Roughly 20% of the light that reaches a solar panel leaves as electricity. The panel itself is just glass, silicon and an aluminium frame, with nothing that moves. Even so, 6 kWp facing south in central Europe typically makes 5,500–7,000 kWh a year, close to a normal household’s consumption there. The sections below follow the energy from the first photon to your kettle, then look at losses and at how to predict what a real system will produce.

How a cell turns light into current

Silicon is used in over 95% of panels sold worldwide (Fraunhofer ISE Photovoltaics Report). Its band gap is about 1.12 electron-volts. Light made of photons above that energy can eject an electron from the crystal lattice and leave a positive “hole” behind, which in wavelength terms means anything shorter than about 1,100 nm: visible light plus some near infrared.

On its own, a freed electron would find a hole again within microseconds and waste its energy as heat. The p-n junction is the fix. Manufacturers dope one side of the wafer with boron (p-type, surplus holes) and the other with phosphorus (n-type, surplus electrons). At the border a built-in electric field pushes electrons toward the n-side and holes toward the p-side. Connect a wire across the two sides and the electrons flow through it, which is the current you can use.

This explains two hard limits. Photons below the band gap are wasted: they pass through or merely warm the cell. Photons above it free only a single electron each, and the extra energy turns to heat (thermalisation). The theoretical ceiling for one silicon junction is therefore around 29–30%, per the Shockley–Queisser analysis adapted to silicon. To see how far real products get and what could raise it, read the solar panel efficiency guide.

From a single cell to a finished module

Cell voltage barely depends on size: about 0.6–0.7 V with no load and 0.5–0.6 V at maximum power. Current does depend on size and sunshine, reaching roughly 10–18 A for a modern 182 mm or 210 mm cell in full sun. Linking cells in series raises the voltage to a usable level.

What a 2024–2026 home-use module is made of:

  • 108–144 half-cut monocrystalline cells, doing the conversion to DC
  • 3.2 mm tempered glass with an anti-reflective coating (about 94–96% light transmission)
  • EVA or POE film that glues the layers together and blocks moisture
  • a polymer backsheet, or 2 mm rear glass in glass-glass designs
  • an anodised aluminium frame
  • a junction box with 3 bypass diodes, which limit the damage from partial shade

Typical rating: 400–480 Wp on about 1.7–2.0 m².

Cutting cells in half halves the current in each cell string. Resistive losses rise with current squared, so they drop sharply, and shading hurts less. When one third of a module is shaded, its bypass diode routes the current around that section, which keeps the module from falling to the level of its weakest cell.

Reading a Wp rating

The nameplate in watts-peak comes from a flash test at Standard Test Conditions (STC): 1,000 W/m² irradiance, 25 °C cell temperature and the AM1.5 reference spectrum. It is a lab number. On a clear summer noon a well-angled European panel does get 1,000–1,100 W/m², but its cells will sit 30–40 °C above 25 °C, so even then you usually see only 80–90% of the rating.

Inverters

What comes out of the panels is DC at a voltage that moves with light and temperature. Households run on AC: 230 V/50 Hz in Europe, 120/240 V/60 Hz in North America. The inverter converts, and it also does maximum power point tracking (MPPT). On a module’s current-voltage curve there is one “knee” where V × I is greatest. Clouds and warming keep moving it, so the inverter keeps re-tuning. The AC side is a synchronised sine wave, and good string inverters reach European weighted efficiencies of 96–98%.

You will see three designs:

  • String inverter: a single central unit takes in series strings of typically 8–20 modules at 300–1,000 V DC. It is the cheapest option per watt, though one shaded module weakens its whole string.
  • Microinverters: one small unit per module or pair, so each module tracks its own optimum. Better for shaded or complicated roofs, and pricier.
  • String inverter with DC optimisers: module-level tracking plus a central inverter, a middle path.

A hybrid inverter adds a battery connection for storing surplus midday energy. To work out a battery size, use the solar battery calculator.

At the consumer unit

The inverter feeds your fuse board, and electricity takes the easiest route. The fridge, heat pump or washing machine running at that moment gets the power first. What is left flows through the meter to the grid, and the grid covers any shortfall when the house needs more than the panels give. Nothing needs to be switched; it just happens.

Hence self-consumption matters most for the payback. Power used on site saves you the retail price (often €0.20–0.40 per kWh in Europe); power sent out earns, at best, a feed-in tariff or a net-metering credit. Try different export rules in the net metering calculator to see the effect.

Grid-tied inverters also have to disconnect within a fraction of a second if the grid goes down, so that utility workers are safe (anti-islanding protection). So an ordinary solar installation has no output in a blackout, unless it includes a battery with backup capability.

Where the power disappears

Picture a square metre of panel under 1,000 W of sunlight, the STC level. Less than a fifth of that reaches the socket, and the steps below show why:

  1. Module efficiency of 20–23% means 77–80% of the light is not converted. About 215 W remains.
  2. Cell temperatures of 50–60 °C cost 6–12%, leaving about 195 W.
  3. Dust, soiling and snow take 1–5%: about 190 W.
  4. Mismatch, cabling and connectors take 2–4%: about 184 W.
  5. The inverter loses 2–4%: about 178 W.
  6. Weak-light and angle-of-incidence effects remove another 2–4%: about 173 W.

Everything downstream of the module is summarised by the performance ratio (PR), the fraction of nameplate-based energy that actually arrives at the AC meter. Good modern designs reach 75–88%. A value below 70% generally means shading, a fault or poor design.

Predicting annual yield

You need only two things: yearly irradiation on the panel plane at your location, and the PR.

