On paper a small turbine is the ideal companion to rooftop solar, since it generates after dark and through winter when panels do little. At a good site that is exactly what happens. At a bad one, which covers most suburban gardens and almost every roof, it delivers a fraction of the brochure promise and never earns back its price. What separates the outcomes is the average wind speed where the rotor turns. This guide covers estimating that speed, the energy a turbine truly delivers, the money involved, and the choice between wind, solar or both.
Why a little more wind means a lot more power
The cube of wind speed sets the power available, so a halved speed leaves one-eighth. Nothing else in the home energy toolbox punishes a weak site as severely.
| Mean wind speed at hub | Relative energy (5 m/s = 100%) | Typical setting |
|---|---|---|
| 3.5 m/s | ≈ 30–35% | Suburban garden, rooftop |
| 4.5 m/s | ≈ 70–75% | Semi-open farmland, short tower |
| 5.0 m/s | 100% | Open farmland, 20–30 m tower |
| 6.0 m/s | ≈ 160–170% | Exposed rural site, coastal |
| 7.0 m/s | ≈ 240–260% | Hilltop, island, open coast |
Treat the percentages as approximate: real turbines do not follow a strict cube law along the whole power curve, and wind distributions differ between sites. What matters is the scale of the difference. At 6 m/s a turbine makes about five times what the same machine makes at 3.5 m/s.
Height raises wind speed
Terrain, trees and buildings drag on the air close to the ground. Going upward, speed increases on a roughly logarithmic curve that engineers usually approximate with a power law.
Take farmland (α ≈ 0.2): a rotor lifted from 10 m to 30 m meets about 25% faster wind and gets roughly 95% more power. For that reason a tall tower is normally the smartest spend in a small wind system. If you would rather not do the arithmetic, the wind speed at height calculator handles the power law and the log law, including surface roughness classes.
Turbulence does the quiet damage
Beside buildings and trees, air does more than slow down: it gusts, and both its direction and speed shift every few seconds. A turbine that keeps swinging round to chase it often points the wrong way, and gusts load blades and bearings much harder than a steady breeze. Output drops and parts wear out sooner.
One rule dominates siting, and it comes from the US Department of Energy’s Small Wind Guidebook: keep the lowest point of the rotor 9 m (30 ft) or more above anything within 150 m (500 ft). Roof mounts almost never meet that, and they also send vibration and noise through the building.
Realistic annual output
A turbine’s rated power refers to 11–12 m/s winds, which most places get for a few percent of the year at best, so annual energy cannot be read from it. Look instead at:
- Rated annual energy, stated for a 5 m/s mean (Rayleigh distribution) in certification schemes like AWEA/SWCC 9.1 and IEC 61400-2.
- Swept area, because energy follows rotor area much more closely than generator size.
A rough estimate needs only swept area and mean wind speed:
Three things are folded into that shortcut: air density (1.225 kg/m³), the energy pattern factor of a Rayleigh wind distribution (EPF ≈ 1.9, since strong winds carry an outsized part of the energy), and a system-wide power coefficient of about 0.15–0.25 for small turbines once generator, inverter and controller losses are counted. Certified machines of good quality land near the top of the range at 5 m/s. Beyond roughly 6.5 m/s it overstates, because the turbine then spends more hours held at rated power. Crude as it is, it punctures inflated brochure claims straight away. Run it on a 1 kW turbine with a 2 m rotor (3.1 m²) at a 4 m/s site and the answer is only about 300–500 kWh a year, whatever the label claims.
Worked example: 5 kW on a farm
A farmhouse stands in open country, where measurements or an atlas give a mean of 5.0 m/s at 10 m. The candidate is a 5 kW horizontal-axis turbine with a 5.5 m rotor, mounted on a 24 m tilt-up tower.
- Hub-height wind: farmland, α ≈ 0.2 → v(24) = 5.0 × (24/10)^0.2 ≈ 5.0 × 1.19 ≈ 5.95 m/s.
- Swept area: π × 2.75² ≈ 23.8 m².
- Yearly yield by the shortcut: 1.5–2.5 × 23.8 × 5.95³ ≈ 1.5–2.5 × 23.8 × 211 ≈ 7,500–12,500 kWh/yr at certified performance.
- Reality check: availability, icing, leftover turbulence and cabling usually remove another 10–20%, leaving roughly 6,500–10,500 kWh/yr.
- Capacity factor: 6,500–10,500 ÷ (5 kW × 8,760 h) ≈ 15–24%.
