Results

Operating at 60% capacity factor, this 600 MW plant exports 3.15 TWh per year. It consumes about 1.13 million tonnes of coal, equal to 3,091 t daily or around 113 unit trains of 10,000 t. CO₂ output is 2.75 Mt, or 873 kg for every MWh. Adding fuel, carbon and variable O&M gives 43.4 €/MWh.
Coal burned per year
1.13Mt
3,091 t per day on average
Coal per MWh
358kg/MWh
NCV 25.8 GJ/t ≈ 6,162 kcal/kg
Coal at full load
215t/h
Annual net generation
3.15TWh
5,256 full-load hours
Gross capacity
645MW
45 MW auxiliary load
CO₂ per year
2.75Mt
CO₂ intensity
873kg/MWh
Ash produced
135kt/yr
SO₂ after FGD
903t/yr
18.1 kt without FGD
Fuel cost per MWh
39.4€/MWh
Carbon cost per MWh
0€/MWh
Annual fuel bill
124million €
Short-run cost per MWh (€)
Yearly coal burn and CO₂ against efficiency

The same plant on other coals

CoalNCV (GJ/t)Coal (Mt/yr)CO₂ (kg/MWh)Fuel cost /MWh
Bituminous (thermal grade, about 6,000 kcal/kg GAR)25.81.1387339.4
Sub-bituminous (~4,500 kcal/kg)18.91.5488729.3
Lignite / brown coal11.92.4593215.5
Anthracite26.71.0990751.9
  • Heating values and CO₂ factors are IPCC 2006 defaults for each coal rank. Real coals differ, for example Indonesian sub-bituminous at 3,800–5,000 kcal/kg. Take the NCV from your own coal analysis, as received.
  • Treat the coal prices as typical delivered figures. Since 2020, seaborne thermal coal has swung between under 60 and over 400 USD/t.

Scope

About a third of the world’s electricity still comes from coal. Questions about a plant nearly always follow the same chain: how many MWh go to the grid, how much coal that burns, and what comes out of the stack and into the ash pond. This tool follows that chain from your inputs (net capacity, capacity factor, efficiency, coal quality) to coal per hour, day and year, the accompanying CO₂, ash and SO₂, and the short-run cost of one MWh, with and without carbon pricing.

The formula

Annual generation (MWh) = net MW × 8,760 h × capacity factor

Heat input per MWh (GJ) = 3.6 ÷ net efficiency Coal per MWh (t) = heat input ÷ net calorific value (GJ/t) CO₂ per MWh (t) = heat input × emission factor (kg/GJ) ÷ 1,000

SO₂ (t) = coal × sulphur fraction × 2 × (1 − FGD removal) Ash (t) = coal × ash fraction

Short-run cost per MWh = coal per MWh × coal price + CO₂ per MWh × carbon price + variable O&M

Why multiply by 2 for SO₂? Sulphur at 32 kg turns into SO₂ at 64 kg. Heating values and emission factors follow IPCC 2006 defaults for each rank: bituminous coal has 25.8 GJ/t and 94.6 kg CO₂/GJ; lignite has 11.9 GJ/t and 101 kg/GJ.

Example: the default plant

A 600 MW supercritical unit, 39% net efficiency, 60% capacity factor, burning bituminous coal rated 25.8 GJ/t (net) that costs 110/t delivered.

  1. Annual output is 600 × 8,760 × 0.60, giving 3.15 TWh.
  2. Each MWh needs 3.6 ÷ 0.39 = 9.23 GJ of heat.
  3. At 25.8 GJ/t that is 0.358 t of coal per MWh. Yearly: 1.13 million t, 3,100 t a day, 215 t an hour through the mills when running flat out.
  4. 9.23 × 94.6 = 873 kg CO₂ for each MWh, 2.75 Mt over the year.
  5. Ash, assuming 12%: roughly 135,000 t. SO₂ with 0.8% sulphur and 95% FGD removal: around 900 t, or 18,000 t if no scrubbers were fitted.
  6. Fuel costs 0.358 × 110 = €39.4/MWh. Add €4 of variable O&M for €43.4/MWh excluding carbon.

Put carbon at 80 €/t and its cost alone is €70/MWh, more than the coal. After 2021 that arithmetic moved coal down the merit order in a good part of Europe.

Why the coal grade dominates

No input changes tonnage as much as rank does. Run the same 600 MW unit on lignite (11.9 GJ/t) and the requirement more than doubles to about 2.4 million t a year, with a little more CO₂ per GJ too. Lignite is therefore burned at or beside the mine; carrying a wet fuel of such low energy density any distance is uneconomic. Seaborne coal is priced by heating value. Benchmarks from Newcastle and Richards Bay are about 6,000 kcal/kg NAR (net as received, roughly 25.1 GJ/t), whereas Indonesian sub-bituminous grades sit at 3,800–4,200 kcal/kg. Convert kcal/kg to GJ/t with 0.004187.

