Full-load hours
Annual energy output expressed as the number of hours a plant would have to run at full rated power to produce it; equal to capacity factor times 8,760.
Instead of a percentage, full-load hours (FLH, also called equivalent full-load hours; Volllaststunden in German) give yearly generation as a number of hours at nameplate power. You will meet them in European wind and solar statistics and in project finance spreadsheets.
Example: a 5 MW turbine that produces 15,000 MWh over twelve months logs 3,000 hours, which corresponds to a 34% capacity factor. With solar PV, the result is numerically the same as specific yield (kWh/kWp).
Rough benchmarks:
- Solar PV: 900–1,100 h in Germany, 1,600–1,900 h in southern Spain, above 2,800 h in the Atacama when trackers are used
- Onshore wind, Germany: about 1,600–2,200 h as a fleet average; modern low-specific-power turbines on good sites reach 2,500–3,200 h
- Offshore wind, North Sea: 3,500–4,500 h
- Nuclear: 7,000–8,000 h
The appeal is easy arithmetic. Multiply capacity by hours: a 10 MW solar park with 1,000 h yields roughly 10 GWh annually. Read quoted values with care, though. Ask whether the capacity is AC or DC, whether losses and curtailment are deducted, and whether the figure is for year one or an average over the plant's life, as degradation lowers it gradually.
Related terms
All terms →- Capacity factor
Actual energy a power plant generates in a period divided by what it would generate at full nameplate capacity throughout that period.
- Specific yield
Yearly energy a PV system produces per unit of installed capacity, in kWh/kWp per year. It reflects both the solar resource and how well the system performs.
- Peak sun hours
A day's solar irradiation restated as hours at 1,000 W/m²; its number is the same as kWh/m² per day.
- Power curve
How a turbine's electrical output depends on wind speed at hub height; with a wind speed distribution it yields an estimate of yearly energy production.
- Load factor
Average demand divided by peak demand over a period; it shows how evenly a customer or a power system uses electricity.