Pressurised water reactor (PWR)
The most widespread type of nuclear reactor: high-pressure water keeps the core cool without boiling and passes its heat to a separate steam circuit.
Inside a PWR, the primary loop runs at about 155 bar. That pressure keeps water liquid although it leaves the core at 315–330°C. A pressuriser holds the pressure steady, and coolant pumps drive the water through steam generators. There, heat moves into a separate secondary loop, where steam at around 60–70 bar spins the turbine. The radioactive water of the primary loop stays out of the turbine hall.
Roughly 70% of the reactors operating in the world, and of installed nuclear capacity, are PWRs; the Russian VVER is a member of the family. Fuel pellets of uranium dioxide, enriched to 3–5% U-235, are stacked in zircaloy-clad rods bundled into assemblies. A refuelling outage every 12–24 months swaps out about a third of the core. The same water cools and moderates, and this yields a negative void coefficient: should water boil off or leak away, reactivity falls. That is a major inherent safety feature.
Newer Generation III+ examples: the Westinghouse AP1000 (72 hours of passive cooling without operator action; Vogtle 3 and 4 in the US, Sanmen and Haiyang in China), the EPR (1,600–1,650 MWe; Taishan, Olkiluoto 3, Flamanville 3, Hinkley Point C), the Korean APR-1400, China's Hualong One and Russia's VVER-1200. Typical capacity factors range from 80 to 93%. Most light-water SMRs are compact integral PWRs.
Related terms
All terms →- Boiling water reactor (BWR)
Light-water nuclear reactor whose coolant boils inside the core, sending the steam straight to the turbine with no steam generators.
- Nuclear fission
A heavy nucleus, such as uranium-235 or plutonium-239, absorbs a neutron and breaks into lighter nuclei, giving off about 200 MeV and more neutrons.
- Uranium enrichment
Lifting the fraction of fissile U-235 in uranium from the natural 0.711% to a level suitable for reactor fuel, or at the extreme end, for weapons.
- SMR (Small Modular Reactor)
A nuclear reactor of up to roughly 300 MWe per module, built in a factory and deployed in modules to shorten construction and reduce financing risk.
- Burnup
Thermal energy taken out of nuclear fuel for each unit of initial heavy-metal mass, typically given as gigawatt-days per tonne (GWd/tHM).
- Capacity uprate
A permitted boost to the maximum output of a power plant already in operation, usually a nuclear reactor, using improved measurement or new equipment.