Actual AC energy delivered divided by the theoretical output given plane-of-array irradiation and nameplate capacity; a quality measure for PV plants that does not depend on location.

The performance ratio (PR) is set out in IEC 61724-1. It scales a PV system's output by the solar resource that actually reached it, so you can judge the technical quality of plants in different climates side by side.

PR = Yf / Yr = [EAC / PSTC] / [HPOA / GSTC]

The final yield Yf is in kWh per kWp. The reference yield Yr is plane-of-array irradiation (kWh/m²) over 1 kW/m², which equals peak sun hours. With a PR of 0.82, 18% of the theoretical STC energy never reaches the output.

Normal ranges are 80–88% for well-designed modern utility plants, 75–85% for residential rooftops and 60–75% for older or badly maintained systems. Where the sun is strong, the largest loss items are:

  • Cells running hotter than 25 °C: 4–10% (see temperature coefficient)
  • Soiling: 1–5%
  • Inverter conversion: 1.5–3%
  • DC and AC cabling, mismatch: 1.5–3%
  • Shading, reflection, low-irradiance and spectral effects: 2–5%
  • Clipping and availability: 0–3%

Hot climates and summer months pull PR down, while cool, sunny conditions lift it a little. In O&M contracts a temperature-corrected PR is common, which stops the weather from counting against the guarantee.

Related terms

All terms →
  • Specific yield

    Yearly energy a PV system produces per unit of installed capacity, in kWh/kWp per year. It reflects both the solar resource and how well the system performs.

  • Temperature coefficient

    How much a PV module's power, voltage or current changes, in percent, for each degree Celsius its cells sit above or below 25 °C.

  • Soiling loss

    Output lost when dust, pollen, bird droppings, snow or similar deposits block light on solar cells or mirrors.

  • Peak sun hours

    A day's solar irradiation restated as hours at 1,000 W/m²; its number is the same as kWh/m² per day.

  • Inverter clipping

    Energy lost when a PV array can produce more DC power than the inverter's AC rating, so the inverter limits output to its maximum.