E_year (kWh) = P_peak (kWp) × H_poa (kWh/m²/year) / 1 kW/m² × PR where H_poa = annual solar irradiation on the panel plane PR = performance ratio (typically 0.75–0.88) Specific yield (kWh/kWp) = E_year / P_peak = H_poa × PR

Example: 6 kWp in Hamburg, Bucharest and Seville

Assume tilt close to optimal and PR 0.80. Irradiation values at optimal tilt are approximate, based on PVGIS (JRC) and NREL’s PVWatts.

  • Hamburg, Germany: 1,150–1,250 kWh/m²/yr gives a specific yield of 920–1,000 kWh/kWp, so 5,500–6,000 kWh a year.
  • Bucharest, Romania: 1,500–1,600 gives 1,200–1,280, so 7,200–7,700 kWh.
  • Seville, Spain: 2,000–2,150 gives 1,600–1,720, so 9,600–10,300 kWh.

Bucharest worked through: 6 kWp × 1,550 kWh/m² × 0.80 ≈ 7,440 kWh per year. The same panels make about 75% more in Seville than in Hamburg, which shows that location beats any other design decision. The solar panel calculator runs an hourly simulation with satellite weather for your address. If you are starting from your bill, how many solar panels do I need gives a module count, and the Energy Explorer shows the solar resource for any point you click.

Direction, angle and shade

  • Azimuth: facing the equator (south in the northern hemisphere) collects the most over a year. East or west costs typically 10–20% at mid-latitudes, but moves output to the morning or evening.
  • Tilt: the annual optimum at mid-latitudes is usually 30–40°, slightly below the latitude. A miss of ±10–15° costs only a few per cent. Details are in the guide to the best angle for solar panels and the solar tilt angle calculator.
  • Shade: the loss people most often underrate. As cells are in series, shadow across one row can remove a third or more of a module’s output before the bypass diode acts. In winter, a chimney shadow over two modules can outweigh a 10° tilt mistake.

Ageing

Silicon modules fade slowly. The causes are light-induced degradation in the first hours of sun (1–3% in some older p-type cells, far less in modern n-type), UV yellowing of encapsulants, micro-cracks from thermal cycling and, in hot, humid climates, potential-induced degradation. Jordan and Kurtz (NREL, 2013) analysed nearly 2,000 published rates and reported a median of about 0.5% per year; premium n-type modules are warranted at 0.3–0.4%.

Expect to replace the inverter once. String inverters last 10–15 years, and microinverters often come with 20–25-year warranties.

Beyond silicon

  • Thin film (CdTe, CIGS): an absorber a few micrometres thick on glass. CdTe is widely used in US utility plants, with module efficiencies of about 19–20%.
  • Perovskite-on-silicon tandems: perovskite takes blue light, silicon the red. Lab cells have passed 33% on NREL’s Best Research-Cell Efficiency Chart, but long-term durability in commercial products is unproven.
  • Bifacial modules: glass-glass panels that also pick up light reflected onto the back. Gains are roughly 5–15% over bright ground (white roofs, sand, snow) and much smaller over dark roofs.

Key takeaways

  • The p-n junction splits light-freed electrons and creates DC; series-connected cells make a module, and the inverter produces grid-quality AC.
  • Wp is a laboratory figure. Actual energy depends on local irradiation and a performance ratio of about 0.75–0.88.
  • Location sets the ceiling, from under 1,000 kWh/kWp in northern Europe to over 1,700 in deserts. Compare places on the world energy map or in the country profiles.
  • Heat, shading and inverter losses are what you can control, and good design pays back more than premium panels.

Calculators related to this topic

Frequently asked questions

What makes a solar panel produce electricity?
Inside each cell, a thin silicon layer absorbs light. Photons above a threshold energy free electrons, and the p-n junction's built-in field makes them flow one way. Contacts on the cell gather this direct current (DC), which an inverter then converts to the alternating current (AC) that appliances and the grid expect.
Can solar panels still produce power under cloud?
Yes, at reduced output. Under thin cloud a panel can give 30–60% of what it would in clear sky; under thick overcast, typically 5–20%. Scattered, diffuse light still counts, and this is how German or British systems manage 850–1,100 kWh per kWp annually.
Do solar panels produce anything at night?
No. A photovoltaic cell needs light, so after sunset the power for your home has to come from the grid, from net-metering credit or from a battery topped up earlier in the day.
Why does heat reduce solar panel output?
Voltage falls as a silicon cell warms. Crystalline modules shed about 0.25–0.40% of their power for each °C over 25 °C. Roof-mounted cells in sunshine commonly run at 45–65 °C, which at a summer midday takes off 5–15% of output.
What is the lifespan of a solar panel?
Warranties on mainstream crystalline silicon modules run 25–30 years and usually guarantee 80–90% of rated power at the end of the term. In the NREL review by Jordan and Kurtz (2013), median degradation came out near 0.5% a year, and many panels keep working past the 30-year mark.
How is kWp different from kW for solar panels?
kWp (kilowatt-peak) states what a panel or array produces in laboratory Standard Test Conditions: 1,000 W/m² of light with cells held at 25 °C. It is a label, not a promise. On a normal day the light is weaker and the cells hotter, so actual power is usually below it.

Sources & references

  1. Fraunhofer ISE — Photovoltaics Report (updated regularly)
  2. NREL — Best Research-Cell Efficiency Chart
  3. Jordan, D. C. & Kurtz, S. R. (2013). Photovoltaic Degradation Rates — an Analytical Review. Progress in Photovoltaics 21(1)
  4. PVEducation.org — online textbook on photovoltaic devices (Honsberg & Bowden)
  5. IEA — Solar PV tracking page