Glossary · Grid & markets

Curtailment

Output that a wind or solar plant could have delivered but is ordered, or elects, not to, owing to network limits, market conditions or system-security needs.

A plant that is able to run but is told, or decides, to hold back is being curtailed. With wind and solar the lost energy would have had zero marginal cost. Causes fall into three groups:

  • Network congestion: the lines cannot move the power to where it is used (typical of northern Germany, west Texas and Inner Mongolia).
  • System security: operators need enough synchronous plant online to supply inertia, voltage control or reserves.
  • Market economics: when prices go below zero, unsubsidised generators back off (see negative prices).
Curtailment rate = Curtailed energy / (Generated + Curtailed energy)

Examples: Germany lost about 3 to 4% of renewable output to curtailment in recent years, and redispatch plus compensation exceeded EUR 3 billion annually (Bundesnetzagentur). CAISO in California curtailed about 3.4 TWh of wind and solar in 2023, mainly in spring around midday. China cut wind curtailment from about 17% in 2016 to roughly 3 to 4% by adding UHV transmission.

Zero curtailment is not the economic goal: a grid or storage fleet sized to absorb every kWh would cost more than the energy it saves. NREL and IEA studies commonly put the optimum at a few percent when VRE shares are high. Ways to reduce it include HVDC links, storage, flexible demand, electrolysers and improved market design.

Related terms

All terms →
  • Variable renewable energy (VRE)

    Wind and solar PV power, whose production rises and falls with weather and daylight and cannot be fully scheduled by the operator.

  • Negative electricity prices

    Wholesale electricity priced under zero: generators pay to feed in because supply that cannot ramp down exceeds demand.

  • Interconnector

    Transmission line, AC or HVDC, between the grids of different countries, regions or market zones, letting them trade power.

  • HVDC (High-Voltage Direct Current)

    Bulk power transmission using direct current, which loses less energy over long distances and can join grids that are not synchronised.

  • Duck curve

    A pattern in grids with much solar: net load sags deeply at midday when PV output peaks, then ramps up sharply as evening approaches.

  • Inverter clipping

    Energy lost when a PV array can produce more DC power than the inverter's AC rating, so the inverter limits output to its maximum.