Heating & gas calculator

Work out gas kWh and cost from your meter readings

Two meter readings (m³, ft³, kWh or therms) are turned into kWh using calorific value and volume correction the way suppliers do, then priced with unit rate, standing charge and VAT. One bill also lets you project annual consumption.

Editable share link Branded PDF report Free · no sign-up

Results

154 m³ equals 1,728 kWh. Your 31-day bill comes to about 182.1 €, or 0.105 € per kWh all-in. A January bill like this points to roughly 10,900 kWh over a year.
Total bill
€182
31 days, standing charge included
Energy used
1,728kWh
55.7 kWh per day
Volume
154m³
5,438 ft³
Therms
59
Energy charge
€173
0.1 €/kWh
Standing charge
€9.30
VAT
€0.00
All-in price per kWh
0.1054€/kWh
Cost per day
€5.87
Estimated annual use
10,932kWh/yr
≈ 1,203 €/yr
CO₂ from this gas
316kg
0.183 kg/kWh (gross)
Bill breakdown
Estimated gas consumption across the year

Conversion steps

StepValue
Units used154 m³
Volume correction× 1.02264 = 157.49 m³
Calorific value× 39.5 MJ/m³ = 6,221 MJ
Convert to kWh÷ 3.6 = 1,728 kWh
Energy charge1,728 kWh × 0.1 = 172.8 €
Standing charge31 days × 0.3 = 9.3 €
VAT0% = 0 €
Total182.1 €
  • To get kWh, multiply m³ by the volume correction and the calorific value (MJ/m³), then divide by 3.6. British suppliers must apply this calculation; much of Europe uses the equivalent “Zustandszahl” × “Brennwert”.
  • The yearly estimate follows a typical heating profile for a temperate climate (January ≈ 15% of annual use, July ≈ 2.5%). If gas only feeds the cooker and hot water, the profile is much flatter.

Why a gas bill needs a conversion

What the meter counts is volume, but what you pay for is energy, so every bill quietly turns cubic metres (or cubic feet) into kilowatt-hours. This calculator repeats the legally required supplier method and then builds the bill line by line.

  1. Consumption. Enter two readings, or a usage figure you already know. You can use m³, hundreds of cubic feet, cubic feet, kWh or therms (the unit on US bills).
  2. Energy. After conversion to standard cubic metres, the volume is multiplied by the volume correction factor (temperature and pressure) and by the gas’s calorific value, then divided by 3.6, which turns megajoules into kWh.
  3. Charges. The price basis can be kWh, m³ or therm. For every day in the period a standing charge is added; separate levies and any discount follow, and VAT or sales tax comes last.
  4. Yearly figure. Pick the month of your bill, and a typical temperate-climate profile scales it up to a year, giving a rough idea of annual cost from one winter bill.

Formula

kWh = V(m³) × correction factor × calorific value (MJ/m³) ÷ 3.6

V(m³) = imperial units × 100 × 0.0283168 (hundreds of ft³) kWh = therms × 29.3071

Bill = (kWh × unit price + kWh × levies + days × standing charge − discount) × (1 + VAT)

UK domestic meters use a fixed correction factor of 1.02264. Germany handles the same step with the Zustandszahl (usually 0.95–0.97) and calls the calorific value the Brennwert. Other countries sometimes fold both into one “conversion coefficient” on the bill. If that is your case, use it as the correction factor and match the calorific value to it.

Defaults worked through

Take a metric meter that goes from 4,215 to 4,369, so 154 m³ used in a 31-day billing period in January.

  • 154 m³ × 1.02264 = 157.49 m³ corrected
  • 157.49 × 39.5 MJ/m³ = 6,221 MJ
  • 6,221 ÷ 3.6 gives 1,728 kWh, i.e. about 55.7 kWh per day or 59 therms

At €0.10/kWh the energy part comes to €172.80. The standing charge, €0.30/day for 31 days, adds €9.30, so the bill is about €182.10, an all-in €0.105 per kWh. Since January usually represents around 15.5% of annual gas, the bill implies roughly 10,900 kWh a year, near €1,200 at unchanged prices. The CO₂ released by that month’s gas is about 316 kg (0.183 kg/kWh).

