Testing every angle instead of guessing
Ask around and you will hear that the tilt should match the latitude. It makes a reasonable first guess and rarely lands exactly right, because the best angle also hinges on direct versus diffuse sunlight, on which season gets the clear days, on how hot the modules get in summer and on the compass direction they face. This page therefore skips the shortcut and simulates each angle in turn.
The tool fetches a year of hourly NASA POWER satellite weather for your coordinates. It feeds it into the same PV model that drives the solar panel calculator, once for each tilt between 0° and 90° (5° steps), then narrows the winner down in 1° steps. The sweep is repeated for the winter half-year, the summer half-year, every month, and thirteen compass directions running from east via south to west. That adds up to about 80 full 8,760-hour simulations per request. Inverter clipping is disabled, so any gap between angles reflects only geometry and weather.
Equations behind it
cos θ = cos Z · cos β + sin Z · sin β · cos(γ_sun − γ_panel) Annual yield(β, γ) = Σ_hours P_ac( G_poa, T_cell )
Definitions: β = tilt, γ = azimuth, Z = solar zenith angle, θ = incidence angle on the module, ρ = ground albedo, A = Hay–Davies anisotropy index (the portion of diffuse light that comes straight from the sun’s direction). Tilting up helps with the low winter sun (cos θ) but narrows the view of the sky ((1 + cos β)/2). Your best angle sits where those two forces cancel over a typical year.
Case study: south-facing array in Bucharest
Inputs: 44.4°N, due south, TOPCon modules, 14% system losses, weather from 2024. Outcome:
- The annual optimum is 35°, producing 1,222 kWh/kWp, which is 6,110 kWh for a 5 kWp plant. The latitude rule would have said 37°, near but a touch steep.
- A common 30° pitch costs just 0.3%, 25° costs 1.1% and 45° costs 1.2%. Lying flat costs 13.6%; a vertical façade, 32%.
- For winter (Oct–Mar) the best tilt is 56°, for summer (Apr–Sep) 21°. A twice-yearly switch gains 3.5%, four settings gain 3.8%, a monthly routine 4.6%.
- Turn the array east at 35° and you keep roughly 80% of the best yield; south-east keeps about 95%.
What the numbers tell you
- The best fixed tilt matters for ground frames and flat-roof mounts. Pitched roofs seldom offer a choice, so enter your tilt and read off the loss, normally small.
- Monthly optimum tilt ranges from about 10–15° in June up to 60–65° in December at mid-latitudes. Off-grid systems need to cope with December, which is why they are installed steeply.
- Orientation sensitivity reveals how fast output declines as you rotate away from the equator. Stay within ±30° of south and the loss is usually below 5%.
- Use the tilt × orientation matrix to look up each face of a roof.
Best fixed tilt by city, panels facing the equator
| City | Latitude | Best year-round tilt | Best winter tilt | Loss if mounted flat |
|---|---|---|---|---|
| Singapore | 1°N | 0–10° | 10–15° | 0 to −2% |
| Phoenix, USA | 33°N | 29–32° | 48–52° | −11 to −13% |
| Madrid, Spain | 40°N | 32–35° | 50–55° | −12 to −15% |
| Bucharest, Romania | 44°N | 33–36° | 55–58° | −13 to −14% |
| Berlin, Germany | 52°N | 35–40° | 55–62° | −12 to −16% |
| Helsinki, Finland | 60°N | 38–44° | 62–70° | −15 to −20% |
| Sydney, Australia | 34°S | 28–32° | 48–52° | −10 to −12% |
Rules of thumb
- A taller frame on a roof rarely pays. Raising modules from 25° to 35° adds about 1%, while wind load, price and looks all get worse.
- Try to keep at least 10–15°. Rain cleans the glass and snow slips away. Nearly flat arrays also lose another 1–3% to dust in dry regions.
- On a flat roof, a lower angle can win. Rows tilted 10–15° may stand far closer than rows at 35° without casting shade, so each square metre of roof often yields more kWh (see the solar roof area calculator).
- If the system is off-grid, tune for winter: choose Winter half-year above, and the off-grid solar calculator will dimension the array for the weakest month.
- For solar water heating, collectors set about 10° above latitude trade summer overheating against winter output. The solar water heater calculator goes into that.
Where it falls short
One weather year is used (pick any back to 2001), and the best tilt normally shifts only 1–3° between years. Obstructions on the horizon, trees and buildings are ignored, though they can move the optimum; a mountain to the south, for example, pushes it steeper. Snow lying on flat panels, bifacial gain and row shading on flat roofs are not simulated. NASA POWER cells are about 50 km across, so coastal fog and valley effects are averaged away.
Method & assumptions
Hourly NASA data (irradiance, temperature, wind) for one year is downloaded once. Then the whole PV chain runs repeatedly: NOAA sun position → Hay–Davies transposition → ASHRAE incidence-angle modifier → cell temperature → temperature-corrected DC → losses. The tilts tested are 0–90° in 5° steps, with 1° steps close to the winner. The runs are repeated for the winter and summer half-years and for azimuths up to ±90° off the equator-facing direction. Clipping is switched off, which leaves geometry and climate as the only differences between cases.
Seasonal gains show what you would gain by changing the tilt twice a year, four times a year or monthly, compared with one fixed angle set at the annual optimum.
Frequently asked questions
What is the best tilt for solar panels?
What does a badly angled roof cost me in output?
How steep should panels be to catch winter sun?
Should I change the angle through the year?
What angle in degrees does a 6/12 pitch correspond to?
Does an east-west panel layout make sense?
Sources & references
- NASA POWER — hourly solar and meteorological data
- Jacobson, M.Z. & Jadhav, V. (2018). World estimates of PV optimal tilt angles and ratios of sunlight incident upon tilted and tracked PV panels relative to horizontal panels. Solar Energy 169
- European Commission JRC — PVGIS (optimal inclination and orientation)
- Hay, J.E. & Davies, J.A. (1980). Calculation of the solar radiation incident on an inclined surface