Peak sun hours

A day's solar irradiation restated as hours at 1,000 W/m²; its number is the same as kWh/m² per day.

Sunlight changes through the day, so peak sun hours (PSH) give a simpler picture: the whole day's energy, expressed as the number of hours the sun would need to shine at the reference irradiance of 1,000 W/m². A site that receives 5 kWh/m² has 5 peak sun hours. How long the sun was actually up, 10 hours or 14, makes no difference.

PSH = H (kWh/m²/day) / 1 kW/m²     Eday (kWh) ≈ P (kWp) × PSH × PR

Modules are rated at the same 1,000 W/m² (STC), which makes quick estimates easy for installers. For instance, 6 kWp with 4.5 PSH and a performance ratio of 0.8 gives about 21.6 kWh a day.

Yearly averages, on a plane tilted for the best yield:

  • UK, Netherlands, northern Germany: about 2.8–3.2
  • Northern Italy, central US: 3.8–4.5
  • Southern Spain, Southwest US, northern India: 5–6
  • Atacama, Sahara, Arabian Peninsula: 6–7.5

Seasons matter more than the annual mean when you size an off-grid system or its battery. At 52° N, a December day can have less than 1 PSH and a June day more than 5. Designers usually plan around the weakest month.

Related terms

All terms →
  • Irradiation (insolation)

    Solar energy per unit area accumulated over a period, usually in kWh/m² per day or year; it is irradiance integrated over time.

  • GHI (Global Horizontal Irradiance)

    The total shortwave solar radiation reaching a horizontal surface, made up of the direct beam plus the diffuse light from the sky.

  • Performance ratio

    Actual AC energy delivered divided by the theoretical output given plane-of-array irradiation and nameplate capacity; a quality measure for PV plants that does not depend on location.

  • Specific yield

    Yearly energy a PV system produces per unit of installed capacity, in kWh/kWp per year. It reflects both the solar resource and how well the system performs.

  • Kilowatt-peak (kWp)

    How a PV module or array is rated in DC watts at Standard Test Conditions, and the customary measure of installed solar capacity.