Glossary · Grid & markets

Frequency containment reserve (FCR)

Europe's quickest automatic balancing reserve, which reacts within seconds so that a frequency deviation stops growing.

Each unit that senses the frequency activates FCR locally; older terminology calls it primary reserve. Continental Europe procures about 3,000 MW of FCR, enough to cover the simultaneous loss of two large nuclear units, and it must be fully active within 30 seconds for a 200 mHz deviation. In Germany and Britain, batteries now provide much of it.

FCR halts the decline but does not reverse it; slower frequency restoration reserves then return the frequency to 50 Hz. The North American counterpart is called primary frequency response.

Related terms

All terms →
  • Frequency restoration reserve (aFRR, mFRR)

    Balancing reserves that bring grid frequency back to its nominal value and free up the fast reserves; they are activated automatically (aFRR) or by hand (mFRR).

  • Frequency response

    The automatic shift in generation or demand that halts and then corrects a frequency drift following a sudden mismatch on the grid.

  • Grid frequency

    How many times per second alternating current reverses on a power system, 50 Hz or 60 Hz; it mirrors the moment-to-moment balance between supply and demand.

  • Ancillary services

    Products other than bulk energy that grid operators buy to keep the system stable and secure: frequency reserves, voltage support, black start and the like.