A fossil fuel made up mostly of methane, burned for electricity and for industrial and home heat, and used as a feedstock for hydrogen and ammonia.

  • Green hydrogen

    Hydrogen from water split in an electrolyser that runs on renewable power, so little CO2 is emitted directly.

  • Tonne of oil equivalent (toe)

    A standard energy unit, 41.868 GJ (10 Gcal, 11.63 MWh), set as the nominal heat content of a tonne of crude oil and applied in energy balances.

  • BTU (British thermal unit)

    Historic heat measure: roughly what it takes to warm 1 lb of water by 1 °F. Exactly, 1 BTU (IT) is 1,055.06 J.