Solar calculator

Net metering, net billing or feed-in tariff: which pays your solar exports best?

Learn what exporting solar power is really worth. The model nets month by month, rolls kWh or money credits over, applies a year-end true-up, and counts non-nettable network charges and fixed fees for each scheme side by side.

Editable share link Branded PDF report Free · no sign-up

Results

The cheapest bill comes from Net metering: 176 € per year, which is 1,170 € less than with no solar. Under Feed-in (net export) the saving would be 585 €, so the two differ by 585 €/yr and an exported kWh is valued somewhere from 0.06 to 0.227 €.
Best: Net metering
€1,170
annual saving · bill 176 €
Bill without solar
€1,346
5,000 kWh + fixed charges
Net metering bill
€176
saves 1,170 €
Net billing bill
€691
saves 655 €
Feed-in bill
€761
saves 585 €
Self-consumed solar
1,500kWh
worth 375 € in every scheme
Exported / imported
3,500 / 3,500kWh
Worth of one solar kWh (best scheme)
0.234€/kWh
export worth 0.227 €/kWh
NM credit forfeited
0kWh
381 kWh paid at 0.04 €
Solar vs consumption
100%
within your use
Yearly electricity bill under each scheme
Grid exchange per month and the net-metering credit bank

Scheme comparison

SchemeAnnual bill (€)Saving (€)Per solar kWhPer exported kWh
Net metering1761,1700.2340.227
Net billing6916550.1310.08
Feed-in (net export)7615850.1170.06

Month by month

MonthSolarUseImportExportNM bank kWhNB credit €NM billNB billFiT bill
Jan2304894201610073100103
Feb29641532620700387377
Mar4314343053020096066
Apr501391241351110084047
May561391223393280083240
Jun551371205386460082836
Jul586391216410655082937
Aug571391220400834083139
Sep471383242330923084249
Oct376417304263881086368
Nov230436367161675088790
Dec19548943113700-7105107
  • Net metering offsets imports against exports one kWh for one kWh within each month, but non-nettable charges still hit every imported kWh. Net billing pays exports as a money credit that reduces energy charges only, not fixed fees. Feed-in means imports are billed at the full price while exports earn the feed-in rate.
  • Monthly solar profile: SE Europe / US Midwest (≈ 44°). Self-consumption is held at 30% of each month's output (limited to that month's consumption). For an hourly self-use estimate, try the solar battery calculator.
  • Schemes differ from one utility or country to the next (netting period, rollover, minimum bills, tax on credits). Take the numbers from your own tariff sheet.

Identical panels, unequal bills

Savings from one solar system can differ widely between two identical houses. What separates them is the compensation scheme, which sets the value of each exported kilowatt-hour. You get one household simulated month by month under every common scheme, with the yearly bill printed for each.

Yearly output is shared out over the months by a seasonal curve suited to your climate, while a consumption profile describes your home (flat, lighting-driven, electric heating or air conditioning). Within a month, what you use straight away is self-consumed, the surplus is exported and the shortfall imported. The four rule sets below are then applied.

Scheme How it settles
Net metering Exports cancel imports kWh for kWh. Surplus is banked and carried forward, paid out monthly or forfeited, and the bank is closed once a year on the true-up date. Non-nettable network charges apply to all imported kWh.
Net billing Each exported kWh becomes a money credit at the export rate. The credit reduces energy charges but not the fixed fee, and any unused part rolls over, lapses monthly or is paid at year end.
Feed-in (net export) Imports are billed at retail, and exports are paid separately at the feed-in price.
Gross feed-in (optional) All production is sold at a fixed tariff, and all consumption is bought from the grid.

Equations

Self-consumed_m = min(production_m × direct share, consumption_m) Import_m = consumption_m − self_m Export_m = production_m − self_m

Net metering: billable_m = import_m − export_m − bank_(m−1) bill_m = fixed + import_m × p × nn% + max(0, billable_m) × p × (1 − nn%) bank_m = max(0, −billable_m) → leftover × true-up rate at year end Net billing: bill_m = fixed + max(0, import_m × p − export_m × p_export − credit_(m−1)) Feed-in: bill_m = fixed + import_m × p − export_m × p_FiT

Case study: a balanced home

Our preset home needs 5,000 kWh a year and owns a system generating the same, in a south-east European climate. It consumes 30% of output directly (1,500 kWh), exports 3,500 kWh and imports 3,500 kWh. At €0.25/kWh plus €8 a month, the bill without solar is about €1,346.

