Identical panels, unequal bills
Savings from one solar system can differ widely between two identical houses. What separates them is the compensation scheme, which sets the value of each exported kilowatt-hour. You get one household simulated month by month under every common scheme, with the yearly bill printed for each.
Yearly output is shared out over the months by a seasonal curve suited to your climate, while a consumption profile describes your home (flat, lighting-driven, electric heating or air conditioning). Within a month, what you use straight away is self-consumed, the surplus is exported and the shortfall imported. The four rule sets below are then applied.
| Scheme | How it settles |
|---|---|
| Net metering | Exports cancel imports kWh for kWh. Surplus is banked and carried forward, paid out monthly or forfeited, and the bank is closed once a year on the true-up date. Non-nettable network charges apply to all imported kWh. |
| Net billing | Each exported kWh becomes a money credit at the export rate. The credit reduces energy charges but not the fixed fee, and any unused part rolls over, lapses monthly or is paid at year end. |
| Feed-in (net export) | Imports are billed at retail, and exports are paid separately at the feed-in price. |
| Gross feed-in (optional) | All production is sold at a fixed tariff, and all consumption is bought from the grid. |
Equations
Net metering: billable_m = import_m − export_m − bank_(m−1) bill_m = fixed + import_m × p × nn% + max(0, billable_m) × p × (1 − nn%) bank_m = max(0, −billable_m) → leftover × true-up rate at year end Net billing: bill_m = fixed + max(0, import_m × p − export_m × p_export − credit_(m−1)) Feed-in: bill_m = fixed + import_m × p − export_m × p_FiT
Case study: a balanced home
Our preset home needs 5,000 kWh a year and owns a system generating the same, in a south-east European climate. It consumes 30% of output directly (1,500 kWh), exports 3,500 kWh and imports 3,500 kWh. At €0.25/kWh plus €8 a month, the bill without solar is about €1,346.
| Scheme | Annual bill | Saving | Notes |
|---|---|---|---|
| Net metering | about €176 | €1,170 | Bank starts to fill in April, peaks near 920 kWh in September, still holds 381 kWh at a January true-up, bought back at just €0.04/kWh |
| Net billing at €0.08 per exported kWh | €691 | €655 | |
| Feed-in at €0.06/kWh | €761 | €585 |
Under any scheme the 1,500 kWh used directly are worth €375. The rest depends on the 3,500 exported kWh: net metering values them at about €0.23 each, the other schemes at €0.06–0.08. Start the netting year in April (advanced option) and the summer bank carries over into winter, lifting the saving to about €1,250.
Reading the results
| Output | What to take from it |
|---|---|
| Value per exported kWh | Use it for sizing and the battery decision. Close to retail, exporting is fine; near a quarter of retail, raise self-consumption as far as possible |
| NM credit forfeited | Anything above zero means the system outgrows your annual use or the true-up month strands credit |
| Monthly chart | Plots imports, exports and the net-metering bank; a big bank on the true-up date is lost value |
Compensation schemes compared
| Typical saving per solar kWh | Export value | Scheme (examples) |
|---|---|---|
| 0.9–1.0 × retail | 100% of retail energy price | Full retail net metering (many US states, historic EU schemes) |
| 0.6–0.8 × retail | 50–70% of retail | Net metering, network fees not netted |
| 0.35–0.6 × retail | 20–40% of retail | Net billing at wholesale/avoided cost |
| 0.3–0.55 × retail | 10–35% of retail | Net-export feed-in tariff |
| equals self-consumed share only | 0 | No payment for exports |
Advice for owners
- Tariff sheet first. Minimum bills, rollover rules, taxes on credits, the netting interval and the true-up date often decide the outcome.
- If you have net metering, size the system to your annual use, because surplus is paid only at the true-up rate.
- If you have net billing or feed-in, run the dishwasher, laundry, water heater and EV charger around midday, or evaluate a battery.
- For the production figure, the solar panel calculator is the place to start. To get a believable self-consumption share, use the hourly simulation in the battery calculator with the battery set to zero.
- Grandfathering: in many regions an existing system stays on the old scheme for 10–20 years after a rule change.
Limitations
| Limit | Effect |
|---|---|
| Monthly steps, fixed self-consumption share | Real self-consumption shifts with weather and habits, so an hourly analysis may differ by a few percent |
| Time-of-use prices, demand charges, export limits, taxes on credits, minimum bills | Not modelled one by one; approximate them via the price, the fixed charge and the non-nettable share |
| Seasonal curves | Represent a climate band, not your own roof |
Method & assumptions
Annual output and use are first allocated to months by typical profiles. For each month: self-consumed = min(consumption, production × direct share); import = consumption − self-consumed; export = production − self-consumed.
Net metering bills import − export − banked credit in kWh. If the result is positive it is charged at the nettable price. If negative, it is banked, paid or forfeited as your rule dictates, and December's remaining balance is settled at the true-up rate. Net billing works as credit = carried credit + export × export price, then bill = fixed + max(0, import × price − credit). Feed-in gives bill = fixed + import × price − export × feed-in price. Savings use the same household without solar as the benchmark.
Frequently asked questions
How does net billing differ from net metering?
When does the true-up happen in net metering?
Net metering versus a feed-in tariff, which is better for a home owner?
Should I build a system bigger than my consumption under net metering?
Is a battery worth adding to a net metering setup?
What is the non-nettable percentage?
Sources & references
Embed this calculator
Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.