Converters & physics calculator

Convert gas between m³, kWh, therms, MMBtu and kg

Handles natural gas, LNG, propane, butane, biomethane and hydrogen, moving between gas volume, energy and weight or liquid volume. Pick gross or net calorific value for the basis.

Editable share link Branded PDF report Free · no sign-up

Results

Converting 1,000 m³ of Natural gas (pipeline) gives 10,972.2 kWh, using the gross basis at 39.5 MJ/m³.
1,000 m³ =
10,972.2kWh
Energy
10,972kWh (gross)
Energy
39.5GJ
Therms
374.388
MMBtu
37.4388
Standard volume
1,000Sm³
Cubic feet
35,315ft³
Mass
757kg
As liquid
1,682.2litres
if liquefied (LNG)
CO₂ when burned
2,081.8kg
stoichiometric, fossil

1,000 m³ in every unit

UnitValue1 m³ =
Cubic metres (Sm³, 15 °C)1,0001
Normal cubic metres (Nm³, 0 °C)947.9440.947944
Cubic feet (ft³)35,314.735.3147
Hundred cubic feet (ccf)353.1470.353147
Thousands of cubic feet (Mcf)35.31470.0353147
Kilowatt-hours (kWh)10,972.210.9722
Megawatt-hours (MWh)10.97220.0109722
Megajoules (MJ)39,50039.5
Gigajoules (GJ)39.50.0395
Therms (thm)374.3880.374388
Dekatherms (Dth)37.43880.0374388
British thermal units (BTU)37,438,80037,438.8
Million BTU (MMBtu)37.43880.0374388
Kilograms (kg)7570.757
Tonnes (t)0.7570.000757
Pounds (lb)1,668.91.6689
Litres of liquefied gas (LNG/LPG)1,682.221.68222
US gallons of liquid444.3960.444396

For reference: one unit of each gas (gross)

GasMJ/Sm³kWh/Sm³MJ/kgkWh/kgkg/Sm³Net/gross
Natural gas (pipeline)39.510.9752.214.490.7570.902
LNG (regasified natural gas)40.511.2554150.750.903
Propane (LPG)9526.3950.313.981.8870.92
Butane (LPG)12233.8949.613.782.460.923
Biomethane (upgraded biogas)37.810.55214.440.7270.9
Hydrogen12.13.3614239.450.0850.846
  • All volumes are standard m³ at 15 °C and 1.01325 bar. Gas in a Nm³ (0 °C) is denser by 5.5%. In the US, ft³ is usually taken at 60 °F, which is practically 15 °C.
  • Gas composition is not constant. H-gas from Russia or Norway runs about 39–41 MJ/m³ gross, Dutch L-gas about 35 and LNG cargoes 39–43. Where accuracy matters, take the value off your bill.
  • Handy equivalents: 3.6 MJ and 3,412 BTU make up 1 kWh; a therm is 100,000 BTU or 29.3071 kWh; an MMBtu is 10 therms or 1.055 GJ.

Three quantities behind every gas unit

Utilities and traders each pick their own gas unit. Metering gives m³ or ft³. Suppliers invoice in kWh or therms. Markets price MMBtu. Tankers carry tonnes of LNG, and propane comes by litre or gallon. These are really volume, energy and mass, and moving between the three needs knowledge about the gas itself.

Inside the tool, everything passes through gross energy in MJ: the input is turned into MJ, which is then turned into the requested unit. Three gas properties make that possible:

  • gross calorific value, in MJ per standard m³, for volume to energy;
  • gas density, in kg per standard m³, for volume to mass;
  • liquid density (kg per litre), needed when LNG or LPG is kept as a liquid.

Pick natural gas, LNG, propane, butane, biomethane or hydrogen and its properties are filled in for you. Your supplier’s own numbers can replace them in the advanced options. The energy basis switch flips between gross (billing practice) and net (IEA and EU statistics). A full table gives the amount in all 18 units simultaneously.

Formulas

Energy (MJ, gross) = V(Sm³) × CV Mass (kg) = V(Sm³) × ρ_gas Liquid volume (L) = Mass ÷ ρ_liquid

1 Nm³ = 1.0549 Sm³ 1 ft³ = 0.0283168 m³ 1 kWh = 3.6 MJ 1 therm = 100,000 BTU = 29.3071 kWh 1 MMBtu = 293.071 kWh Net energy = gross energy × (NCV/GCV) ≈ 0.90 for natural gas

Sample conversion

Input: 1,000 m³ of pipeline natural gas with a gross CV of 39.5 MJ/m³.

  • 1,000 × 39.5 gives 39,500 MJ, i.e. 39.5 GJ or 10,972 kWh.
  • Divide 10,972 by 29.3071 for 374.4 therms (37.44 MMBtu).
  • In imperial volume, 1,000 ÷ 0.0283168 = 35,315 ft³, or 35.3 Mcf.
  • Weight: 0.757 kg/m³ makes 757 kg. Liquefy it at 0.45 kg/L and it fits in about 1,682 litres, some 600 times smaller.
  • Burning that gas emits roughly 2,080 kg of CO₂.

