Cycle life
Number of complete charge and discharge rounds a battery completes before retaining only a set fraction, commonly 70–80%, of its rated capacity.
A cycle-life rating is only meaningful with its test conditions attached: depth of discharge, C-rate, temperature and the end-of-life threshold. A cell specified at 6,000 cycles for 0.5C, 25 °C and 80% DoD can fall well short when run at 1C and 40 °C.
Example: 6,000 x 0.9 x 10 kWh x 0.9 ≈ 48.6 MWh
Typical figures until capacity reaches 80%:
- Lead-acid (50% DoD): 500–1,500
- NMC: 1,000–2,500
- LFP: 4,000–8,000 or more
- Lithium titanate (LTO): 10,000–20,000
- Vanadium flow battery: over 15,000, with an electrolyte that can be reused almost without limit
Separately, batteries age simply by existing, faster when hot or kept at a high state of charge. Cycling a home battery once a day uses 365 cycles a year, so 6,000 cycles take about 16 years and the calendar life (often warranted at 10–15 years) usually runs out first. Cycle life feeds directly into LCOS.
Related terms
All terms →- Depth of discharge (DoD)
Percentage of a battery's capacity already drawn out; also the ceiling on that percentage which the manufacturer permits per cycle.
- C-rate
Battery charge or discharge current expressed against capacity: at 1C a full battery empties in an hour, at 0.5C in two.
- LFP (Lithium Iron Phosphate)
Lithium-ion cathode chemistry (LiFePO4) valued for safety, long life and low cost, though its energy density is below that of nickel-based cells.
- NMC (Nickel Manganese Cobalt)
Lithium-ion cathode chemistry (LiNixMnyCozO2) prized for energy density, found in many long-range electric cars.
- LCOS (Levelized Cost of Storage)
Lifetime average cost for each MWh a storage asset discharges, covering investment, operation, charging electricity and efficiency losses.
- State of charge (SoC)
The charge left in a battery, shown as a percentage of its present full capacity.