Glossary · Geothermal

Enhanced geothermal system (EGS)

A geothermal reservoir engineered in hot rock of low permeability, usually through hydraulic fracturing or shearing, so that water pumped between wells can carry the heat out.

Normal geothermal power needs heat, fluid and natural permeability in the same place. EGS builds the reservoir artificially and so drops the need for the last two, which could in principle allow hot dry rock to be tapped almost anywhere that is deep enough.

The procedure starts with an injection well drilled into rock at roughly 150–250°C, usually 3–6 km down depending on the geothermal gradient. High-pressure water then opens fractures, and one or more production wells are drilled into the fractured volume. Cold water goes in, warms up as it crosses the rock, comes out at the surface to drive a binary or flash plant, and is sent back down in a closed loop.

A well pair's thermal output follows from:

Qth = ṁ cp (Tprod − Tinj)

For example, 60 kg/s cooled from 190°C to 70°C yields about 30 MW thermal, or roughly 3–5 MW electric.

Reference projects: Soultz-sous-Forêts in France (about 1.7 MW since 2016) and the US DOE FORGE field laboratory in Utah. At Project Red in Nevada (2023), Fervo Energy borrowed horizontal drilling and multi-stage stimulation from shale oil and reported about 3.5 MW per well at around 60 kg/s; its Cape Station in Utah aims for 500 MW. NREL ATB and DOE see a large potential, with the US EGS resource put at hundreds of GW, provided drilling gets cheaper. Principal risks are cost, flow paths short-circuiting between wells, and induced seismicity: the Basel (2006) and Pohang (2017) projects were stopped after earthquakes were felt.

Related terms

All terms →
  • Geothermal gradient

    Away from plate boundaries, rock gets hotter by roughly 25 to 30 °C with every kilometre of depth; this is the geothermal gradient.

  • Binary cycle power plant

    Geothermal plant type where hot brine warms a second fluid with a low boiling point, which spins the turbine; makes power possible from sources of about 100 to 180 °C.

  • Capacity factor

    Actual energy a power plant generates in a period divided by what it would generate at full nameplate capacity throughout that period.

  • Baseload

    Lowest electricity demand seen on a grid across a day, season or year, historically met by plants running nonstop at high output.

  • Dispatchable generation

    Generation that the operator can schedule, ramp up or turn down on demand, whatever the weather.