Heating & gas calculator

Generator fuel use: litres per hour, runtime and cost per kWh

Discover how much fuel a generator uses at any load, whether diesel, petrol, LPG or natural gas, how long one tank lasts and what each kWh costs after counting engine wear, set beside grid power and solar with battery storage.

Editable share link Branded PDF report Free · no sign-up

Results

The generator burns 2.05 L/h, so a 50 L tank gives 24.4 h. Counting wear, a kWh costs 0.79 €: 3.1× what the grid charges and 4.4× what solar plus battery costs.
Fuel consumption
2.05L/h
5 kW output (50% load)
Runtime per tank
24.4hours
Energy per L
2.44kWh/L
fuel-to-electric efficiency 24%
Fuel cost per kWh
0.656€/kWh
Total cost per kWh
0.786€/kWh
fuel, maintenance and engine wear
Fuel per month
492L
240 running hours
Monthly running cost
€847
1,200 kWh generated
Same energy from grid
€300
Equivalent energy from solar plus battery
€216
CO₂ per kWh
1.1kg
1,319 kg per month
Fuel consumption and efficiency by load
Cost per kWh compared

Load table

LoadOutput (kW)Fuel (L/h)kWh/LFuel cost (€/kWh)Runtime per tank (h)
10%11.050.951.6847.6
20%21.31.541.0438.5
25%2.51.431.750.91235.1
30%31.551.940.82732.3
40%41.82.220.7227.8
50%52.052.440.65624.4
60%62.32.610.61321.7
70%72.552.750.58319.6
75%7.52.682.80.57118.7
80%82.82.860.5617.9
90%93.052.950.54216.4
100%103.33.030.52815.2
  • The fuel curve is F = a × P_rated + b × P_out, a linear model found in HOMER and most generator datasheets. Defaults fit typical small and medium sets. Type in the 25/50/75/100% points from your own datasheet for a closer match.
  • Inverter generators slow the engine down at light load, beating this curve by 20–40% under half load.

Straight-line fuel curve

Datasheets list fuel burn at 25%, 50%, 75% and 100% load. Plot those points and they fall nearly on a straight line that misses the origin. One term is a fixed idle burn tied to engine size; the other grows with the power you really draw. The same linear curve, used in HOMER and most hybrid-system design tools, drives this calculator for diesel, petrol, LPG and natural-gas sets.

From it you get hourly consumption at your average load, hours per tank, kWh per litre (or per m³ of gas), and what each kWh really costs. That price includes maintenance and engine wear, wear meaning the purchase price divided over the engine’s lifetime hours. Results are then set beside grid power and solar plus battery, with CO₂ per kWh.

Equations

Fuel flow F = a × P_rated + b × P_out (L/h or m³/h)

kWh per litre = P_out ÷ F Runtime per tank = tank ÷ F Electrical efficiency = P_out ÷ (F × fuel energy content)

Cost per kWh = fuel price ÷ (kWh per litre) + (purchase ÷ engine life hours + maintenance per hour) ÷ P_out

Coefficients per fuel: natural gas a = 0.10, b = 0.30 m³/kWh; LPG a = 0.15, b = 0.45 (litres of liquid); petrol a = 0.12, b = 0.33; diesel a = 0.08, b = 0.25 L/kWh. Energy content: natural gas 10.55 kWh/m³, LPG 7.08 kWh/L, petrol 9.1, diesel 10.0 kWh/L.

Example: 10 kW diesel set

Default scenario: 10 kW diesel, 50% load (5 kW), 8 h a day for 30 days, 50 L tank, diesel at €1.60/L.

Consumption is 0.08 × 10 + 0.25 × 5 = 2.05 L/h. Each litre gives 5 ÷ 2.05 = 2.44 kWh, so fuel-to-electric efficiency is about 24%, and a full tank covers roughly 24 hours. Fuel cost: 1.60 ÷ 2.44 = €0.66 per kWh.

Wear costs €6,000 ÷ 15,000 h = €0.40 per hour, plus €0.25 for maintenance. Spread across 5 kW, this adds €0.13/kWh and the all-in figure becomes €0.79/kWh. Across a month (240 running hours) the set uses 492 L, produces 1,200 kWh and costs about €847 in fuel and maintenance. For comparison, the same energy from the grid at €0.25/kWh costs €300, and from solar plus battery at €0.18/kWh €216. Emissions run to about 1.1 kg CO₂ per kWh, 1.3 tonnes a month.

Load makes a big difference. At 20% this machine yields only 1.54 kWh per litre (€1.04/kWh for fuel alone), whereas at full load it gives 3.03 kWh/L (€0.53/kWh).

