Your bill never shows it, but every kilowatt-hour has a CO₂ weight attached. The carbon intensity of electricity can differ more than thirtyfold between countries and shifts through the day as the wind drops or the sun sets. It decides whether switching to an electric car or heat pump is a large climate win or only a small one, companies need it for emissions reporting, and it is the simplest way to judge a country’s power-sector clean-up. This guide shows how the number is built, where countries stand and how to use it without misleading yourself.
How the figure is worked out
Example grid: 40% gas (490 g), 30% wind (11 g), 20% nuclear (12 g), 10% coal (820 g) = 0.4×490 + 0.3×11 + 0.2×12 + 0.1×820 = 196 + 3.3 + 2.4 + 82 ≈ 284 g CO₂e/kWh
Any published value rests on four choices:
- Direct versus life-cycle. Direct factors count stack emissions only, so wind, solar, hydro and nuclear read zero. Life-cycle factors also include construction, fuel supply and methane leaks; Ember and Our World in Data publish these as CO₂e, using IPCC medians.
- Generation versus consumption. Consumption-based values adjust for cross-border imports and exports.
- Losses. Typical grid losses of 5–10% raise the intensity of power at your socket. The UK’s DESNZ conversion factors, for example, show generation and transmission/distribution losses on separate lines.
- Averaging period. A single annual average conceals big swings between hours and seasons.
Emission factors by power source
IPCC AR5 life-cycle medians, in g CO₂e/kWh, with typical ranges in brackets:
- Coal (pulverised): 820 (740–1,000, lignite higher).
- Oil: about 650–750 (600–900).
- Natural gas (CCGT): 490 (410–650, depending on methane leakage).
- Dedicated biomass: 230 (very wide, since feedstock and accounting rules matter).
- Utility solar PV: 48 (20–50 in newer studies).
- Geothermal: 38 (6–80, some fields higher).
- Concentrated solar power: 27 (9–63).
- Hydropower: 24 (from 1 to over 2,000 for tropical reservoirs).
- Nuclear: 12 (4–110).
- Offshore wind: 12 (8–35).
- Onshore wind: 11 (7–56).
UNECE (2021) reports lower figures for solar PV (~8–40 g) and nuclear (~5–6 g), thanks to cleaner manufacturing and supply chains.
Country by country
Latest-year values (mostly 2025) from Ember / Our World in Data, in g CO₂e/kWh:
- Coal-heavy, above 500: South Africa ~700, with coal supplying ~81% of power. Indonesia ~680 (coal ~62%, then gas). India ~670 (coal ~71%). Poland ~589 (about half coal, plus wind and solar). China ~525 and Australia ~525; China is ~54% coal with hydro, solar and wind, Australia mixes coal, solar, wind and gas.
- Middle band, 300–500: Japan ~477 on gas and coal. The world average ~458 sits here, with coal at 33% and gas at 22%. The United States ~384 relies on gas, nuclear, coal and wind. Germany ~330 combines wind, solar, coal and gas.
- Lower, 50–300: Italy ~285 (gas, hydro, solar). Romania ~251 (hydro, nuclear, gas, wind). The United Kingdom ~217 (gas, wind, nuclear). Canada ~191 (hydro, nuclear, gas). Spain ~154 (solar, wind, nuclear, gas). Denmark ~114, where wind provides ~58% plus solar and biomass. Brazil ~110 (hydro, wind, solar).
- Cleanest, below 50: France ~41, about 69% nuclear plus hydro and wind. Sweden ~35 on hydro, nuclear and wind. Iceland ~28 and Norway ~28; Iceland uses hydro and geothermal, Norway ~90% hydro plus wind. Paraguay ~25, with ~99% hydro.
Full time series live on each country’s page. Start from the country index, line nations up on the rankings or browse the world energy map.
How intensity has changed since 2000
In 2000 the global average stood near 527 g CO₂e/kWh. It crested at roughly 540–545 g between 2007 and 2012 while Asian coal expanded, then slid to about 458 g in 2025 (Ember / OWID). Low-carbon sources (renewables plus nuclear) supplied about 33% of power in 2010 and roughly 43% in 2025, almost all of the gain coming from solar and wind. Absolute power-sector emissions are still near a record of about 14.6 Gt CO₂e, since demand keeps growing.
Some countries have moved far faster. The UK has cut intensity by roughly 60% since 2012 with coal’s exit, and Denmark went from 400–500 g in the early 2000s to nearly 100 g. Poland, Germany and the United States have come down as well. The explorer charts any country’s path.
Average or marginal: which one applies
Average intensity shares a grid’s emissions equally among all users, which makes it your slice of the total. Marginal intensity is about the change: what happens if one more kWh is demanded. Wind and solar already run flat out, so the responding plant is normally a fossil one. If gas is on the margin, marginal intensity can reach 350–450 g/kWh against a 150 g average. During curtailment of surplus wind or solar, though, extra demand may carry a marginal figure near zero.
Match the measure to your question:
- Footprint of your household’s electricity: the annual, location-based average.
