Glossary · Hydro & ocean

Pelton turbine

An impulse turbine for hydro power: fast jets of water hit double-cupped buckets around a wheel. It is the standard pick when the head is above roughly 250 m.

The Pelton wheel dates to Lester Pelton's 1880 patent. Its nozzles turn the pressure of a high-head water column into fast free jets, one or several. These strike split buckets. A central ridge in each bucket cuts the flow in two and reverses it by about 165–170°, which transfers almost the entire momentum of the jet. Because the runner turns in open air at atmospheric pressure, it differs from reaction turbines.

Head fixes the jet velocity, and the best efficiency occurs with bucket speed near half of jet speed:

vjet ≈ Cv √(2 g H),   ubucket ≈ 0.46–0.47 vjet

At a head of 1,000 m, the jet reaches about 135–140 m/s.

  • Head: from about 50 m (micro-hydro) to nearly 1,900 m, as at Bieudron in Switzerland (3 × 423 MW at about 1,880 m)
  • Efficiency at best point: 90–93% for large units
  • Partial flow: the curve is very flat, because nozzles close one at a time and spear valves throttle each jet. A vertical six-jet unit still performs well at about 10–20% of rated flow.

For safety against water hammer in long penstocks, deflectors can steer the jet away in a fraction of a second while the spear shuts slowly. You will find Pelton wheels in Alpine, Norwegian, Andean and Himalayan plants, and in off-grid micro-hydro, where a small wheel on a steep stream can light a village. Sediment scouring the buckets and needles is the main wear issue on glacial rivers.

Related terms

All terms →
  • Hydraulic head

    Vertical distance from the water level at a hydropower intake down to the turbine outlet (tailwater); multiplied with flow, it fixes the power on offer.

  • Francis turbine

    A reaction hydro turbine with fixed blades, where water flows in radially and out axially; the most installed design, suited to medium heads of about 30 to 700 m.

  • Kaplan turbine

    Propeller-type reaction turbine for hydro plants; both its runner blades and its wicket gates can be adjusted, so it suits low heads (about 2 to 40 m) and high flows.

  • Run-of-river hydro

    Hydro generation that takes water from a river's natural flow with hardly any reservoir, so output rises and falls with the river and not with demand.

  • Pumped hydro storage