Using the output

  • Fuel consumption: hourly litres or m³ at your mean load.
  • Energy per litre: the best sign of whether the set fits the load. A diesel under about 2 kWh/L is probably too big.
  • Total cost per kWh is the number to hold against grid and solar prices; fuel on its own understates it.
  • Chart: litres per hour climbs with load while kWh per litre dips at low load. The best zone is usually 60–85% load.
  • Verdict warns when load falls under 30%, the zone of wasted diesel and wet-stacking.

Reference table

Machine Load level Usual consumption Output per unit of fuel
3 kW portable, petrol 50% 0.8–1.0 L/h 1.5–2.0 kWh/L
2 kW inverter, petrol 25% 0.3–0.5 L/h 1.0–1.7 kWh/L
10 kW diesel set 50% 1.8–2.2 L/h 2.3–2.8 kWh/L
Diesel 10 kW 100% 3.0–3.5 L/h 2.9–3.3 kWh/L
100 kVA (80 kW) diesel set 75% 16–19 L/h 3.2–3.7 kWh/L
20 kW standby, natural gas 50% 3.5–4.5 m³/h 2.2–2.9 kWh/m³

Ways to burn less

  • Fit the set to the load. At 20% load a big generator may burn 50–60% more fuel per kWh than a smaller one at 70%.
  • Pair it with a battery. Charge it during a few hours of hard running, then stop the engine. Off-grid designers call this cycle charging. The solar battery calculator sizes the battery.
  • Add PV. Even a small array can cut running hours by 50–80% in sunny months; the solar panel calculator estimates its output.
  • Choose an inverter model for light duty. Its variable engine speed saves 20–40% under half load.
  • Service it. Clean filters, correct oil and sound injectors keep consumption near the datasheet.

Accuracy notes

A straight line only approximates real behaviour, so enter your datasheet’s coefficients for tighter results. Altitude, temperature, power factor and frequent load changes shift real consumption, and engine life and maintenance costs differ widely between consumer portables and industrial prime-power sets. Fuel price is held fixed, remote-site delivery is not counted, and CO₂ covers burning only, not fuel production.

Method & assumptions

Fuel use per hour (litres or m³) follows a × rated kW + b × output kW. Dividing output by (fuel flow × energy content) gives electrical efficiency. Each kWh costs fuel price ÷ kWh per unit, to which (purchase price ÷ engine life hours + maintenance per hour) ÷ output kW is added for wear. Emission factors assumed: diesel 2.68, petrol 2.31, LPG 1.51 kg CO₂ per litre; natural gas 1.93 kg per m³.

Frequently asked questions

What is the diesel burn of a generator per hour?
Plan on 0.25–0.27 L for each kWh delivered at medium to high load, with an extra idle draw near 0.08 L/h per kW of nameplate. A 10 kW diesel therefore draws roughly 2 L/h at half load and 3.3 L/h flat out. An 80 kW (100 kVA) machine consumes roughly 13–23 L/h, depending on how hard it works.
How many hours will a full tank last?
Tank volume divided by hourly consumption at your usual load gives the answer. Fill a 50 L tank on a 10 kW diesel and you get about 24 hours at half load, or about 15 at full load. Petrol portables with 10–25 L tanks typically last 6–12 hours at half load.
Why do lightly loaded generators waste so much fuel?
Friction, cooling and pumping losses do not shrink with the load, whether the engine supplies 1 kW or 10 kW. Below roughly 30–40% load, fuel per kWh therefore rises steeply. A diesel that idles along for long periods can also wet-stack, leaving unburnt fuel in the exhaust. Inverter generators soften the effect by slowing the engine when demand is low.
Generator electricity: what is the price per kWh?
Diesel at €1.60/L puts the fuel cost of a small set at about €0.55–0.70 per kWh under typical loads. Add maintenance and engine wear and you reach €0.65–1.00/kWh. A big prime-power set at high load can go as low as €0.40–0.50/kWh, still well above most grid tariffs.
Off-grid, is solar with a battery cheaper than a generator?
For everyday use, usually yes. Lifetime cost of solar plus a lithium battery typically lands at €0.12–0.30/kWh, since nothing has to be bought for fuel. Generators keep a role for long overcast periods and occasional heavy loads, and many hybrid systems combine both.
What are the CO₂ emissions of a diesel generator?
Each litre of diesel burned releases about 2.68 kg of CO₂. Assuming 2.4 kWh from that litre, each kWh carries roughly 1.1 kg, which is two to four times a typical European grid.

Sources & references

  1. HOMER Energy (UL) — Generator fuel curve (intercept and slope coefficients)
  2. US EPA — Emission factors for greenhouse gas inventories
  3. US DOE — Generators and backup power (energy saver)
  4. IRENA — Off-grid renewable energy solutions

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.