- Corporate scope 2 reports: the location-based average, plus a market-based figure reflecting contracts, per the GHG Protocol.
- Deciding when to charge an EV or run a heat pump: hourly average or a marginal signal.
- Emissions avoided by a new solar farm or efficiency programme: long-run marginal emissions.
Hour-by-hour swings
Within one day the figure can vary threefold or more. In Germany, hours with strong sun and wind may fall below 100 g/kWh and still, dark winter evenings can exceed 500 g/kWh. California sees midday solar push intensity down, then gas takes over at night. Moving flexible demand (EV charging, heat pump preheating, water heating, batteries) to the cleaner hours therefore cuts emissions and often costs too. Many grid operators and apps show live and forecast figures.
Working out your own footprint
Example: 3,500 kWh/yr in Germany (330 g) = 1,155 kg CO₂e Same household in France (41 g) = 144 kg; in Poland (589 g) = 2,062 kg
Worked case: heat pump or gas boiler?
- Gas boiler, 90% efficient: 202 g/kWh of gas ÷ 0.9 ≈ 225 g CO₂ per kWh of heat (more with methane leakage).
- A heat pump with SPF 3.2: grid intensity ÷ 3.2.
Heat pump emissions per kWh of heat, and the cut compared with the boiler:
- France (41 g): 13 g, down 94%.
- UK (217 g): 68 g, down 70%.
- Germany (330 g): 103 g, down 54%.
- World average (458 g): 143 g, down 36%.
- India (670 g): 209 g, down 7%.
Even on a coal-dominated grid, an efficient heat pump about matches a gas boiler, and it gets cleaner each year with the grid. Run your own figures through the electricity CO₂ calculator, the heat pump vs gas boiler calculator or the EV vs petrol car calculator.
Common errors to avoid
- CO₂ versus CO₂e. Direct factors generally count CO₂ only; life-cycle factors add methane and nitrous oxide as CO₂-equivalent. Do not compare one country’s CO₂-only number with another’s life-cycle CO₂e.
- Outdated data. Grids change fast. A decade back, the UK and Germany emitted 40–60% more per kWh than today, so a 2015 factor overstates present emissions.
- Forgetting losses. A factor taken at the plant gate leaves out transmission and distribution losses. Add 5–10% for a per-kWh value at your meter.
- Using a national average for self-generation. Rooftop solar consumed on site never enters the grid, so apply the grid factor to net imports only.
- Swapping marginal for average. A new load is not automatically clean because the average is low, nor dirty because coal is on the margin. Say which figure you use, and why.
- Looking only at today. A heat pump or EV lasts 10–20 years, so the average over that period counts, and in most countries it will fall well below today’s. Grid-operator projections or IEA scenarios offer a sensible range.
- Double counting renewables. If a supplier sells you wind-farm certificates, that output should be removed from the residual mix applied to everyone else. A few countries issue a “residual mix” factor to handle this.
Green tariffs and the market-based method
Under the GHG Protocol a company reports scope 2 twice, location-based (the grid average) and market-based (reflecting what it has contracted: renewable energy certificates, Guarantees of Origin and PPAs). Critics note that certificates rarely pay for new generation; abundant Norwegian hydro certificates have held European prices very low for years. Tougher standards include:
- Additionality: the contract must back a new project that would not exist otherwise.
- 24/7 hourly matching: consumption is matched with clean supply in the same hour and grid region. Some large technology firms have set it as a target, and it is part of the debate on revising the GHG Protocol.
- Emissionality: new capacity goes where it displaces the most fossil output.
In a home the dependable levers are lower consumption, cleaner timing and your own generation; the solar panel calculator estimates what a roof can produce.
Key takeaways
What electrification achieves depends on grid intensity, since that sets the real emissions of an EV, heat pump or data centre. Hydro and nuclear grids sit below 50 g/kWh, coal-heavy ones reach about 700 g, and the world average of about 460 g is dropping as solar and wind spread. Annual averages suit footprints, hourly signals suit timing, and marginal values suit judging interventions. Look up your country in the rankings and add up your own emissions in the carbon footprint calculator.
Calculators related to this topic
Frequently asked questions
What does carbon intensity of electricity mean?
Which country has the cleanest electricity?
Average versus marginal emissions: what separates them?
Generation-based or consumption-based intensity: which should I use?
How many grams of CO₂ come from 1 kWh of electricity?
Is electricity on a green tariff really zero-carbon?
Sources & references
- Ember — Global Electricity Review 2025 and Electricity Data Explorer
- Our World in Data — Carbon intensity of electricity generation
- IPCC AR5 WGIII Annex III — Technology-specific life-cycle emissions
- UNECE (2021). Life Cycle Assessment of Electricity Generation Options
- UK DESNZ / DEFRA — Greenhouse gas reporting: conversion factors 2025
- Greenhouse Gas Protocol — Scope 2 Guidance
The figures in this guide are typical ranges taken from the listed sources, and your own values will vary with location, prices and equipment. For estimates specific to your site, use the linked calculators.