Glossary · Grid & markets

Power factor

In an AC circuit, active power divided by apparent power: a number from 0 to 1 that shows how well the current does useful work.

Only part of the current in an AC circuit produces real work. Power factor (PF) expresses that part. PF of 1 means voltage and current rise and fall together. Anything lower shows that some current is busy with reactive power or harmonic distortion.

PF = P / S = P / (Vrms × Irms) (= cos φ for sinusoidal waveforms)

Inductive equipment, namely induction motors, transformers and magnetic ballasts, has a lagging power factor, and lightly loaded motors commonly sit at 0.7 to 0.85. Capacitive equipment gives a leading one. Rectifiers, cheap LED drivers and variable-speed drives are non-linear: they distort the current and cut true power factor even when the displacement angle is small.

The cost of low power factor is extra current for the same useful power. Cables, transformers and generators must be bigger, and resistive losses go up. Compare PF 0.8 with unity: current is 25% higher and I²R losses about 56% higher.

This is why commercial and industrial customers get charged. Utilities often penalise values under 0.90 to 0.95, or bill reactive energy in kvarh. Remedies: capacitor banks, active correction circuits in power supplies (driven by the harmonic limits of IEC 61000-3-2), synchronous motors, and inverters that inject reactive power. Under standards like IEEE 1547-2018 and EN 50549, solar inverters can operate at a fixed PF or follow volt-var curves.

Related terms

All terms →
  • Reactive power

    Power that cycles between supply and load with no net work done. Magnetic and electric fields depend on it, and so does voltage control.

  • Transmission and distribution losses

    Energy lost between generation and customers, partly as heat and partly from non-technical causes such as theft. It is generally stated as a share of energy supplied.

  • Ancillary services

    Products other than bulk energy that grid operators buy to keep the system stable and secure: frequency reserves, voltage support, black start and the like.

  • Smart meter

    A meter that logs usage electronically at short intervals and sends the readings remotely to the supplier and the network operator.

  • String inverter

    A PV inverter that takes the DC from one or several module strings in series and delivers AC in step with the grid. It usually has multiple MPPT inputs that work independently.

  • Watt (W)