Glossary · Solar

Inverter clipping

Energy lost when a PV array can produce more DC power than the inverter's AC rating, so the inverter limits output to its maximum.

Oversizing the array relative to the inverter is standard practice (see DC/AC ratio). In hours with strong sun and cool modules, the array can then supply more than the inverter is able to convert. The inverter shifts the array away from its maximum power point to hold input down, and the output curve gets a flat top around midday. The energy cut off is the clipped energy.

Eclipped = Σ max(0, PDC,avail(t) × ηinv − PAC,max) · Δt

How much is lost depends on the DC/AC ratio, climate, orientation and tracking:

  • Fixed-tilt systems in central Europe at DC/AC 1.1–1.2: normally below 1% of yearly energy.
  • Single-axis trackers in sunny climates at DC/AC 1.3: about 1–4%.
  • DC/AC of 1.5 or more: 5–10% or higher; worthwhile only with very cheap modules or limited grid capacity.

Good estimates need hourly or, better, sub-hourly simulation. Hourly averages flatten brief irradiance peaks and so understate clipping. On cold, clear days with cloud-edge enhancement, momentary DC power can even exceed the module's STC rating.

The clipped energy need not be lost. A DC-coupled battery can capture it ahead of the inverter, which is a strong reason to choose DC coupling in hybrid PV-plus-BESS plants. Do not confuse clipping with grid curtailment, where the system operator imposes the limit from outside.

Related terms

All terms →
  • DC/AC ratio

    The inverter loading ratio (ILR): the array's STC nameplate DC capacity relative to the inverter's AC rating.

  • String inverter

    A PV inverter that takes the DC from one or several module strings in series and delivers AC in step with the grid. It usually has multiple MPPT inputs that work independently.

  • Curtailment

    Output that a wind or solar plant could have delivered but is ordered, or elects, not to, owing to network limits, market conditions or system-security needs.

  • BESS (Battery Energy Storage System)

    A full grid-connected or on-site battery plant: cells, battery management, power electronics, thermal management and control systems.

  • Performance ratio

    Actual AC energy delivered divided by the theoretical output given plane-of-array irradiation and nameplate capacity; a quality measure for PV plants that does not depend on location.