Hydro & marine calculator

Tidal energy: barrage output and tidal stream turbine yield

Choose a tidal lagoon or barrage, described by basin area and tidal range, or tidal stream turbines, described by current speed and rotor size. The calculator then simulates a year through every spring–neap cycle to estimate yearly output.

Editable share link Branded PDF report Free · no sign-up

Results

Annual output is 13.6 GWh from 6 MW, at a capacity factor of 25.9%. You can predict it years in advance, yet it rises and falls with every tide and follows the spring–neap cycle. LCOE ≈ 422 €/MWh.
Annual energy
13.6GWh
3,785 average EU homes
Capacity factor
25.9%
2,271 full-load hours
Installed capacity
6MW
Average power
1.6MW
Rated current speed
3.13m/s
rotor 18 m · Cp 0.42
Average kinetic power density
4.67kW/m²
time-averaged ½ρ|u|³
Operating hours
6,457h/yr
640 h at rated power
LCOE
422€/MWh
capex 45 M€
Project IRR
-7.6%
at 200 €/MWh
Output over two weeks, spring to neap
  • Flow speed is modelled as u = U_peak(t)·sin(2πt/12.42 h). The peak itself moves sinusoidally from your spring value to your neap value across 14.77 days. Turbulence, the vertical velocity profile and any difference between flood and ebb are not included.
  • Enter the current at hub depth rather than at the surface. Wakes and blockage matter in large arrays, but this model treats each turbine on its own.

Two technologies, two models

The calculator handles the two quite different routes from tide to electricity.

Tidal range plants (barrages and lagoons) close off a basin at high tide. Once the sea has dropped far enough, the stored water runs through low-head turbines. It is hydropower with the Moon as the pump. The energy on offer grows with basin area and with the square of the tidal range.

Tidal stream machines stand in fast currents, rather like wind turbines under water. Rotor area and the cube of current speed set their output. Because seawater is some 840 times denser than air, an 18 m rotor in a 3 m/s current produces what a 70–80 m wind rotor does in 12 m/s wind. The catch is that strong currents are needed.

A lunar semi-diurnal cycle of 12.42 hours drives the tides, and a 14.77-day spring–neap cycle swells and shrinks them. The model runs one whole year. Barrages are stepped tide by tide and stream turbines every 10 minutes, while range or peak current slides between your spring and neap inputs.

Equations

Barrage / lagoon, per tide: E = ½ × ρ × g × A × R² Annual: E_year = Σ_tides min(E_tide × extraction factor, P_installed × generating hours) × availability

Tidal stream: P(t) = min(P_rated, ½ × ρ × A_rotor × Cp × |u(t)|³ × η) u(t) = U_peak(t) × sin(2π t / 12.42 h), U_peak varies between spring and neap over 14.77 days

Seawater density ρ is 1,025 kg/m³. Defaults for the extraction factor are 38% (ebb generation), 32% (flood) and 50% (two-way). It stands for turbine efficiency, the head required to start generating and the time spent waiting for it.

Example: four-turbine stream array

Presets: four 1.5 MW turbines, 18 m rotors, in a channel with depth-averaged peak currents of 3.5 m/s at springs and 1.8 m/s at neaps, close to phase one of MeyGen in Scotland’s Pentland Firth.

  • Using Cp = 0.42 and a 90% drivetrain, a turbine reaches rated power near 3.1 m/s.
  • Generation starts above 1 m/s, about 6,450 hours a year, but full power lasts only some 640 hours, mostly at spring tides.
  • Allowing 92% availability, annual output is about 13.6 GWh. That is a capacity factor close to 26% and supplies roughly 3,800 average EU homes.
  • At 7,500 €/kW and 3.5% O&M, LCOE is over €400/MWh, twice the assumed €200/MWh support price. This gap explains why tidal stream projects rely on dedicated contracts-for-difference and why cutting cost is the sector’s chief aim.

Loading the La Rance-type barrage preset (22 km², 11 m spring range, 5.5 m neap range, 240 MW, ebb generation) returns about 535 GWh a year. The real plant has delivered roughly 500 GWh over decades, so the model is in the right range.

