Scope
About a third of the world’s electricity still comes from coal. Questions about a plant nearly always follow the same chain: how many MWh go to the grid, how much coal that burns, and what comes out of the stack and into the ash pond. This tool follows that chain from your inputs (net capacity, capacity factor, efficiency, coal quality) to coal per hour, day and year, the accompanying CO₂, ash and SO₂, and the short-run cost of one MWh, with and without carbon pricing.
The formula
Heat input per MWh (GJ) = 3.6 ÷ net efficiency Coal per MWh (t) = heat input ÷ net calorific value (GJ/t) CO₂ per MWh (t) = heat input × emission factor (kg/GJ) ÷ 1,000
SO₂ (t) = coal × sulphur fraction × 2 × (1 − FGD removal) Ash (t) = coal × ash fraction
Short-run cost per MWh = coal per MWh × coal price + CO₂ per MWh × carbon price + variable O&M
Why multiply by 2 for SO₂? Sulphur at 32 kg turns into SO₂ at 64 kg. Heating values and emission factors follow IPCC 2006 defaults for each rank: bituminous coal has 25.8 GJ/t and 94.6 kg CO₂/GJ; lignite has 11.9 GJ/t and 101 kg/GJ.
Example: the default plant
A 600 MW supercritical unit, 39% net efficiency, 60% capacity factor, burning bituminous coal rated 25.8 GJ/t (net) that costs 110/t delivered.
- Annual output is 600 × 8,760 × 0.60, giving 3.15 TWh.
- Each MWh needs 3.6 ÷ 0.39 = 9.23 GJ of heat.
- At 25.8 GJ/t that is 0.358 t of coal per MWh. Yearly: 1.13 million t, 3,100 t a day, 215 t an hour through the mills when running flat out.
- 9.23 × 94.6 = 873 kg CO₂ for each MWh, 2.75 Mt over the year.
- Ash, assuming 12%: roughly 135,000 t. SO₂ with 0.8% sulphur and 95% FGD removal: around 900 t, or 18,000 t if no scrubbers were fitted.
- Fuel costs 0.358 × 110 = €39.4/MWh. Add €4 of variable O&M for €43.4/MWh excluding carbon.
Put carbon at 80 €/t and its cost alone is €70/MWh, more than the coal. After 2021 that arithmetic moved coal down the merit order in a good part of Europe.
Why the coal grade dominates
No input changes tonnage as much as rank does. Run the same 600 MW unit on lignite (11.9 GJ/t) and the requirement more than doubles to about 2.4 million t a year, with a little more CO₂ per GJ too. Lignite is therefore burned at or beside the mine; carrying a wet fuel of such low energy density any distance is uneconomic. Seaborne coal is priced by heating value. Benchmarks from Newcastle and Richards Bay are about 6,000 kcal/kg NAR (net as received, roughly 25.1 GJ/t), whereas Indonesian sub-bituminous grades sit at 3,800–4,200 kcal/kg. Convert kcal/kg to GJ/t with 0.004187.
Laboratory reports use varying bases too (as received, air dried, dry, dry ash-free). What the tool wants is the as-received net value, the one that counts the moisture entering the boiler.
Typical values
| Plant type | Net efficiency (LHV) | Coal per MWh (bituminous) | CO₂ per MWh |
|---|---|---|---|
| Old small subcritical | 28–32% | 0.44–0.50 t | 1,050–1,200 kg |
| Subcritical, 300–600 MW | 33–37% | 0.38–0.42 t | 920–1,030 kg |
| Supercritical | 38–41% | 0.34–0.37 t | 830–900 kg |
| Ultra-supercritical | 42–46% | 0.30–0.33 t | 740–810 kg |
| Lignite (modern supercritical) | 40–43% | 0.75–0.85 t of lignite | 850–1,000 kg |
Where each output is useful
- The annual coal figure feeds supply contracts, rail and port planning.
- Per-MWh coal and CO₂ intensity are the numbers for plant-to-plant comparison. A heat rate calculator does the same for gas.
- Gross capacity is what the generator produces before the plant takes its own share. That share, for mills, fans, pumps and flue gas desulphurisation, runs at 6–10%.
- The stacked cost chart (fuel, carbon, variable O&M) is short-run marginal cost, which sets merit-order position. It is not the full cost; the LCOE calculator gives that.
Limitations
The model keeps efficiency constant. In practice a unit gives up two to four percentage points at low load and on starts, which is where cycling coal plants now spend a lot of time. Each shipment has its own calorific value, ash and sulphur. NOₓ, mercury and particulates hinge on the control equipment and are left out. Only combustion CO₂ is counted; adding mining methane and transport emissions would raise it by about 5–15% on a lifecycle view. For carbon pricing across any fuel mix, use the carbon tax calculator.
Method & assumptions
Each MWh sent out burns fuel heat of 3.6 GJ ÷ net efficiency. Divided by the NCV of coal as received, that gives tonnes per MWh. A year's tonnage = MW × 8,760 × capacity factor × tonnes per MWh. Ash is simply coal × ash content. Sulphur dioxide follows from the coal's sulphur: coal × sulphur × 2 (ratio of molecular masses) × (1 − FGD removal). Carbon dioxide = heat input × emission factor (kg/GJ). For the running cost per MWh, add fuel, carbon and variable O&M to get the short-run marginal cost.
Frequently asked questions
Coal consumption of a 1,000 MW plant in a year
Tonnes of coal per megawatt-hour
Emissions of CO₂ from coal-fired generation per MWh
Typical efficiency of a coal plant
Coal trains needed to feed a power station
Fuel and carbon cost of coal power
Sources & references
Embed this calculator