Glossary · Grid & markets

Transmission and distribution losses

Energy lost between generation and customers, partly as heat and partly from non-technical causes such as theft. It is generally stated as a share of energy supplied.

Not every kilowatt-hour sent into the grid reaches a paying customer. Transmission and distribution (T&D) losses are that shortfall. Technical losses come mostly from conductors and transformers warming up under load. Non-technical losses are theft, faulty meters and power that is used but never invoiced.

Ploss = I² × R = (P / V)² × R

The formula shows why voltage matters: heat loss rises with current squared. Carry the same power at twice the voltage and resistive loss falls by about 75%. Grid designers act on this. Long-haul lines run at 220–765 kV AC or as HVDC, and local networks step down to 0.4–110 kV.

Total losses by country (World Bank and IEA data):

  • About 3–5% in Germany, the Netherlands, Japan and South Korea.
  • The US sits near 5% (EIA), and the world average is roughly 8%.
  • India lost 15–20% including non-technical causes, an improvement on the 25%-plus of the 2000s.
  • Parts of sub-Saharan Africa and Iraq lose more than 20–30%.

High-voltage transmission is responsible for a third or less of the technical total. The bulk is dissipated in distribution transformers and low-voltage feeders. Utilities cut it with higher operating voltages, amorphous-core transformers, high-temperature low-sag conductors that replace old wire, reactive power compensation (which lifts power factor), smart meters, and local generation near demand.

Related terms

All terms →
  • HVDC (High-Voltage Direct Current)

    Bulk power transmission using direct current, which loses less energy over long distances and can join grids that are not synchronised.

  • Interconnector

    Transmission line, AC or HVDC, between the grids of different countries, regions or market zones, letting them trade power.

  • Reactive power

    Power that cycles between supply and load with no net work done. Magnetic and electric fields depend on it, and so does voltage control.

  • Power factor

    In an AC circuit, active power divided by apparent power: a number from 0 to 1 that shows how well the current does useful work.

  • Smart meter

    A meter that logs usage electronically at short intervals and sends the readings remotely to the supplier and the network operator.

  • Final energy

    The part of energy that arrives at end users (homes, factories, vehicles, services) as electricity, fuels or district heat once conversion and delivery losses are over.