Laboratory reports use varying bases too (as received, air dried, dry, dry ash-free). What the tool wants is the as-received net value, the one that counts the moisture entering the boiler.

Typical values

Plant type Net efficiency (LHV) Coal per MWh (bituminous) CO₂ per MWh
Old small subcritical 28–32% 0.44–0.50 t 1,050–1,200 kg
Subcritical, 300–600 MW 33–37% 0.38–0.42 t 920–1,030 kg
Supercritical 38–41% 0.34–0.37 t 830–900 kg
Ultra-supercritical 42–46% 0.30–0.33 t 740–810 kg
Lignite (modern supercritical) 40–43% 0.75–0.85 t of lignite 850–1,000 kg

Where each output is useful

  • The annual coal figure feeds supply contracts, rail and port planning.
  • Per-MWh coal and CO₂ intensity are the numbers for plant-to-plant comparison. A heat rate calculator does the same for gas.
  • Gross capacity is what the generator produces before the plant takes its own share. That share, for mills, fans, pumps and flue gas desulphurisation, runs at 6–10%.
  • The stacked cost chart (fuel, carbon, variable O&M) is short-run marginal cost, which sets merit-order position. It is not the full cost; the LCOE calculator gives that.

Limitations

The model keeps efficiency constant. In practice a unit gives up two to four percentage points at low load and on starts, which is where cycling coal plants now spend a lot of time. Each shipment has its own calorific value, ash and sulphur. NOₓ, mercury and particulates hinge on the control equipment and are left out. Only combustion CO₂ is counted; adding mining methane and transport emissions would raise it by about 5–15% on a lifecycle view. For carbon pricing across any fuel mix, use the carbon tax calculator.

Method & assumptions

Each MWh sent out burns fuel heat of 3.6 GJ ÷ net efficiency. Divided by the NCV of coal as received, that gives tonnes per MWh. A year's tonnage = MW × 8,760 × capacity factor × tonnes per MWh. Ash is simply coal × ash content. Sulphur dioxide follows from the coal's sulphur: coal × sulphur × 2 (ratio of molecular masses) × (1 − FGD removal). Carbon dioxide = heat input × emission factor (kg/GJ). For the running cost per MWh, add fuel, carbon and variable O&M to get the short-run marginal cost.

Frequently asked questions

Coal consumption of a 1,000 MW plant in a year
Expect 2.5–3.5 Mt of bituminous coal when the plant runs at 70–80% load factor, the spread coming from efficiency and fuel grade. Best case: an ultra-supercritical unit (43% efficient, 23.5 GJ/t coal, 70% load factor) burns about 2.2 Mt. Worst case: an old subcritical lignite unit, which can top 8 Mt.
Tonnes of coal per megawatt-hour
Good bituminous coal: 0.33–0.40 t. Sub-bituminous: 0.45–0.55 t. Lignite: 0.8–1.2 t. To get the exact number, compute 3.6 GJ ÷ efficiency ÷ calorific value; a 39% plant on 25.8 GJ/t coal lands at 0.36 t.
Emissions of CO₂ from coal-fired generation per MWh
Hard coal typically gives 750–1,000 kg for each MWh delivered to the grid, lignite 950–1,200 kg. What moves the figure most is efficiency: one extra percentage point lowers it by about 2–3%.
Typical efficiency of a coal plant
Net, on an LHV basis: 30–36% for old subcritical, 38–41% for supercritical, 42–45% for ultra-supercritical. Because many old, small units remain in service, coal plants worldwide average only about 37%.
Coal trains needed to feed a power station
One unit train, 100 wagons, hauls about 10,000 t. At 60% load a 600 MW station consumes roughly 1.1 Mt in a year, which works out at two such trains each week. Stations on the coast are supplied by sea instead, where a single Capesize carrier holds some 150,000–180,000 t.
Fuel and carbon cost of coal power
Coal alone costs 25–60 per MWh (USD or EUR) at usual delivered prices. Add carbon: about 0.9 t CO₂ for each MWh multiplied by the price, so 80 €/t gives roughly €70/MWh, which exceeds the fuel line. Capital and fixed O&M come on top and are handled in the LCOE calculator.

Sources & references

  1. IPCC 2006 Guidelines, Vol. 2 Energy, ch. 1 — default calorific values and CO₂ emission factors for coal
  2. IEA — Coal 2024: analysis and forecast
  3. US EIA — Electric Power Annual: heat rates and fuel receipts of coal plants