Making sense of the output

  • Tidal plants usually reach a capacity factor of 20–40%, shown next to annual energy.
  • For stream sites, a lower rated current speed improves the capacity factor but wastes energy at springs, and developers balance this against cost.
  • For barrages, the per-tide chart reveals the spring–neap swing: energy scales with R², so a spring tide can give four times a neap tide.
  • A high share of tides limited by capacity means more turbines would harvest more.

Typical values

Parameter Tidal stream Tidal range
Resource needed spring peak current > 2.5 m/s mean range > 5 m
Unit size 0.1–2.5 MW 10–26 MW bulb turbines
Capacity factor 25–40% 20–30%
Capex 5,000–12,000 per kW 3,000–8,000 per kW
Example MeyGen (UK), 6 MW La Rance (FR) 240 MW; Sihwa (KR) 254 MW

Practical notes

  • Take measurements at hub height. Current slows toward the seabed, so rely on ADCP readings at rotor depth, not surface speed.
  • Watch both extremes of the cycle: strong springs paired with weak neaps yield less than the peak current implies.
  • A two-way lagoon produces on both flood and ebb, and it can pump at high water to raise the head, so its output is steadier than an ebb-only barrage.
  • Tidal output is predictable but arrives in four pulses daily, so it combines well with storage, wind and solar.

Limits of the model

The tide is represented by one sinusoidal constituent with spring–neap modulation. Real tides add diurnal inequality, equinoctial highs and flood/ebb asymmetry that varies by site. Each stream turbine is treated alone, with no wake or channel-blockage effects and no vertical velocity profile. For barrages, an empirical extraction factor replaces a full operating simulation, which limits accuracy to ±20–30%. Impacts on sediment, fish and intertidal habitats lie outside the model, although they are frequently what decides a barrage.

Method & assumptions

For tidal range plants (barrage or lagoon), a basin of area A that fills or empties through range R holds E = ½ ρ g A R² of potential energy, with ρ = 1,025 kg/m³. R varies from tide to tide, between neap and spring values, along a 14.77-day cycle, and a year's 706 tides are summed. An extraction factor converts this into delivered energy, and every tide is capped by installed power × generating hours. For tidal stream turbines, P = ½ ρ A Cp u³ η, held to rated power and set to zero below cut-in. The year is stepped through every 10 minutes using a sinusoidal M2 tide whose amplitude follows the spring–neap cycle. Finally LCOE = discounted costs ÷ discounted MWh.

Frequently asked questions

What formula calculates tidal energy?
It depends on the technology. For a barrage or lagoon, each tide stores E = ½ × ρ × g × A × R², built from seawater density, gravity, basin area and tidal range squared. For a stream turbine the relation is P = ½ × ρ × A × Cp × v³, the same form as a wind turbine's, with water roughly 840 times heavier than air.
What is the output of one tidal stream turbine?
A modern unit of 1.5–2 MW with an 18–20 m rotor hits rated power in a current near 3 m/s. Capacity factor typically lands at 25–40%, so a good site yields roughly 3,000–6,000 MWh a year.
Which current speeds make tidal stream worthwhile?
For commercial use, spring peak currents should exceed about 2.5 m/s, with 3–5 m/s ideal. With power rising as the cube of speed, a site at 4 m/s offers over twice the power available at 3 m/s.
What does the La Rance tidal station generate?
Operating in Brittany, France, since 1966, La Rance carries 240 MW of turbines. Its basin covers about 22 km² and the mean range is near 8 m. Annual output is roughly 500 GWh, which equals a capacity factor of about 24%.
Is tidal power predictable?
Very. The Moon and Sun drive the tides, which lets their timing and height be forecast years, even centuries, in advance. Generation does swing a lot over a day and across the 14.8-day spring–neap cycle, but the grid operator always knows what is coming.
What makes tidal energy costly?
Building at sea, corrosion, short weather windows for installation and servicing, and small project scale all push prices up. Tidal stream LCOE is today typically far above 200 per MWh (EUR or GBP), with falls expected as arrays get larger.

Sources & references

  1. Ocean Energy Systems (IEA Technology Collaboration Programme) — annual reports
  2. Charlier, R.H. (2007). Forty candles for the Rance River TPP tides provide renewable and sustainable power generation. Renewable and Sustainable Energy Reviews 11(9)
  3. Neill, S.P. & Hashemi, M.R. — Fundamentals of Ocean Renewable Energy, Academic Press, 2018
  4. IRENA — Tidal Energy Technology Brief (2014)

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.