Glossary · Solar

String inverter

A PV inverter that takes the DC from one or several module strings in series and delivers AC in step with the grid. It usually has multiple MPPT inputs that work independently.

Homes, businesses and, more and more, utility-scale plants rely on string inverters as their usual PV conversion design. One unit connects to one or more strings, tracks the maximum power point and converts the DC into single- or three-phase AC.

  • Ratings: about 1.5–10 kW single-phase for homes, 10–125 kW for commercial sites, and 200–350 kW for utility string models at 1,500 V DC.
  • Efficiency: 98–99% at peak; 97–98.5% on the weighted European or CEC scale.
  • MPPT inputs: commonly 2–12, so roof faces or rows pointing in different directions work separately.
  • Design life: 10–15 years, which is why most home financial models include one replacement during a 25–30 year system life.

Module-level devices (microinverters, power optimisers) cost more per watt. String inverters typically cost less (often 0.05–0.15 USD/W for large units) and any fault is in one box within reach, though partial shading mismatches hit them harder. In large plants the alternative is a 1–5 MW central inverter; string designs spread the risk, ease maintenance and reduce losses when a unit fails.

A hybrid string inverter has a battery port for DC-coupled storage, able to save energy that would be lost to clipping. Current models also deliver grid-support functions demanded by codes such as IEEE 1547-2018 and EN 50549, like reactive power control and frequency-watt response.

Related terms

All terms →
  • String (PV)

    A series connection of PV modules, in which the voltages are added and the current equals that of one module.

  • Microinverter

    A compact inverter behind a single PV module or a pair of them, changing DC to AC right there and tracking the power point for each module separately.

  • Power optimizer

    A DC-DC converter fitted to each panel, which hunts for that panel's maximum power point and conditions its output ahead of a string inverter.

  • MPPT (Maximum Power Point Tracking)

    Software in an inverter or charge controller that constantly tunes the operating voltage to pull the most power out of a PV array.

  • DC/AC ratio

    The inverter loading ratio (ILR): the array's STC nameplate DC capacity relative to the inverter's AC rating.

  • Inverter clipping

    Energy lost when a PV array can produce more DC power than the inverter's AC rating, so the inverter limits output to its maximum.