Compare a 12 m tower beside the house, trees 40 m away. Wind there is probably 4 m/s and turbulent. That gives 2,300–3,800 kWh/yr by the shortcut, and turbulence can cut a further 20–40% from it.
| Scenario | Hub wind | Annual energy | Value at €0.30/kWh |
|---|---|---|---|
| 24 m tower, open site | 5.95 m/s | 6,500–10,500 kWh | €1,950–3,150 |
| 12 m tower near trees | ≈ 4 m/s | 1,400–3,000 kWh | €420–900 |
| Rooftop, suburban | ≈ 3 m/s | 200–800 kWh | €60–240 |
The wind turbine calculator will model your own site using genuine power curves plus Weibull wind statistics from satellite data for any location.
What a turbine costs and whether it repays
Watt for watt, small wind is far dearer than solar. Tower, foundation, crane or gin-pole erection and grid connection cost about the same whatever the turbine size. Typical installed prices in Europe and North America look like this:
| Turbine size | Typical installed cost | Cost per kW |
|---|---|---|
| 1–2 kW (battery charging, off-grid) | €4,000–10,000 | €3,000–6,000 |
| 5–6 kW (farm / rural home) | €20,000–40,000 | €4,000–7,000 |
| 10–20 kW (farm, small business) | €50,000–110,000 | €4,000–6,000 |
Servicing covers annual inspections, bearing and brake checks and now and then a new blade or inverter, and typically costs 1–3% of capital a year. Designed life is 15–25 years for a well-maintained machine, less where turbulence is heavy.
Use the midpoint of the farm case: €30,000 installed, 8,000 kWh/yr at €0.30/kWh, and €500/yr for maintenance. Simple payback comes to 30,000 ÷ (2,400 − 500) ≈ 16 years, provided the wind estimate is right and the turbine lasts its design life. On the 12 m tower by the trees, savings barely cover upkeep and the money is never recovered. Spend the same €30,000 on rooftop solar in central Europe and you get roughly 15–25 kWp, perhaps 15,000–25,000 kWh/yr. The solar panel calculator lets you run that comparison for your roof.
Small wind pays chiefly where three conditions coincide: a hub-height mean above about 6 m/s, dear electricity or a pricey substitute such as diesel, and demand for the power on the spot.
Good fits for small wind
- Off-grid homes at high latitude. Wind in winter fills the gap left by weak sun, and in a hybrid system a 1–3 kW turbine can cut the hours a generator runs. Details are in the off-grid solar guide and the off-grid solar calculator.
- Open farms, islands, coasts and uplands with unobstructed fetch in the prevailing wind direction.
- Telecom, monitoring and remote infrastructure where delivering diesel is costly.
- Boats and remote cabins using small 300–600 W battery-charging turbines.
Pre-purchase checklist
- Establish the wind resource. Start with the Global Wind Atlas (DTU/World Bank) or our Energy Explorer, remembering that atlases model open terrain and can overstate wind at sheltered sites. Before any large outlay, log 6–12 months of data from an anemometer at or near hub height.
- Demand certified performance. Look for IEC 61400-2 or SWCC/AWEA 9.1 certification, with a certified power curve and rated annual energy at 5 m/s.
- Read the planning rules. Many places require permits above a given tower height and set boundary set-backs and noise limits. Small turbines typically produce 40–55 dB(A) at 30–60 m, depending on wind speed and design.
- Plan for access and servicing. Ground-level maintenance is possible with tilt-up towers; lattice towers need a trained climber.
- Model the alternatives. Compare spending the same budget on solar, insulation or a heat pump.
Vertical-axis and “bladeless” machines
Vertical-axis wind turbines (VAWTs), among them Savonius drums, Darrieus egg-beaters and helical types, are frequently sold for rooftops because they take turbulent wind from any direction. True, yet the physics stays put: wind near buildings is slow, and slow wind holds little energy. Most VAWTs also have lower power coefficients than three-bladed horizontal-axis rotors. Be wary of any small turbine promising high output in low wind, and ask for an independently certified power curve.
For wind at utility scale, read how wind turbines work, and browse national wind shares on the world energy map or in country profiles.
Calculators related to this topic
Frequently asked questions
How many kWh does a domestic wind turbine generate?
Are roof-mounted wind turbines any good?
What average wind speed justifies a home turbine?
Should I choose small wind or solar panels?
What tower height does a small turbine need?
Do vertical-axis turbines suit houses better?
Sources & references
The figures in this guide are typical ranges taken from the listed sources, and your own values will vary with location, prices and equipment. For estimates specific to your site, use the linked calculators.