Microinverter
A compact inverter behind a single PV module or a pair of them, changing DC to AC right there and tracking the power point for each module separately.
A microinverter converts DC to AC at the module itself. The array is therefore wired as parallel AC branches, not as high-voltage DC strings. Every unit runs its own MPPT, so a shaded, dirty or differently oriented module only hurts its own output. Enphase popularised the design in the late 2000s. Current units are rated about 250–500 VA per module, and dual- and quad-module versions exist.
Strengths:
- No string-level mismatch, which helps on complex roofs with several orientations or partial shade.
- DC voltage stays low (below about 60–80 V). That eases rapid-shutdown compliance under the US National Electrical Code (NEC 690.12) and reduces DC arc-fault risk.
- Monitoring per module, and you can add one panel at a time.
- Warranties often run 25 years, against 10–12 for string inverters.
Weaknesses:
- Cost per watt is higher, typically 0.15–0.30 USD/W above a residential string-inverter system.
- Weighted efficiency is about 96.5–97.5% (CEC), a little lower than big string units.
- Many electronic units sit in roof heat, and replacing one means getting onto the roof.
In the US, microinverters lead the residential PV market. They are also the norm in plug-in balcony systems in Germany, where 2024 rules allow units up to 800 VA on a household socket. On large, unshaded arrays, string inverters are still cheaper.
Related terms
All terms →- String inverter
A PV inverter that takes the DC from one or several module strings in series and delivers AC in step with the grid. It usually has multiple MPPT inputs that work independently.
- Power optimizer
A DC-DC converter fitted to each panel, which hunts for that panel's maximum power point and conditions its output ahead of a string inverter.
- MPPT (Maximum Power Point Tracking)
Software in an inverter or charge controller that constantly tunes the operating voltage to pull the most power out of a PV array.
- String (PV)
A series connection of PV modules, in which the voltages are added and the current equals that of one module.
- Bypass diode
Diode connected across a section of cells in a PV module so string current can bypass shaded or damaged cells, which averts hot spots.