Understanding the outputs

  • Total bill: what the period should cost, fixed charges and tax included.
  • Energy used (kWh): set it against your bill and against other fuels. If your supplier’s figure differs by more than a few percent, look at the calorific value and at whether the meter is imperial.
  • All-in price per kWh: the standing charge divided across your usage. Expect it to sit above the unit rate, and to jump in summer when consumption drops.
  • Estimated annual use: a rough indication from one bill. A home using gas just for cooking or hot water has a flatter profile, so the figure overshoots there.
  • Conversion steps: each multiplication is listed, which helps when you want to query a bill.

Typical values

Item Typical range
Calorific value (gross) 37.5–43 MJ/m³ (UK usually 39–40)
Energy per m³ 10.5–11.5 kWh
Energy per 100 ft³ 30–32 kWh
1 therm 29.31 kWh
Annual use, flat 4,000–8,000 kWh
Annual use, 3-bed house 10,000–15,000 kWh
Annual use, large or old house 18,000–30,000 kWh
January share of annual use 14–17%
July share of annual use 2–4%

Lowering the gas bill

  • Take your own readings. Estimated bills wander off; a real reading every month or two keeps control and gives the annual estimate meaning.
  • Thermostat down by 1 °C. Each degree usually saves 5–10% of the gas used for heating.
  • Run the boiler at a lower flow temperature. Condensing boilers condense, and hit their rated efficiency, only if return water is under about 55 °C, so a flow of 50–60 °C often saves a few percent at no cost.
  • Insulate first. Loft and cavity wall insulation pay back quickest; put numbers on it with the insulation savings calculator.
  • Consider a different fuel. Whether a switch pays off is something the heating cost comparison and heat pump vs gas boiler can answer.

What the estimate ignores

Because calorific value changes between billing periods, using one value introduces roughly ±1–2% error. One correction factor cannot reflect how each country adjusts for altitude or meter temperature. The yearly figure assumes a temperate, heating-led profile and ignores how the year’s weather actually turned out. Tiered rates, time-of-use pricing and monthly caps lie outside the model. The gas unit converter is the tool for plain unit changes with no bill involved.

Method & assumptions

From a meter reading to kWh: begin with the volume in m³ (for ft³, multiply by 0.0283168), then kWh = V × correction factor × calorific value ÷ 3.6. The bill is the unit price on those kWh, plus days × standing charge, plus levies, and VAT goes on last. For reference, a therm equals 29.3071 kWh (100,000 BTU).

Frequently asked questions

How can I turn my gas meter readings into kWh?
Work out consumption by taking the earlier reading away from the later one. Metric meters read in cubic metres directly. Imperial ones read in hundreds of cubic feet, so 2.83 turns each unit into m³. Then convert: kWh = m³ × 1.02264 (volume correction) × calorific value (MJ/m³, as printed on your bill) ÷ 3.6. At the typical 39.5 MJ/m³, one m³ delivers about 11.2 kWh.
What is the kWh value of 1 m³ of gas?
Between about 10.5 and 11.5 kWh, as the calorific value of the gas and your country's volume correction both play a part. Using the UK method (correction 1.02264, CV 39.5 MJ/m³) the result is 11.22 kWh, whereas a German bill with a Zustandszahl near 0.96 and a Brennwert near 11.2 kWh/m³ ends up close to 10.8 kWh.
What does the calorific value on a gas bill mean?
This number tells you the energy held by each cubic metre of gas delivered locally, in megajoules per cubic metre and on a gross basis (so the heat from condensing water vapour counts). The network operator tracks it continuously; values mostly lie between 37.5 and 43 MJ/m³ and shift slightly between bills.
Standing charge: what is it?
It is a flat daily amount that pays for your property's connection to the gas network, along with metering and billing. You owe it even if you use no gas, which is why it can dominate a small summer bill. Only a full disconnection from gas avoids it.
What is the usual yearly gas consumption of a house?
Gas-heated houses in temperate Europe usually consume about 8,000–15,000 kWh yearly, with 11,500 kWh being the UK regulator's typical medium value. At the extremes, big, old or badly insulated homes can pass 20,000 kWh, and a flat that cooks with gas but has no gas heating can stay below 1,000 kWh.
Winter versus summer gas bills
Heating is the main gas consumer and rises as the weather gets colder, so January can cost five to six times as much as July, when gas is left with hot water and cooking. Scaling one bill to a full year is done with a typical monthly heating profile.

Sources & references

  1. Ofgem: Typical Domestic Consumption Values
  2. UK Government: Gas (Calculation of Thermal Energy) Regulations 1996
  3. UK DESNZ: Greenhouse gas reporting: conversion factors 2024
  4. US EIA: Natural gas explained: units and calculators

Embed this calculator