Count on the net basis and the same quantity reads about 9,900 kWh. Nothing physical changed, only the bookkeeping.

Reading the screen

  • The large tile shows the answer in your target unit.
  • Smaller tiles show the usual equivalents, covering energy (kWh, GJ, therms, MMBtu), volume (standard and cubic feet), mass and liquid volume.
  • The table of all units includes the value of one input unit too, handy for a spreadsheet of your own.
  • The comparison table sets gases side by side per m³ and per kg. Per m³, propane holds about 2.4 times natural gas’s energy and hydrogen under a third; per kg, hydrogen leads by a wide margin.

Property table

Fuel gas Gross CV, MJ/m³ kWh per m³ kWh per kg Density, kg/m³
H-gas natural gas 38–42 10.5–11.7 14–15 0.72–0.80
Dutch L-gas natural gas 33–36 9.2–10.0 12–13 0.78–0.83
Regasified LNG 39–43 10.8–11.9 15 0.73–0.78
Propane ≈ 95 ≈ 26.4 ≈ 14.0 1.88
Butane ≈ 122 ≈ 33.9 ≈ 13.8 2.46
Hydrogen ≈ 12.1 ≈ 3.4 ≈ 39.4 0.085

Avoiding errors

  • Prefer your bill’s calorific value. Network operators measure it all the time, and it may sit a few percent away from the default.
  • Watch reference conditions. Industrial deals tend to use Nm³ at 0 °C; household meters in effect report near 15 °C. A mix-up costs 5.5%.
  • Stay on one basis. A net-based boiler efficiency paired with a gross-based price inflates efficiency by about 10%, the reason condensing boilers get called “over 100% efficient” on a net basis.
  • For bill checks, use the gas cost calculator; it applies the volume correction factor added to household bills.
  • Comparing fuels? See the heating cost comparison, which restates every fuel as cost per useful kWh.

Limits

Composition shifts with the source and over time, so mass and volume results from the defaults are typical rather than exact. Both calorific value and density are treated as constants at standard conditions, so pressurised cylinders and high-pressure real-gas compressibility fall outside the tool. LPG commonly mixes propane and butane, so for blends type intermediate values in the advanced options. CO₂ is stoichiometric combustion only, without upstream methane leaks.

In a billing dispute, rely on the calorific value and correction factor shown on the bill itself; suppliers publish daily or monthly averages for each network zone. For trades and LNG contracts, find out whether the price is per MMBtu gross (US and Asian practice) or per MWh gross (European hubs like TTF and NBP) and convert both sides on the same basis.

Method & assumptions

Everything is first brought to gross energy in MJ. Gas volume is multiplied by calorific value; a mass is divided by density and multiplied by CV; liquid litres are multiplied by liquid density, divided by gas density, then multiplied by CV. Energy units convert straight across, with net values divided by the net/gross ratio. To get the unit you want, the same chain is applied in reverse.

Frequently asked questions

Energy in a cubic metre of natural gas?
Gross (higher heating value), 10.5–11.5 kWh. Take a standard cubic metre at a typical 39.5 MJ; divide by 3.6 and you get 10.97 kWh. Switch to the net (lower heating value) basis and the answer shrinks by about a tenth, to around 9.9 kWh.
Converting a therm to kWh?
29.3071 kWh, exactly. The therm is defined as 100,000 BTU, and a kWh equals 3,412.14 BTU. A dekatherm is ten therms and equals one MMBtu (1.055 GJ).
Sm³ vs Nm³ vs plain m³ for gas?
Same unit of volume, different measuring conditions. Sm³ means 15 °C and 1.01325 bar; Nm³ means 0 °C at that pressure. Colder gas is more compact, which is why an Nm³ holds about 5.5% more gas than an Sm³.
Higher or lower calorific value, which one counts?
It depends on the water produced when gas burns. The gross (higher) figure adds the heat recovered as that vapour condenses; the net (lower) figure does not. Natural gas nets out at roughly 90% of gross and propane at about 92%. Bills in the UK and the US are gross-based, while IEA and Eurostat generally publish net.
How much gas comes from a tonne of LNG?
Somewhere between 1,300 and 1,400 standard cubic metres, according to composition. That tonne contains about 54 GJ gross, equal to roughly 15,000 kWh or 51 MMBtu.
kWh per gallon of propane?
A US gallon holds 26.8 kWh, or around 91,500 BTU gross. As a liquid at 15 °C that gallon weighs close to 1.92 kg (4.2 lb).
Is one Mcf the same as one MMBtu?
They differ slightly. Typical US pipeline gas carries about 1.03–1.04 MMBtu in each Mcf (1,000 cubic feet), and the precise ratio follows the gas's heating value, an input in the advanced options.

Sources & references

  1. US EIA — Units and calculators explained: natural gas
  2. UK DESNZ — Digest of UK Energy Statistics (DUKES), Annex A: energy and commodity balances, conversion factors
  3. NIST — Guide for the Use of the International System of Units (SI), Special Publication 811

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.