Scheme Annual bill Saving Notes
Net metering about €176 €1,170 Bank starts to fill in April, peaks near 920 kWh in September, still holds 381 kWh at a January true-up, bought back at just €0.04/kWh
Net billing at €0.08 per exported kWh €691 €655
Feed-in at €0.06/kWh €761 €585

Under any scheme the 1,500 kWh used directly are worth €375. The rest depends on the 3,500 exported kWh: net metering values them at about €0.23 each, the other schemes at €0.06–0.08. Start the netting year in April (advanced option) and the summer bank carries over into winter, lifting the saving to about €1,250.

Reading the results

Output What to take from it
Value per exported kWh Use it for sizing and the battery decision. Close to retail, exporting is fine; near a quarter of retail, raise self-consumption as far as possible
NM credit forfeited Anything above zero means the system outgrows your annual use or the true-up month strands credit
Monthly chart Plots imports, exports and the net-metering bank; a big bank on the true-up date is lost value

Compensation schemes compared

Typical saving per solar kWh Export value Scheme (examples)
0.9–1.0 × retail 100% of retail energy price Full retail net metering (many US states, historic EU schemes)
0.6–0.8 × retail 50–70% of retail Net metering, network fees not netted
0.35–0.6 × retail 20–40% of retail Net billing at wholesale/avoided cost
0.3–0.55 × retail 10–35% of retail Net-export feed-in tariff
equals self-consumed share only 0 No payment for exports

Advice for owners

  • Tariff sheet first. Minimum bills, rollover rules, taxes on credits, the netting interval and the true-up date often decide the outcome.
  • If you have net metering, size the system to your annual use, because surplus is paid only at the true-up rate.
  • If you have net billing or feed-in, run the dishwasher, laundry, water heater and EV charger around midday, or evaluate a battery.
  • For the production figure, the solar panel calculator is the place to start. To get a believable self-consumption share, use the hourly simulation in the battery calculator with the battery set to zero.
  • Grandfathering: in many regions an existing system stays on the old scheme for 10–20 years after a rule change.

Limitations

Limit Effect
Monthly steps, fixed self-consumption share Real self-consumption shifts with weather and habits, so an hourly analysis may differ by a few percent
Time-of-use prices, demand charges, export limits, taxes on credits, minimum bills Not modelled one by one; approximate them via the price, the fixed charge and the non-nettable share
Seasonal curves Represent a climate band, not your own roof

Method & assumptions

Annual output and use are first allocated to months by typical profiles. For each month: self-consumed = min(consumption, production × direct share); import = consumption − self-consumed; export = production − self-consumed.

Net metering bills import − export − banked credit in kWh. If the result is positive it is charged at the nettable price. If negative, it is banked, paid or forfeited as your rule dictates, and December's remaining balance is settled at the true-up rate. Net billing works as credit = carried credit + export × export price, then bill = fixed + max(0, import × price − credit). Feed-in gives bill = fixed + import × price − export × feed-in price. Savings use the same household without solar as the benchmark.

Frequently asked questions

How does net billing differ from net metering?
Net metering swaps kWh for kWh, so every export earns the full retail price. Net billing instead credits money at a lower export rate, frequently pegged to wholesale or avoided cost, and that credit usually reduces only the energy part of the bill, not fixed fees. For an identical system, expect exports to be worth 30–60% less under net billing.
When does the true-up happen in net metering?
Sunny-month surplus goes into a kWh bank that pays off imports later. The account is settled annually. On that true-up date any credit you have not used is either dropped or bought at a low avoided-cost rate, and net consumption is invoiced. Because the bank swells in summer, a date in early spring lets it carry you through winter. Pick January and part of the summer and autumn credit may be left stranded.
Net metering versus a feed-in tariff, which is better for a home owner?
Net metering nearly always wins for the prosumer. Under a net-export feed-in tariff you receive only the feed-in price for exports while paying full retail on imports. Gross feed-in in Germany, Italy and Spain started out generous, with all production bought at a fixed premium price; today new contracts seldom beat the retail rate.
Should I build a system bigger than my consumption under net metering?
Generally no. Output above your yearly use earns a low true-up rate or nothing, so the last panels you add repay far less than the first. A sensible target is 90–100% of annual consumption, with extra if an EV or heat pump is on the way.
Is a battery worth adding to a net metering setup?
Rarely, when the goal is saving money. Where the grid credits surplus at full retail value, a battery just adds losses and expense. Net billing and low feed-in prices change that, because a kWh used at home is then worth far more than an exported one. Wanting backup power is another reason.
What is the non-nettable percentage?
Some schemes net the energy component alone. Network fees, levies and taxes remain due on every imported kWh, however much you exported. Type that fraction into the tool; at 40% non-nettable, a netted kWh is worth just 60% of retail.

Sources & references

  1. U.S. DOE — Net metering policies (Database of State Incentives for Renewables & Efficiency)
  2. European Commission — Directive (EU) 2019/944, Article 15 on active customers and net billing
  3. IRENA — Net billing schemes, Innovation landscape brief (2019)

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.