Glossary · Hydro & ocean

Francis turbine

A reaction hydro turbine with fixed blades, where water flows in radially and out axially; the most installed design, suited to medium heads of about 30 to 700 m.

The Francis turbine, created by James B. Francis at Lowell, Massachusetts, around 1848, belongs to the reaction family: its runner runs fully flooded and pressurised, and the water hands over energy through both a pressure fall and a change of velocity. A spiral casing (volute) feeds the water to adjustable wicket gates, which set flow and swirl; after passing the runner it exits into a draft tube that regains kinetic energy.

Key figures:

  • Head range: roughly 30–700 m, though the bulk of units work at 40–400 m (hydraulic head)
  • Peak efficiency: 93–96% for big machines; below roughly 40–50% of rated flow it drops sharply, as vortex rope and pressure pulsations form in the draft tube
  • Unit size: from below 1 MW to 1,000 MW; Baihetan in China has 16 Francis units of 1,000 MW each, whereas Three Gorges and Itaipu have 700 MW-class units

Because large reservoir dams typically offer medium head, Francis machines account for most hydro capacity installed around the world. The reversible Francis pump-turbine is the standard choice for pumped hydro storage: it pumps when turning one way and generates when turning the other.

Design problems include cavitation, which is controlled by positioning the runner under the tailwater level, and unstable running at part load, an issue that matters more now that hydro stations help to balance variable wind and solar output.

Related terms

All terms →
  • Hydraulic head

    Vertical distance from the water level at a hydropower intake down to the turbine outlet (tailwater); multiplied with flow, it fixes the power on offer.

  • Pelton turbine

    An impulse turbine for hydro power: fast jets of water hit double-cupped buckets around a wheel. It is the standard pick when the head is above roughly 250 m.

  • Kaplan turbine

    Propeller-type reaction turbine for hydro plants; both its runner blades and its wicket gates can be adjusted, so it suits low heads (about 2 to 40 m) and high flows.

  • Pumped hydro storage

    A storage method that pumps water uphill to a reservoir when electricity is cheap or plentiful and sends it back through turbines when demand rises; worldwide, it is the biggest type of grid storage.

  • Run-of-river hydro

    Hydro generation that takes water from a river's natural flow with hardly any reservoir, so output rises and falls with the river and not with demand.