Glossary · Grid & markets

Load factor

Average demand divided by peak demand over a period; it shows how evenly a customer or a power system uses electricity.

Load factor tells you how flat a demand profile is. At 100% demand never changes; the lower the figure, the sharper the peaks compared with average use.

Load factor = Energy consumed (kWh) / (Peak demand (kW) × Hours in period)

Take a commercial building that uses 438,000 kWh a year and peaks at 100 kW: 438,000 / (100 × 8,760) gives a load factor of 50%.

Common ranges:

  • Whole national systems: about 55 to 70%. The interconnected European system sits around 65 to 70%, and US systems that peak in summer on air conditioning are often lower.
  • Households: 20 to 40%, since evening peaks are brief.
  • Continuous industrial processes and data centres: 80 to 95%.

A higher load factor means fixed generation and network costs are shared across more kWh, so average supply cost falls. That is why many commercial and industrial tariffs have demand charges (per kW of peak), which reward customers who flatten their profile with storage, scheduling or demand response.

In the UK especially, people sometimes use the term for a generator's capacity factor. Strictly, load factor refers to demand, and capacity factor to generation output compared with nameplate.

Related terms

All terms →
  • Peak load

    The highest electricity demand a grid records over a given period; it fixes the capacity the system has to be able to deliver.

  • Baseload

    Lowest electricity demand seen on a grid across a day, season or year, historically met by plants running nonstop at high output.

  • Capacity factor

    Actual energy a power plant generates in a period divided by what it would generate at full nameplate capacity throughout that period.

  • Demand response

    Changes in end users' electricity use, prompted by price signals or operator requests, that help balance the grid.

  • Full-load hours

    Annual energy output expressed as the number of hours a plant would have to run at full rated power to produce it; equal to capacity factor times 8,760.

  • Power vs energy (kW vs kWh)

    Power in kW is the flow of energy at one moment, while energy in kWh is power added up over time. Capacity is stated in power, and output in energy.