Two forces in tension
Choosing between a heat pump and a gas boiler pits cheaper running against dearer installation. Per kWh of heat, a heat pump costs much less to operate unless power is very pricey, yet its upfront bill is considerably higher. A fair test therefore spans the whole ownership period rather than one year’s bill. The calculator compares both systems over 15 years (adjustable), counting:
- fuel use: for the heat pump, demand divided by SCOP; for the boiler, demand divided by its seasonal efficiency;
- individual price paths for electricity and gas (in the EU, gas could rise faster after ETS2, the carbon price for buildings, begins);
- upfront cost after grants;
- maintenance, rising 2% yearly;
- the gas standing charge, which stops only when you disconnect from the network;
- replacement of equipment wearing out within the period;
- CO₂ from each system.
Results include cumulative cost curves, the crossover year, discounted total cost of ownership (NPV) and the electricity/gas price ratio at which yearly running costs match.
Equations
Sample comparison
Default inputs are 12,000 kWh of heat a year, SCOP 3.2, a 90% condensing boiler, electricity at 0.28 €/kWh and gas at 0.10 €/kWh. That means 3,750 kWh of electricity for the heat pump (1,050 €) against 13,333 kWh of gas for the boiler (1,333 €).
Include servicing (150 € for the heat pump, 120 € for the boiler) and a 110 € gas standing charge, which falls away on disconnection. First-year running costs then reach ≈ 1,200 € with the heat pump and ≈ 1,563 € with the boiler, about 363 € apart.
Purchase prices: 10,000 € for the heat pump (13,000 € minus a 3,000 € grant) and 3,500 € for a new boiler, so 6,500 € extra. Electricity prices rise 2% a year and gas 3%. On those paths the heat pump’s running total drops under the boiler’s after about 12.7 years, and at year 15 it is ahead by roughly 1,670 € nominal. At a 4% discount rate the totals nearly meet (25,160 € against 24,490 €), so grant and prices decide the result.
Your ratio works out as 0.28 ÷ 0.10 = 2.8, against a break-even of 3.77 (3.56 on energy alone, lifted by the saved gas standing charge). Yearly CO₂ falls from 2.44 t to 1.31 t on a 350 g/kWh grid: some 17 t in total across 15 years.
Reading the numbers
- Headline, the 15-year cost gap: a positive value favours the heat pump over the period, including every cost.
- Break-even year: the point where yearly savings have paid back the higher purchase price. Set it beside the heat pump’s 15–20-year life.
- Break-even ratio versus yours: the further yours lies below, the better the investment survives price changes.
- NPV of TCO discounts future costs and thus favours the cheaper-upfront option; a mortgage or savings rate is a sensible choice.
- Running cost versus electricity price chart: the crossing marks the electricity price above which gas is cheaper to run.
Country snapshot
| Country, 2024–25 (approx.) | Price ratio, electricity to gas | Break-even at SCOP 3.2 | Usual outcome |
|---|---|---|---|
| United Kingdom | 3.5–4.0 | 3.6 | Close call on running cost; the grant tips it |
| Germany | 2.5–3.0 | 3.6 | Lower running cost with heat pump |
| France | 2.0–2.5 | 3.6 | Clear running-cost advantage |
| Netherlands | 2.0–2.5 | 3.6 | Clear running-cost advantage |
| Sweden / Norway | 1.5–2.5 | 3.6 | Heat pump leads by a wide margin |
| United States (average) | 3.0–3.5 | 3.6 | Varies a lot by state |
Because ratios track tariffs, look at your own bills. Heat-pump or time-of-use rates may lower the effective ratio by 20–40%.
Advice from the model
- Time it with a boiler failure. When the old unit dies, the real choice is heat pump versus new boiler, which is the default case here.
- Raise SCOP. Larger radiators plus weather compensation may raise SCOP from 2.7 to 3.5, a bigger win than most tariff changes. The heat pump calculator can estimate your own.
- Disconnect from gas when cooking is electric; the standing charge by itself often runs 100–150 a year.
- Cut demand first. Any kWh of heat avoided by insulation reduces both running cost and the heat pump you need.
- Check every fuel. Without a gas supply, the heating cost comparison puts oil, LPG and pellets side by side.
Assumptions
SCOP and boiler efficiency stay constant throughout, so a poorly commissioned heat pump or oversized boiler may underperform. Carbon intensity of the grid does not change in the model, which makes CO₂ savings conservative. Left out: financing, property value, cooling by reversible units and any future gas-network levies. Prices vary widely between countries and homes; collect at least two installation quotes and use them.
Method & assumptions
Both systems start from the same heat demand. Heat pump electricity: demand ÷ SCOP. Boiler gas: demand ÷ seasonal efficiency. Year-1 running cost includes maintenance and the standing charge (for gas, and for the heat pump when it keeps the connection). Over the years electricity and gas escalate at their own rates, maintenance grows 2%/yr and equipment is renewed like for like at end of life.
The point where annual running costs coincide is the ratio r* = [Q/η·pgas − ΔF] / (Q/SCOP) / pgas of electricity to gas price; ΔF stands for the heat pump's additional fixed cost (maintenance minus any standing charge saved). With no fixed costs it reduces to r* = SCOP ÷ η.
Frequently asked questions
Does a heat pump cost less than gas heating?
At what electricity/gas price ratio does a heat pump pay off?
Service life: heat pump or gas boiler?
Do heat pumps cost more to maintain?
CO₂ saving of a heat pump over gas?
Should a working boiler be replaced?
Sources & references
Embed this calculator
Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.