Bypass diode
Diode connected across a section of cells in a PV module so string current can bypass shaded or damaged cells, which averts hot spots.
Every cell in a string must pass the same current. A shaded cell cannot generate it, so the other cells force it into reverse bias and it turns their power into heat. Such a hot spot can exceed 100–150 °C, harming the encapsulant and backsheet and sometimes starting a fire.
Bypass diodes stop this. A common module has three in its junction box, each guarding a substring of 20–24 cells (or two substrings in half-cut designs). Once shading drives a substring's voltage negative, its diode conducts and current flows around it.
- The bypassed substring adds nothing, so the module loses about a third of its power and voltage, while the remaining string keeps generating.
- Schottky diodes are chosen because their forward voltage is low, about 0.4–0.5 V, which limits heat in the junction box.
- A diode can fail open (no protection) or shorted (a substring is lost for good); thermal imaging and I-V curve tests reveal both.
When diodes conduct, the array's power-voltage curve gets several local maxima, so inverters need a global-scan MPPT routine to find the real peak. Half-cut modules divide into upper and lower halves working in parallel, which softens row-edge shading. Module-level electronics such as optimisers add to bypass diodes but do not take their place.
Related terms
All terms →- String (PV)
A series connection of PV modules, in which the voltages are added and the current equals that of one module.
- MPPT (Maximum Power Point Tracking)
Software in an inverter or charge controller that constantly tunes the operating voltage to pull the most power out of a PV array.
- Power optimizer
A DC-DC converter fitted to each panel, which hunts for that panel's maximum power point and conditions its output ahead of a string inverter.
- Microinverter
A compact inverter behind a single PV module or a pair of them, changing DC to AC right there and tracking the power point for each module separately.
- Soiling loss
Output lost when dust, pollen, bird droppings, snow or similar deposits block light on solar cells or mirrors.